Sign In
Upload
Manuals
Brands
Eaton Manuals
Recording Equipment
EASY222-DN
Eaton EASY222-DN Manuals
Manuals and User Guides for Eaton EASY222-DN. We have
2
Eaton EASY222-DN manuals available for free PDF download: User Manual, Instruction Leaflet
Eaton EASY222-DN User Manual (284 pages)
DeviceNet Slave Interface
Brand:
Eaton
| Category:
Recording Equipment
| Size: 1 MB
Table of Contents
Table of Contents
5
About this Manual
11
List of Revisions
11
Target Group
11
Additional Device Manuals
11
References
12
Device Designation
12
Abbreviations and Symbols
14
Writing Conventions
14
The EASY222-DN
15
System Overview
16
Structure of the Unit
17
EASY222-DN Communication Profile
18
Hardware and Operating System Requirements
19
Improper Use
20
Installation
21
EASY222-DN Connection to the Basic Unit
21
Connecting the Power Supply
22
Connecting Devicenet
23
Terminal Assignment Devicenet
23
Terminal Resistors
24
EMC-Conformant Wiring of the Network
24
Potential Isolation
25
Data Transfer Rates - Automatic Baud Rate Detection
26
Maximum Distances and Bus Cable Lengths
26
Device Operation
27
Initial Starting
27
Devicenet Setting the Slave Address
28
Setting the Address by Means of Easysoft
30
Setting the Address Via the Master PLC
30
LED Status Indication
31
Module Status LED
31
Network Status LED
32
Cycle Time of the "Easy" Basic Unit
33
EDS File
33
Devicenet Functions
35
Object Model
35
Identity Object
39
Devicenet Object
41
Easy Object
42
Devicenet Communication Profile
45
I/O Messages
45
Explicit Messages
46
Direct Data Exchange with Easy/Mfd (Polled I/O Connection)
51
Input Data: Mode
53
Output Data: Mode
55
Control Commands for Easy600
59
Read and Write Date and Time, Summer and Winter Time
61
Read Image Data
65
General Information on Working with Image Data
65
Overview
65
Digital Inputs, P Buttons and Operating Buttons
66
Analog Inputs: I7 - I8
69
Timing Relays, Counter Relays, Timer Switch, Analog Value Comparator
70
Auxiliary Relay (Marker), Digital Outputs, Text Display
73
Read/Write Function Blocks
76
Overview
76
Analog Value Comparator A1 - A8: Write Actual Values (Function, Comparison Values)
77
Counter Relays C1 - C8: Read Actual Value
80
Counter Relay C1 - C8: Write Reference Value
82
Counter Relay C1 - C8: Read Reference Value
84
Timing Relays T1 - T8: Read Actual Value (Timing Range, Actual Value, Switching Function)
86
Timing Relays T1 - T8: Write Parameters (Timing Range, Reference Value,Switching Function)86
90
Ö Ö 4: Read Actual Value
94
Ö Ö
98
Ö 4: Read Setpoint Value
98
(Channel, on Time, off Time)
98
Control Commands for Easy700
103
Read/Write Date and Time
105
Read/Write Image Data
109
Overview
109
Read Marker: M1 - M16/N1 - N16
118
Operating Hours Counters: O1 - O4
120
Local P Buttons: P1 - P4
121
Local Outputs: Q1 - Q8
123
Inputs/Outputs of Easylink: R1 - R16/S1 - S8
124
Timers: T1 - T16
126
Year Time Switch: Y1 - Y8
127
Master Reset: Z1 - Z3
128
Weekly Timer
129
Ö Ö
129
Read/Write Function Block Data
130
General Notes
130
Overview
130
Analog Value Comparator/Threshold Comparator
131
Counter Relays: C1 - C16
134
Operating Hours Counters: O1 - O4
137
Timing Relays: T1 - T16
139
Weekly Timer
145
Ö Ö
145
Analysis - Error Codes Via Easylink
148
Easy800/Mfd Control Commands
149
Data Exchange Procedure
149
Version History
151
Read/Write Date and Time
152
Winter/Summer Time, DST
153
Read/Write Image Data
158
Overview
158
Local Analog Inputs: IA1 - IA4
159
Local Diagnostics: ID1 - ID16
161
Read Local Inputs: IW0
163
Inputs of the Network Station: IW1 - IW8
165
Marker: M
166
Local Analog Output: QA1
171
Local Outputs: QW0
172
Outputs of the Network Station: QW1 - QW8
172
Inputs/Outputs of Easylink: RW/SW
174
Read/Write Function Block Data
178
General Notes
178
Overview
179
Analog Value Comparator: A01 - A32
181
Boolean Operation: BV01 - BV32
189
Counter: C01 - C32
191
Frequency Counters: CF01 - CF04
193
High-Speed Counter: CH01 - CH04
195
Incremental Encoder Counters: CI01 - CI02
197
Comparator: CP01 - CP32
199
Text Output Function Block: D01 - D32
201
PID Controller: DC01 - DC32
206
Dg01
209
Signal Smoothing Filter: FT01 - FT32
211
Receipt of Network Data: GT01 - GT32
213
Comparator: CP01 - CP32
215
Year Time Switch: HY01 - HY32
218
Conditional Jump JC01
221
Value Scaling: LS01 - LS32
223
Data Multiplexer MX01
227
Numerical Converter: NC01 - NC32
229
Hours-Run Counter: OT01 - OT04
231
Pulse Width Modulation: PW01 - PW02
233
Value Scaling Function Blocks LS01 .. LS32
236
Pulse Width Modulation: PW01 - PW02
238
Synchronize Clock: SC01
240
Attribute ID Read
240
Instance
240
Serial Output SP01
241
Index
241
Data 1 - 4 Read Operation
241
Sending of Network Data: PT01 - PT32
243
Depending on Index
243
Set Cycle Time: ST01
246
Timing Relays: T01 - T32
248
Value Limitation: VC01 - VC32
251
Analysis - Error Codes Via Easylink
255
What Happens if
257
Appendix
259
Technical Data
259
Dimensions
262
EDS File
263
Glossary
267
Alphabetical Index
275
Advertisement
Eaton EASY222-DN Instruction Leaflet (3 pages)
Brand:
Eaton
| Category:
Relays
| Size: 0 MB
Advertisement
Related Products
Eaton PROFIBUS-DP EZ204-DP
Eaton ELC-GP02
Eaton ELC-GP04
Eaton ELC-CBPCGP3
Eaton ELC-PS01
Eaton ELC-PS02
Eaton Cutler-Hammer PanelMate ePro 7500 Series
Eaton EASY223-SWIRE
Eaton EASY200-EASY
Eaton EASY202-RE
Eaton Categories
UPS
Circuit breakers
Switch
Industrial Equipment
Industrial Electrical
More Eaton Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL