Summary of Contents for SafeWaze Northstar Classic FS-FSP1215-G
Page 1
Leading Edge (LE) FS9020 FS-FSP1420-W FS9030 FS-FSP1530-W FS9050 FS-FSP1550-W This manual is intended to meet the manufacturer’s instructions as required by ANSI Z359.14 and should be used as part of an employee training program as required by OSHA. Copyright Safewaze 2022 220-00067...
Use of this equipment for any other purpose, such as material handling, sports activities, or other action not described in these User Instructions is not approved by Safewaze. Use of this equipment in a manner outside the scope of those covered within this Manual can result in serious injury or death.
Page 3
SRL units extend and retract freely with normal movement. If a fall occurs the system locks automatically, arresting the fall, and keeps the worker from falling further. Tension should always be maintained on the lifeline during retraction of cable or web back into the housing. Never allow the lifeline to “freewheel” back into the housing in an uncontrolled manner. Page 3 Copyright Safewaze 2022...
Page 4
1.1 PURPOSE Safewaze Northstar Classic SRLs are designed for use as a component of a complete Personal Fall Arrest System (PFAS). The purpose is to prevent the fall or limit the potential fall arrest forces as much as possible. A variety of connection and configuration options are available to suit any users preference or jobsite requirements.
During normal operations, the lifeline constituent of the SRL will extend and retract freely with no slack or hesitation as the worker moves at normal speeds. In the event of a fall, Safewaze SRLs are equipped with a speed sensing braking system. The braking system will activate, stopping the fall, and absorbing much of the energy created by the fall.
Do not use equipment that is not compatible. Ensure all connectors are fully closed and locked. Safewaze connectors (snap hooks and carabiners) are designed to be used only as specified in each product’s user’s instructions. (See Figure 2) for examples of inappropriate connections.
Page 7
Only a Full Body Harness (FBH) may be used with this equipment. The Full Body Harness must connect to the SRL via the dorsal D-ring. Safewaze SRLs are not rated for use with a body belt. Use of Safewaze SRLs with a body belt may result in injury. Figure 3 illustrates typical connection of Safewaze SRLs to the Dorsal D-ring of the Full Body Harness.
Page 9
Average Arresting Force 900 lbf (4.0 kN) Claimed Maximum Arresting Distance 47 in (1.2 m) Minimum Fall Clearance Required 14.5 ft. (4.41 m) Maximum Free Fall 5 ft. (1.5 m) Minimum Setback Distance 3 ft. (0 m) Page 9 Copyright Safewaze 2022...
Page 10
Maximum Arresting Force 1,800 lbf (8.0 kN) Average Arresting Force 900 lbf (4.0 kN) Claimed Maximum Arresting Distance 54 in. (1.5 m) Minimum Fall Clearance Required 8.5 ft (2.05 m) Maximum Free Fall 0 ft. (0 m) Page 10 Copyright Safewaze 2022...
Page 11
Greater clearance is needed to ensure safety during a swing fall as vertical fall distance will be greater than a fall originating directly below the anchorage point. For help determining additional required fall clearance due to Swing Fall, (See Table 9). FIGURE 8 - SWING FALLS FALL-ARREST Page 11 Copyright Safewaze 2022...
5.0 USE WARNING: Contact Safewaze if you have questions regarding compatibility of this equipment that are not covered in this manual. Do not alter or misuse this equipment. Some subsystem components could affect the performance of the operation of this equipment.
Select an anchorage location with minimal free fall and swing fall hazards (See Section 2.0). Select a rigid anchorage point capable of sustaining static loads as defined in Section 2.0. Where anchoring overhead is not feasible, Safewaze SRLs may be secured to anchorage points below the level of the user’s dorsal D-ring, but never below the user’s feet.
Page 14
Inspect the SRL (using the Inspection Form on Page 17) before returning to service. 7.3 STORAGE Store Safewaze SRLs in a cool, dry, clean environment out of direct sunlight. Avoid areas where chemical vapors may exist. Thoroughly inspect the SRL after any period of extended storage.
Page 15
8.5 DISPOSAL Dispose of the Safewaze SRL if it has been damaged by fall arrest forces or inspection reveals an unsafe or defective condition that cannot be repaired by an authorized Safewaze Service Center. Before disposing of the SRL, cut the lifeline in half so that it is not mistakenly reused.
Page 16
Swivel Top Lifeline Label Housing (Cable) ANSI Z359.14, ANSI A10.32 OSHA 1910.66, OSHA 1926.502 Lifeline Swivel Fall (Cable) Indicating Snap Protective Hook Label Cover Additional LE Labeling Integral Energy Absorber Swivel Fall Indicating Snap Hook Page 16 Copyright Safewaze 2022...