Control commands for easy600
Byte
Meaning
M
S
Attribute ID
Read
0
Response
Read successful
Command
rejected
0
1
Status of inputs I1
to I8
1
2
State of the inputs
I9 to I16
2
3
State of the buttons
M
= master
S
= Slave
62

Digital inputs, P buttons and operating buttons

Using the following command the logical states of the digital
button inputs P1 to P4 as well as the logical states of the
digital inputs I1 to I16 can be read.
The status of the P buttons is only displayed if
• a P button is used in the circuit diagram and
• the pushbuttons are activated on the device.
Telegram structure
Value (hex), sent by
Master
Slave
5C
C2
C0
00
a table 18
00
a table 19
00
a table 20
09/10 MN05013007Z-EN
Bit
7 6 5 4 3 2 1 0
0 1 0 1 1 1 0 0
1 1 0 0 0 0 1 0
1 1 0 0 0 0 0 0