Choosing An Installation Location - Graco G3-G-12NC-2L0000-00C00000 Instructions Manual

G3 series standard automatic lubrication pump
Hide thumbs Also See for G3-G-12NC-2L0000-00C00000:
Table of Contents

Advertisement

Choosing an Installation Location

AUTOMATIC SYSTEM ACTIVATION HAZARD
If the system is equipped with has an automatic timer
(user supplied) that activates the pump lubrication
system when power is connected or when exiting the
programming function, unexpected activation of the
system could result in serious injury, including skin
injection and amputation.
Before you install or remove the lubrication pump
from the system, disconnect and isolate all power
supplies and relieve all pressure.
Select a location that will adequately support
the weight of the G3 Pump and lubricant, as
well as all plumbing and electrical connections.
Refer to the mounting hole layouts provided in
the Mounting Pattern section of this manual,
page 35. No other installation configuration
should be used.
332291G
Use designated mounting holes and provided
configurations only.
Always mount the G3 oil models upright.
If the G3 grease model is going to be operated
in a tilted or inverted position for any period of
time, you must use a model that includes a fol-
lower plate, otherwise the G3 must be mounted
upright. Refer to your model number to confirm
if a follower plate was installed on your pump.
See page 4, Understanding the Model Number
to identify this character in your model number.
Use the three fasteners (included) to secure the
G3 to the mounting surface.
Some installations may require an additional
reservoir support bracket. See Table below for
bracket information
Part No Description
571159 Reservoir bracket and strap
125910 L-Bracket for pump
127665 USP to G-Series mounting bracket
Installation
11

Hide quick links:

Advertisement

Table of Contents
loading