Download Print this page

mr. steam Basic Butler Installation, Operation & Maintenance Manual

Hide thumbs Also See for Basic Butler:

Advertisement

Quick Links

Installation, Operation & Maintenance Manual
Basic Butler / Linear
Table of Contents:
iTempo & iTempoplus Control
AromaSteam SteamHead
Linear Steam Head
MS/Super AutoFlush
Condensation Pan
mr
.
steam
PUR100474
PUR100421
PUR103936
PUR100200E
TS0012
®
Feel Good Inc.
1-15pg
16-17pg
18-28pg
29-31pg
32-33pg
Rev 5.2022

Advertisement

loading
Need help?

Need help?

Do you have a question about the Basic Butler and is the answer not in the manual?

Questions and answers

Summary of Contents for mr. steam Basic Butler

  • Page 1 Installation, Operation & Maintenance Manual Basic Butler / Linear Table of Contents: iTempo & iTempoplus Control PUR100474 1-15pg AromaSteam SteamHead PUR100421 16-17pg Linear Steam Head PUR103936 18-28pg MS/Super AutoFlush PUR100200E 29-31pg Condensation Pan TS0012 32-33pg steam ® Feel Good Inc.
  • Page 2 Installation, Operation & Maintenance Manual iTEMPO & iTEMPOPLUS ® ® CONTROLS steam ® Feel Good Inc. PUR100474 5.22...
  • Page 3: Important Safety Instructions

    When installing and using this electrical equipment, basic safety HYPERTHERMIA occurs when the precautions should always be followed, including the following: internal temperature of the body IMPORTANT SAFETY INSTRUCTIONS reaches a level several degrees above the normal body temperature of 98.6° 1.
  • Page 4: Table Of Contents

    steam ® Installation & Operating Instructions _________________________________________________________________ Table of Contents: R E A D M E F I R S T ! As you follow these instruc- Important Safety Instructions ......3 WARNING tions, you will notice warning and caution Before Installing ..........
  • Page 5: Before Installing

    steam ® Installation & Operating Instructions _________________________________________________________________ BEFORE INSTALLING Carefully inspect the control and packaging for shipping MrSteam technical service 1-800-767- 8326 for more information on the Remote Temperature damage. In the event of shipping damage, please contact Probe. the carrier for claim information. Our customer service de- partment can assist you with any missing or damaged parts.
  • Page 6: Dimensional Information

    steam ® Installation & Operating Instructions _________________________________________________________________ Dimensional Information for the Round and Square iTempo ® and iTempoPlus ® 1” ” ” 2 ” 5” ” Box Contents: 5” ” ” 12” long pigtail Drawings for Illustrative Purposes Only.
  • Page 7: Installations

    steam ® Installation & Operating Instructions _________________________________________________________________ Installation Instructions for Round & Square iTempo and iTempoPlus ® ® If the desired location for the control is outside IMPORTANT NOTE: the steam room a Remote Temperature Probe (MSTS) must be installed inside the steam room.
  • Page 8 steam ® Installation & Operating Instructions _________________________________________________________________ STEP 2 Diagram 1 Make a 2- 5 ⁄8” wide by 3- 7 ⁄8” high cutout in the desired control location. Do not oversize or under size the cutout. STEP 3 Diagram 2 Route the control cable (provided with the DIAGRAM 2 control) from the wall cutout to the steam...
  • Page 9 steam ® Installation & Operating Instructions _________________________________________________________________ STEP 5 Diagram 4 Remove and discard peel-off paper to expose adhesive liner. DIAGRAM 5 STEP 6 Diagram 5 Run a bead of silicone (provided) as shown to the outer edge of the control faceplate, following the contour of the circle or square shape.
  • Page 10: Itempo Operating Instructions

