  • Page 1 KeContact P30 x-series Charging station Configuration manual V 4.01 Translation of the original manual...
  • Page 2 Specifications are subject to change due to further technical developments. Details presented may be subject to correction. All rights reserved. Gewerbepark Urfahr, 4041 Linz, Austria, Telefon: +43 732 7090-0, KEBA AG Headquarters: Fax: +43 732 7309-10, keba@keba.com For information about our subsidiaries please look at www.keba.com.
  • Page 3 Main menu ..................4.3.2 User menu ..................Enabling the DHCP server................Configuration in series via USB stick ............... Functions ........................Load management in the local charging network ..........5.1.1 Equal allocation mode ............... 5.1.2 Current limiting................... Configuration manual V4.01 © KEBA...
  • Page 4 Supported meters ................5.5.3 Settings ....................Diagnosis and troubleshooting ................Maintenance........................ Software update....................7.1.1 Software update via web interface............. 7.1.2 Software update via USB stick (x-series only) ........7.1.3 Software update via OCPP backend ..........Index ..........................Configuration manual V4.01 © KEBA...
  • Page 5: Introduction

    Caution means that damage to property can occur if the corresponding safety mea- sures are not taken. This symbol reminds you of the possible consequences of touching electro- statically sensitive components. Configuration manual V4.01 © KEBA...
  • Page 6: Purpose Of The Document

    Electrician ● the displays and operating elements of the charging station, ● basics of network technology, ● diagnostic options, ● systematic fault analysis and rectification, ● the setting options on the charging station. Configuration manual V4.01 © KEBA...
  • Page 7: Intended Use

    Guarantee Only the maintenance work expressly permitted by KEBA may be performed. Any other manipulations to the device will also result in loss of warranty. Only the covers described in the instructions may be opened. If one of the covers is sealed by a lead seal, it is not permitted to be opened by unautho- rized persons.
  • Page 8: Notes On This Document

    1.6.1 Contents of the document ● P30 x-series Charging station ● Commissioning of the charging station ● Configuration of the charging station Configuration manual V4.01 © KEBA...
  • Page 9: Not Contained In This Document

    Operating behavior of the charging station ● Operation of the charging station ● Troubleshooting Further documentation Manuals and additional information are available in the download area on the KEBA website: https://www.keba.com/en/emobility/service-support/downloads/Downloads Designation Target group ● End customer Operating instructions ●...
  • Page 10: Safety Instructions

    ● Never clean the charging station with aggressive solvents and cleaning products, scouring materials, water jets (e.g. garden hose, pressure cleaner etc.) or excessive pressure. Configuration manual V4.01 © KEBA...
  • Page 11: System Overview

    Only P30 x-series can be operated as master charging stations; only P20/30 c-series can be operated as slave charging stations. The following chapters describe which network interfaces the P30 x-series (master charging station) provides and how to set up a master/slave net- work. Configuration manual V4.01 © KEBA...
  • Page 12: Network Interfaces

    Internet. Connection: Ethernet1 connection (LSA+ ® Via the LAN interface, the P30 x-series charging station can also be con- nected to other charging stations, whereby a charging network can be real- ized. Configuration manual V4.01 © KEBA...
  • Page 13: Wlan

    WLAN. A charging station that is part of a charging network (master/slave network) must always be connected to the router via LAN. Otherwise, there may be data transmission errors (e.g. faulty software update) between the master charging station and the slave charging stations. Configuration manual V4.01 © KEBA...
  • Page 14: Wlan Access Point (Wlan Hotspot)

    Certain device variants have a GSM module. A P30 x-series charging station with GSM can connect to an OCPP backend over the cellular network. The mobile communications provider may charge additional fees (depending on the tariff) for running data transmissions. Configuration manual V4.01 © KEBA...
  • Page 15 (wire scraps, ...) passes through the SIM insertion slot into the inside of the charging station. 1) If still present, remove the indicated sticker above the SIM insertion slot. 2) Lightly press the SIM card into the slot until the spring mechanism locks. Configuration manual V4.01 © KEBA...
  • Page 16: Design Of A Local Charging Network (Master/Slave)

    The slave charging stations are connected to the master charging station via a router or switch. To enable communication between master and slave charging stations, the charging stations must be configured in the web interface, see 4 Configura- tion. Configuration manual V4.01 © KEBA...
  • Page 17: Displays And Signals

    ... P30 x-series (master) ... P20/P30 c-series (slave) In this case, the master charging station must be configured as a DHCP server. The IP address is then assigned to the slave charging station by the master charging station. Configuration manual V4.01 © KEBA...
  • Page 18: Connection Via Router Or Switch

    DHCP server), the IP addresses must not be in the following range: 192.168.25.xxx Using a switch For a network connection using a switch, the master charging station must be configured as a DHCP server. The IP addresses are then assigned by the master charging station. Configuration manual V4.01 © KEBA...
  • Page 19: Ports For Communication In The Charging Network

    Transfer of the software update Within the network (Bootps) Transfer of the software update Within the network (Bootps) Transfer of the software update Within the network (Bootps) Transfer of the software update Within the network (Bootps) Configuration manual V4.01 © KEBA...
  • Page 20: Configuration

    ... Status LED ... Enable input ... Switch contact output ... Ethernet2 connection (RJ45) ... Ethernet1 connection (LSA+®) ... Slot for SIM card (GSM module is ... USB interface optional) ... Ground for Ethernet1 connection Configuration manual V4.01 © KEBA...
  • Page 21: Dip Switch Settings

