Elation Artiste Van Gogh EAV259 User Manual page 22

Table of Contents

Advertisement

S Y S T E M M E N U
PERSONALITY – Service Setting – USB Update
To update the fixture software via the UPDATE/SERVICE PORT, follow steps below.
ONLY QUALIFIED TECHNICIANS SHOULD PERFORM THIS FUNCTION!
NOTE ALL MENU SETTINGS BEFORE UPDATING SOFTWARE!
FIXTURE SOFTWARE CAN NOT BE DOWNGRADED!
DOWNLOAD FIXTURE SOFTWARE TO PC ONLY! (NO MAC SUPPORT)
PLEASE CONTACT ELATION SERVICE FOR FURTHER INFORMATION.
1. Copy fixture software update file from a PC computer to a compatible USB flash drive.
2. Make sure only the fixture software update file is stored on the USB flash drive.
3. Disconnect DMX, Art-Net, and E-FLY connections and power the fixture ON.
4. Insert USB flash drive into the UPDATE/SERVICE PORT on the rear connection panel.
5. Navigate to the Personality main menu Service Setting / USB Update sub menu.
6. Select the software file name on the menu display and press ENTER.
7. Select YES to begin update process and
8. After file is uploaded, the fixture will check the software which will take some time.
9. The fixture will perform a reset process when the software update process is complete.
10. Remove the USB flash drive and make necessary system menu setting adjustments.
PERSONALITY - Display Setting – Key Lock
When ON, Control Panel buttons lock automatically after exiting main menu for 15 seconds. To unlock,
keep MODE/ESC button pressed for 3 seconds.
PERSONALITY - Reset Default (011)
ONLY QUALIFIED TECHNICIANS SHOULD PERFORM THIS FUNCTION!
This function restores all fixture settings to the factory default settings. The password is 011 and must
be entered each time a reset is performed.
EFFECT ADJUST – Test Channel
Auto test each individual channel function independently from the DMX control board.
EFFECT ADJUST – Manual Control
Select and manually test and fine adjust each individual channel function
Independently from DMX control board. This function will center PAN and TILT motors and set dimmer
to 100%. PAN and TILT functions will still operate if the fixture needs to be positioned to a flat clear
surface. With the individual functions, you can focus the light on a flat surface (wall) and perform fine
adjustments.
Updating...%
will show on the menu display.