Options; Connecting Your Machine To The Earth; Electricity/Air/Water Requirements And Installation - Lincoln Electric LINC-CUT S 1020w Instruction Manual

Table of Contents

Advertisement

Options

Marker

Connecting your machine to the earth

The machine must be connected to the earth appropriately to keep personnel safe and suppress high-
frequency noise. The foundation for satisfactory earthing is an effective earth rod. A ground point is connected
to the rod with a short, heavy conductor. A simple copper clad steel rod may be driven into the ground
to create an earth rod. An earth rod must be installed. Bring in a qualified electrician to verify the earth
connection of your system.
Use a 16² twisted cable to connect the earth rod on the table to the earthing connection provided by the
customer.
For proper operation of your CNC cutting tables, you need to connect a 16² cable from the earth connection
rod to the dedicated earth rod.
Put the plasma cutting unit
in its appropriate location.
Reinstall the power and earth
cables of the table at the front
of the machine.
The FLEXCUT
125 CE or
TM
1538 plasma
TOMAHAWK
®
cutting unit is supplied with
an earth connection attached
to the earth connection
bar. Further, a work earth
connection is attached to
the earth star to connect to
the cut material. If the work
piece is painted or dirty, you
may need to expose the
metal underneath for a good
electrical connection.
The earth rod is not supplied
with the machine

Electricity/air/water requirements and installation

Please refer to the instruction manual of the FLEXCUT
instructions for installation and operation. Only a qualified electrician may connect the input leads to the
S 1020w-1530w and the FLEXCUT
LINC-CUT
®
Connections are to be made in accordance with all local and national electrical requirements. Failure to do so
may result in injury or death.
The LINC-CUT
S 1020w-1530w is designed for an input voltage of 220/230 V, single phase, 50 or 60 Hz.
®
Before connecting the machine to the power supply, make sure that the voltage, phase and frequency of the
input current match those indicated on the name plate.
The FLEXCUT
125 CE or TOMAHAWK
TM
60 Hz. Before connecting the machine to the power supply, make sure that the voltage, phase and frequency
of the input current match those indicated on the name plate.
WARNING
The On/Off switch of the FLEXCUT
out device for the machine. Only a qualified electrician may connect the input leads to the LINC-CUT
1020w-1530w.
LINC-CUT
S 1020w-1530w
®
See "Marker installation and configuration" section
125 CE or TOMAHAWK
TM
125 CE or TOMAHAWK
TM
1538 is designed for an input voltage of 400 V, three phase, 50 or
®
125 CE or TOMAHAWK
TM
12
1538 for complete
®
1538 plasma cutting units.
®
1538 is not designed to be used as a cut-
®
S
®

Advertisement

Table of Contents
loading