P30
No RFID
With RFID
1)
MID (Measuring Instruments Directive): Measuring Instruments Directive
Example:
Value 304111:
The charging station has the following type and features:
●
●
●
●
●
3.9
1018 - Firmware version
Note: In P30 Modbus TCP version 1.11, this register's number is 1013.
This register contains the firmware version of the charging station. The rep-
resented value is in decimal and has to be converted to hex in order to read
the firmware version.
1018
Example:
Value 50990336 converted to hex = 30A0D00, which means firmware ver-
sion 3.10.14 (0A=10, 0D=14).
3.10
1020 - Active power
This register contains the active power in milliwatts.
Unit: mW
1020
Example:
Value 98661: The active power of the charging station is 98661 mW =
98.661 W.
Modbus TCP Programmers Guide V1.02
© KEBA
Type and
Product
features
type
KC-P30
32 A
c-series
standard energy meter, not calibrated
with RFID
Index
Firmware
Index
Active Power
Sup-
Cable /
ported
Socket
current
Name
Name
Readable Data
Device
Energy
Autho-
series
meter
rization
0
1
Type
UINT32
Type
UINT32
Attr.
ro
Attr.
ro
12