Extender Cable; Intel® Raid Maintenance Free Backup Unit Installation; Super Cap Assembly Into The Holder; Figure 16. Extender Cable Pinout - Intel RS3P4TF160F Hardware User's Manual

Raid adapters
Table of Contents

Advertisement

Intel® RAID Adapters RS3P4TF160F and RS3P4MF088F Hardware User Guide
8.2.1

Extender Cable

The extender cable has an 8-pin Molex 43020-0601* connector on one end and, on the other end, a 9-pin
Molex 501330-0900* connector. Two versions of the cable are included in the kit (one 605 mm long and the
other 930 mm long). The routing of the cable is shown in
8.3
Intel® RAID Maintenance Free Backup Unit Installation
The mounting hardware included with the Intel RAID Maintenance Free Backup AXXRMFBU7 accessory kit is
designed to be compatible for installation into a supported Intel pedestal and rack mount server system. An
alternate attachment method may be needed when installing this accessory into a non-Intel chassis.
Intel recommends using industrial-grade Velcro* or other industrial adhesive material as an acceptable option.
Refer to the server chassis documentation or discuss an appropriate attachment method with the server
chassis manufacturer to ensure that the attachment mechanism complies with the chassis requirements.
8.3.1

Super Cap Assembly into the Holder

The RMFBU plastic case needs to have the latch installed and the super cap bank needs to be assembled
with the RMFBU plastic case before attaching it on the mounting bracket.
1. Insert the latch in the opening on the plastic case (see Letter A).
2. Lift the latch holder slightly up (see Letter B) and insert the opening notch until it clicks (see Letter C).
3. Bring the latch down until it is aligned vertically (see Letter D).

Figure 16. Extender Cable Pinout

Figure 17. Latch Installation on the Plastic Case

Figure
16.
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs3p4mf088f

Table of Contents