Mean Time Between Failures (Mtbf) In The Intel® Raid Maintenance Free Backup Axxrmfbu7; Intel® Raid Maintenance Free Backup Unit Monitoring; Figure 21. Intel® Raid Maintenance Free Backup Axxrmfbu7 Connection To The Intel® Raid Adapter; Table 14. Mtbf Information Calculated At Different Temperatures For The Intel® Raid Maintenance Free Backup Unit - Intel RS3P4TF160F Hardware User's Manual

Raid adapters
Table of Contents

Advertisement

Intel® RAID Adapters RS3P4TF160F and RS3P4MF088F Hardware User Guide
Figure 21. Intel® RAID Maintenance Free Backup AXXRMFBU7 Connection to the Intel® RAID Adapter
8.4
Mean Time Between Failures (MTBF) in the Intel® RAID Maintenance Free
Backup AXXRMFBU7
The Intel RAID Maintenance Free Backup AXXRMFBU7 is extremely sensitive to temperature. Although the
heat produced by itself is negligible, the heat from other components located near this unit can affect it
significantly. The following table shows MTBF information calculated at different temperatures.
Table 14. MTBF Information Calculated at Different Temperatures for the Intel® RAID Maintenance Free
8.5
Intel® RAID Maintenance Free Backup Unit Monitoring
Three different utilities can be used to monitor the RMFBU: StorCLI, RAID Web Console 3, and the Human
Interface Infrastructure (HII). This section only describes how to use HII for this purpose. For details on how
to monitor using the other utilities, consult the Intel® RAID Utilities User Guide.
42
Intel® RAID Maintenance Free Backup AXXRMFBU7
Temperature (Celsius degrees)
MTBF (hours)
Backup Unit
55
40
10,152.28.
19,493,177.
30
28,169,014.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs3p4mf088f

Table of Contents