Intel® Raid Adapter Rs3P4Mf088F Electrical, Thermal, And Atmospheric Requirements; Intel® Raid Adapter Rs3P4Mf088F Power Consumption; Table 8. Intel® Raid Adapter Rs3P4Mf088F Consumption - Intel RS3P4TF160F Hardware User's Manual

Raid adapters
Table of Contents

Advertisement

Intel® RAID Adapters RS3P4TF160F and RS3P4MF088F Hardware User Guide
4.2.2
Intel® RAID Adapter RS3P4MF088F Electrical, Thermal, and Atmospheric Requirements
This is a list of the operating conditions for the Intel RAID Adapter RS3P4MF088F:
Power supply voltage at the 12 V rail (from PCI edge connector): 12V ± 8%.
Power supply voltage at the 3.3 V rail (from PCI edge connector): 13.3V ± 9%.
Relative humidity range is 20% to 80% non-condensing.
Temperature range is 0 °C to +55 °C (with or without the RMFBU Adapter attached).
The following list shows the non-operating conditions (while in storage or in transit) for the Intel RAID
Adapter RS3P4MF088F:
Relative humidity range is 5% to 90% non-condensing.
Temperature range is -45 °C to +105 °C without backup battery unit.
Temperature range is 0 °C to +70 °C with backup battery unit.
4.2.3
Intel® RAID Adapter RS3P4MF088F Power Consumption
The following table describes the power consumption of the Intel RAID Adapter RS3P4MF088F under the
following states:
State 1: While sitting idle at the DOS prompt or the EFI shell.
State 2: During a drive stress test; average over 20 minutes of sustained operation.
Table 8. Intel® RAID Adapter RS3P4MF088F Consumption
Power Mode
3.3 V supply
+ 12 supply
3.3 V auxiliary supply
Total power
State 1
State 2
Typical
Typical
RMFBU Learn
0.23 W
0.20 W
16.40 W
17.48 W
0.07 W
0.03 W
16.70 W
17.71 W
6 W
6 W
23