    steam ® Installation & Operating Instructions _________________________________________________________________ iTempo ® Operating Instructions The iTempo Control features programmable digital temperature control, a fixed (60) minute set at a temperature range from 80˚ up to 120˚ Set the steam bathing temperature WARNING according to personal preference, however it is highly recommended to begin steam bathing at a low temperature setting for a very short duration to gauge comfort and safety levels.
  • Page 11 steam ® Installation & Operating Instructions _________________________________________________________________ TIMER FEATURE When the control is turned ON a 60 minute time duration is initiated. The control will turn off after 60 minutes unless the control is turned off manually. MEMORY FEATURE If the control is turned off manually before 60 minutes then the default temperature of 110˚F will be used the next time the control is turned on.
  • Page 12: Itempoplus Operating Instructions

    steam ® Installation & Operating Instructions _________________________________________________________________ iTempoPlus ® Operating Instructions The iTempoPlus Control features programmable temperature control, programmable time duration, ® clock, AromaSteam, ChromaSteam mr.steam two personal settings. Set the steam bathing temperature WARNING temp time according to personal preference, however it is highly recommended to begin steam bathing at a low temperature setting for a very short duration to gauge aroma chroma...
  • Page 13 steam ® Installation & Operating Instructions _________________________________________________________________ SETTING THE CLOCK Diagram 3 When the display is not flashing: Press and hold the mr.steam TIME key until the display starts flashing. temp DIAGRAM 3 Press the TIME key to save changes. aroma SETTING THE STEAMBATH DURATION Diagram 4...
  • Page 14 steam ® Installation & Operating Instructions _________________________________________________________________ SETTING THE TEMPERATURE Diagram 6: Press TEMP key to set the desired temperature or display the temperature setting. mr.steam Diagram 7: The control is preset and will display a tempera- ture setting of 110˚F (default setting). With the temperature DIAGRAM 6 time displayed, press the UP or DOWN keys to set the desired tem-...
  • Page 15 steam ® Installation & Operating Instructions _________________________________________________________________ CHANGING THE TEMPERATURE UNITS aroma key for 10 seconds. The temperature units will be mr.steam displayed as Fahrenheit (TuF) or Celsius (TuC). Use temp time and exit. AROMASTEAM Diagram 9 chroma The AromaSteam is an optional accessory that automatically injects aromatic oil into the steam.
  • Page 16: Care And Maintenance

