Fire Prevention
Danger due to faulty or incorrect installation.
This may result in damage to inverters and other current-carrying parts of a
photovoltaic system.
Faulty or improper installation may cause overheating of cables and terminals as
well as the formation of arcs. This could cause thermal damage, which in turn
may lead to fires.
Please note the following when connecting the AC and DC cables:
Notice! Fronius will not bear any costs for production downtimes, or for installa-
tions, etc., which may arise due to a detected electric arc and its consequences.
Fronius accepts no liability for fires which may break out despite integrated arc
detection/interruption (e.g., due to a parallel arc).
Notice! Before an inverter can be reset following a detected electric arc, check
the entire affected photovoltaic system for any damage.
The manufacturer's specifications for connection, installation, and operation
must be observed. You must carefully follow all installation steps and make all
connections in accordance with specifications and regulations to minimize any
risk of danger.
The tightening torques for the respective terminals are listed in the Installation
Instructions for the devices.

Intended Use

The inverter is designed exclusively to convert direct current from solar modules
into alternating current and feed this power into the public grid.
The following are deemed to be not in conformity with its intended purpose:
-
-
-
The manufacturer is not responsible for any damage resulting from improper use.
All warranty claims are considered void in such cases.
Proper use also means
-
-
-
CAUTION!
Securely tighten all terminals using the proper torque listed in the Operating
Instructions
Securely tighten all grounding terminals (PE/GND) using the proper torque
listed in the Operating Instructions, even for free grounding terminals
Do not overload cables
Check cables for damage and correct wiring
Follow all safety instructions, Operating Instructions, and any local connec-
tion regulations
Always secure the inverter to the mounting bracket with fixing screws using
the torque specified in the Operating Instructions.
Only put the inverter into operation with the fixing screws securely tightened.
Utilization for any other purpose, or in any other manner
Alternations to the inverter are not expressly recommended by Fronius
Installation of components that are not expressly recommended or sold by
Fronius.
carefully reading and obeying the instructions and all the safety and danger
notices in the Operating and Installation Instructions
compliance with the maintenance operations
installation as specified in the Installation Instructions