GR4000 Quick Start Guide, Revision 1 - Preliminary
system name GR1
(config)#
snmp "NETWORK-A" 192.168.1.2
!GR1(config)#
!GR1(config)#
line ethernet0/0 ethernet 0/0
[line ethernet0/0]
ip 192.168.1.1/24
!GR1(config)#
[line ethernet0/0]
exit
!GR1(config)#
!GR1(config)#
line ethernet1/0 10gigabit_ethernet 1/0
[line ethernet1/0]
ip 192.168.2.1/24
!GR1(config)#
[line ethernet1/0]
!GR1(config)#
exit
rip yes
!GR1(config)#
[rip]
interface 192.168.1.1
!!GR1(config)#
[rip interface 192.168.1.1]
exit
!!GR1(config)#
[rip]
interface 192.168.2.1
!!GR1(config)#
[rip interface 192.168.2.1]
!!GR1(config)#
exit
[rip]
exit
!!GR1(config)#
!!GR1(config)#
apply
!GR1(config)#
NOTE
The mark "!" will be shown at the beginning of a prompt if you change configuration information.
However, you can delete this mark by saving configuration information you changed. Likely, the
mark "!!" will be shown at the beginning of a prompt if you input the command which does not
need to be applied for operations immediately. In such a case, you can apply your settings for
operations immediately by inputting the "apply" command, after wich the mark "!!" will be
changed to "!".
NOTE
A device name you input will be shown at the beginning of a prompt.
32
...Input a device name.
...Input a name for SNMP Manager.
...Input a line name/IP address for an Ethernet port.
...Set RIP.
...Apply the RIP command you set.
QSGGR4K00-10 5794047-1X