    Changes to the DIP switch settings only become effective after a restart of the charging station! To restart, press the "Service button" until the first signal tone sounds (ap- prox. 1 second) or switch off the charging station for a short time via the line circuit breaker. Configuration manual V4.01 © KEBA...
  • Page 22: Configuration Via Web Interface

    The configuration label is in a pouch which is enclosed with the mounting material. For security reasons, change the password after the ini- tial login. Illustration 4-7: Configuration label After successful login, the start page of the web interface opens. Configuration manual V4.01 © KEBA...
  • Page 23: Main Menu

    The scope of the displayed information is variant-dependent. System The area offers the following options: ● Software-Update ● GSM Signal Test ● Logging ● Restart System Configuration manual V4.01 © KEBA...
  • Page 24 Charging Parameters ● Network Connection ● WLAN / WiFi Access Point ● Proxy ● OCPP ● External TCP Meter ● Display Text Information The settings made are only applied after the "Apply" button has been pressed. Configuration manual V4.01 © KEBA...
  • Page 25 The WLAN access point can be configured here and enabled or disabled as required. Proxy All the necessary configurations for using a proxy server can be found in this part. OCPP All the necessary configurations for connecting to an OCPP backend can be found in this part. Configuration manual V4.01 © KEBA...
  • Page 26: User Menu

    The DHCP server of the master charging station is deactivated in the deliv- ery state and can be activated via the configuration in the web interface. Configuration manual V4.01 © KEBA...
  • Page 27: Configuration In Series Via Usb Stick

    If the saved configuration is only valid for exactly one charging station, the serial number of the charging station must be added to the name of the saved configuration file. P30_[serial number].conf Configuration manual V4.01 © KEBA...
  • Page 28: Functions

    RFID card. The following chapters will first explain the displays and signals and then de- scribe the procedure for authorization using RFID. Configuration manual V4.01 © KEBA...
  • Page 29: Displays And Signals

    The charging station is waiting for authorization to enable a Flashing blue charging session. Authorization necessary, either with RFID (every 3 seconds) card or by an external input. Illuminated orange The RFID card is invalid. (once) Configuration manual V4.01 © KEBA...
  • Page 30: Rfid Authorization Without Ocpp Backend Connection

    2) Then hold the slave card to be programmed in front of the RFID reader within 10 seconds and wait for the signal tone. 3) Confirm the teach-in process by holding up the master card again within 5 seconds. The process is completed with a rising tone sequence. Configuration manual V4.01 © KEBA...
  • Page 31: Rfid Authorization With Ocpp Backend Connection

    If this function has been activated in the DIP switch settings, enabling a charging session will additionally require a correct signal on the enable input X1. Further informa- tion can be found in the "Installation Manual". Configuration manual V4.01 © KEBA...
  • Page 32: Ocpp Backend

    UDP protocol. This can be used, for example, for inte- gration into a SmartHome. For more information, see the "UDP Program- ming Guide", which is available in the download area on the KEBA website. Configuration manual V4.01...
  • Page 33: Integration Of External Meters

    This ensures that the domestic connection safety device is not overloaded, and that it is not always necessary to select a lower charging capacity than would be pos- sible with the vehicle and the installation. Configuration manual V4.01 © KEBA...
  • Page 34: Connection

    B-control EM300 LR Herholdt ECSEM113 Janitza B23 312-10J ECSEM114MID Janitza Additionally required: ProData 2 data logger Information Detailed information about the meter installation can be found in the instal- lation instructions of the meter manufacturer. Configuration manual V4.01 © KEBA...
  • Page 35: Settings

    Changes to the DIP switch settings only become effective after a restart of the charging station! To restart, press the "Service button" until the first signal tone sounds (ap- prox. 1 second) or switch off the charging station for a short time via the line circuit breaker. Configuration manual V4.01 © KEBA...
  • Page 36: Diagnosis And Troubleshooting

    Diagnosis and troubleshooting P30 x-series Diagnosis and troubleshooting The FAQs on the KEBA website help to rectify possible errors that might oc- cur: https://www.keba.com/en/emobility/service-support/faqs/faqs-electricians- service-technicians Configuration manual V4.01 © KEBA...
  • Page 37: Maintenance

    (x-series). The master charging station relays the new firmware to the connected slave charging stations (c-series) via the software update. When connected to an OCPP backend, the software update for the entire charging network can also be performed via the OCPP backend. Configuration manual V4.01 © KEBA...
  • Page 38: Software Update Via Web Interface

    OCPP backend. To perform the software update an FTP link is required. The information downloaded from the KEBA website along with the software update contains the FTP link. For details on using the FTP link, see the OCPP backend manual.
  • Page 39: Index

    Settings.......... 35 Slave charging station ...... 16 Supported meters .......  34 Software update ........ 37 Switch ............ 18 GSM ............ 14 UDP interface ..........  32 LAN ............ 12 USB stick .......... 27 Load management ........ 28 Configuration manual V4.01 © KEBA...
  • Page 40 Index P30 x-series WLAN ............ 13 Web interface ..........  22 WLAN Access Point (Hotspot) .... 14 Configuration manual V4.01 © KEBA...
  • Page 42 98412 KEBA AG Headquarters Gewerbepark Urfahr 4041 Linz / Austria www.keba.com...

Table of Contents