    steam ® Installation & Operating Instructions _________________________________________________________________ Display mr.steam Up Key Time Display/ Time Display/ temp time Adjust Key Adjust Key Down Key ON/OFF Key Program Key aroma chroma AromaSteam ChromaSteam Care Tips for all Controls and Steamheads 1. Use only mild soap and water on a soft cloth to clean the control and steamhead. 2.
  • Page 17 Installation, Operation & Maintenance Manual AromaSteam SteamHead steam ® Feel Good Inc. PUR100421 5.22...
  • Page 18 steam ® S T E A M H E A D ___________________________________________________________________________________________________________________________________________ I N S TA L L AT I O N I N S T R U C T I O N S 1/8" minimum clearance required when Acrylic Shield is used. See installation instructions Use Teflon ®...
  • Page 19 Installation, Operation & Maintenance Manual Linear Steam Head Residential Model: 104480 IMPORTANT: Leave this material with the homeowner. steam ® Feel Good Inc. PUR103936 5.22...
  • Page 20 Linear Steam Head ® ® Installer Section Model 104480 READ ME FIRST! This highlights information that is especially As you follow these instructions, you relevant to a problem free installation. will notice symbols. This information is important for the proper, safe and trouble free All information in these instructions is based on the latest installation of the Linear Steam Head.
  • Page 21 Linear Steam Head ® ® Installer Section Model 104480 accessories...etc.). If the installation and operation manuals are Steambath controls feature an integral or remote temperature sensor that senses room temperature. not available go to www.mrsteam.com for an online copy, or contact MrSteam Customer or Technical Services at 800-767- Install the linear steam head in a location where steam 8326 or 800-727-8326 for free copies.
  • Page 22 Linear Steam Head ® ® Installer Section Model 104480 Bracket Adjustment Screws Adjustable Brackets P104481 - Linear Steam Head 104483 - Faceplate BOX CONTENTS: 104484 - Diverter • Linear Steam Head • AromaTray • Faceplate • Silicone Sealant 104482 - AromaTray •...
  • Page 23 Linear Steam Head ® ® Installer Section Model 104480 Steam Head Installation Linear SteamHead shown without the optional faceplate STEP 1. Confirm proper stud spacing: The studs or diverter. must have a minimum spacing of 14-1/8” and a maximum spacing 19". If the stud spacing is outside Copper Tubing the required range then shim or otherwise reposition or Brass Pipe...
  • Page 24 Linear Steam Head ® ® Installer Section Model 104480 Optional Faceplate Installation Thin Set The steam head is supplied with an optional faceplate. It is not required for the functional operation of the steam head. The faceplate is a decorative accessory and is Vapor Barrier Finished available in (8) finishes.
  • Page 25 Linear Steam Head ® ® Installer and Home Owner Section Model 104480 Steam Emission Zone The Steam Emission Zone is the area in front of the steam head that contains dense, hot steam as it exits the steam head. Steam dissipates as it moves away from the steam head, and becomes less hot. The steam zone is the area where contact with steam presentees a scalding hazard.
  • Page 26 Linear Steam Head ® ® Installer and Home Owner Section Model 104480 Diverter The Linear SteamHead is supplied with an optional steam diverter. The steam diverter is used to reduce the steam emission zone as required to avoid contact between a steam bather and direct steam emissions.
  • Page 27 Linear Steam Head ® ® Installer and Home Owner Section Model 104480 AromaTray The AromaTray is for use with MrSteam Essential Oils. Place a few drops of Rubber Portion for secure placement Essential Oils in the AromaTray as shown to provide a fragrant steam bath experience.
  • Page 28 Linear Steam Head ® Linear Steam Head ® ® ® Using MrSteam Essential Oils Model 104480 Using MrSteam Essential Oils Model 104480 Enjoy Mr.Steam essential oils by placing a drop or two, into your Mr.Steam AromaTray as shown in the illustration. Only use Enjoy Mr.Steam essential oils by placing a drop or two, into your Mr.Steam AromaTray as shown in the illustration.
  • Page 29 Linear Steam Head ® ® Model 104480 steam ® 104482 - AromaTray 104483 - Faceplate Feel Good Inc. P104481 - Linear Steam Head, ® 104484 - Diverter SteamHead only Replacement Parts Optional Accessories Part Number Description Part Number Description 104482BB AromaTray for LSH, Brush Bronze 104485BB LSH Escutcheon Brush Bronze...
  • Page 30 Installation, Operation & Maintenance Manual S Su e Auto u ® steam ® Feel Good Inc. PUR100200E 5.22...
  • Page 31 mr . steam ® ® Optional AutoFlush System ____________________________________________________________________________________________________________________________________________ INSTA LLATION INSTRUCTIONS BOX CONTENTS: • AutoFlush System Valve with Cord • Installation Instructions. ® ASSEMBLY OF OPTIONAL AUTOFLUSH SYSTEM 3 Pin Connector for AutoFlush AutoFlush Cord Connector AutoFlush Cord Steam Generator AutoFlush Valve End "B"...
  • Page 32 AutoFlush Shown Fully Assembled INSTALLATION INSTRUCTIONS ® 1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable National and Local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush assembly must be available.
  • Page 33 Installation, Operation & Maintenance Manual Condensation Pan steam ® Feel Good Inc. TS0012 5.22...
  • Page 34 steam ® Technical Specifications Condensation Pan 103867 & 104402 Mr.Steam strongly recommends the use of a condensation pan in the unlikely event of a plumbing leak. Locate the condensation pan on a solid level surface and place the steam generator inside the condensation pan. Insure the steam generator is level.
  • Page 35 steam ® Feel Good Inc. ® www.mrsteam.com Products, information and specifications are subject to change without notice. For more information call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. steam ® I hello@mrsteam.com I www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 I 9410 S.