3

Readable Data

This chapter describes all readable registers that are supported by KeCon-
tact P30.
3.1

1000 - Charging state

This register contains the state of the charging station.
1000
Supported values:
3.2

1004 - Cable state

This register contains the state of the charging cable.
1004
Supported values:
Modbus TCP Programmers Guide V1.02
© KEBA
Index
State
0: Start-up of the charging station
1: The charging station is not ready for charging. The charging station is
not connected to an electric vehicle, it is locked by the authorization
function or another mechanism.
2: The charging station is ready for charging and waits for a reaction
from the electric vehicle.
3: A charging process is active.
4: An error has occurred.
5: The charging process is temporarily interrupted because the tempera-
ture is too high or the wallbox is in suspended mode.
Index
Cable State
0: No cable is plugged.
1: Cable is connected to the charging station (not to the electric vehicle).
3: Cable is connected to the charging station and locked (not to the elec-
tric vehicle).
5: Cable is connected to the charging station and the electric vehicle (not
locked).
7: Cable is connected to the charging station and the electric vehicle and
locked (charging).