  • Page 1 Series 300 Electric Towel Warmers Installation, Operation & Maintenance Instructions _________________________ Model # _________________________ Serial # PUR 100559A Rev. 2/12...
  • Page 2: Table Of Contents

    Sussman-Automatic ©2011 Sussman-Automatic Corporation 43-20 34th Street 9410 S. La Cienega Blvd. ® MR. STEAM and des., A Lifetime of Pleasure, AromaFlo, AutoFlush, Clean Steam...Every Time, ChromaSteam, Club Corporation Long Island City, 11101 Inglewood CA 90301 Therapy, eTempo, eTempo/Plus, From Bathroom to Spa, Making Wellness a Way of Life, Music Therapy, Steam on info@mrsteam.com...
  • Page 3: General Information

    steam towelwarmers ® Installation, Operation & Maintenance Instructions _________________________________________________________________ HOMEOWNER: INSTALLER: ___________________________________________________ _______________________________________________ READ THIS ENTIRE INSTRUCTION MANUAL THOROUGHLY BEFORE THANK YOU for selecting Mr.Steam Towel Warmer, the perfect BEGINNING INSTALLATION. LEAVE THESE INSTRUCTIONS WITH addition to bathrooms, family spas, and exercise rooms within HOMEOWNER.
  • Page 4: Wall Preparation

    steam towelwarmers ® Installation, Operation & Maintenance Instructions _________________________________________________________________ WALL PREPARATION C A U T I O N • DO NOT mount the Towel Warmer without providing structurally secure upper and lower headers as shown. • DO NOT mount the Towel Warmer directly to sheet Finished wall surface rock or any other non-structural surface.
  • Page 5: Installation: W328, W336, W348

    steam towelwarmers ® Installation, Operation & Maintenance Instructions _________________________________________________________________ INSTALLATION: W328, W336, W348 WA R N I N G BOX CONTENTS: TO PREVENT SHOCK HAZARD, THE ELECTRICITY MUST BE • (4) Mounting bolts • Towel Warmer TURNED OFF AT THE MAIN PANEL BEFORE ANY WIRING IS DONE. •...
  • Page 6: Electrical Connections

    steam towelwarmers ® Installation, Operation & Maintenance Instructions _______________________________________________________________ ELECTRICAL CONNECTIONS 1. Assemble the BX cable BX Cable* (or greenfield) connector to the wiring box escutcheon as shown. WA R N I N G TO PREVENT SHOCK HAZARD, THE Wiring Box Escutcheon ELECTRICITY MUST BE TURNED OFF AT THE MAIN NOTE: NM (non-metallic) cable,...
  • Page 7: Optional Programmable Timer

    ® Installation, Operation & Maintenance Instructions _________________________________________________________________ GENERAL: Field Installed Wall Switch or Mr. Steam Digital Programmable Timer The Towel Warmer requires 120 VAC, 50/60 PN: 103588DIG Hz power. Specific amperage needed is listed in the Towel Warmer Specifications Chart on page 3 of this manual.
  • Page 8: Installation: Cord Models

    steam towelwarmers ® Installation, Operation & Maintenance Instructions _________________________________________________________________ INSTALLATION: W328CORD, Level Mounting Mounting Bracket not supplied Screw Indicator W336CORD, W348CORD Light Mounting Bolt Sleeve BOX CONTENTS: Extension • (4) Sleeves • Towel Warmer Mounting • (4) Mounting screws • (4) Extensions Bracket Set Screw •...