mr. steam AirButler Installation, Operation And Maintenance Manual

Advertisement

Quick Links

AirButler/AirButler2/
AirTemp Wireless Control
AromaSteam SteamHead
SteaLinx Mobile App
MS / Super AutoFlush
MX Autoflush
Condensation Pan
AirButlerX
PUR100503
PUR100421
PUR100518
PUR100200E
PUR100532
TS0012
10-16
10-15
01-18
10-15
02-19
02-19
2019-03-14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AirButler and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for mr. steam AirButler

  • Page 1 AirButler/AirButler2/ AirButlerX AirTemp Wireless Control PUR100503 10-16 AromaSteam SteamHead PUR100421 10-15 SteaLinx Mobile App PUR100518 01-18 MS / Super AutoFlush PUR100200E 10-15 MX Autoflush PUR100532 02-19 Condensation Pan TS0012 02-19 2019-03-14...
  • Page 2 steam ® Installation, Operating & Maintenance Instructions ________________________________________________________________________________________________ A i r Te m p o ® Wireless Touch Control with Steamhead Installation, Operation & Maintenance Manual ®...
  • Page 3: Important Safety Instructions

    steam ® Installation, Operating & Maintenance Instructions ________________________________________________________________________________________________ When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS thermia). Limit your use of steam to 10-15 HypertHermia occurs when the internal minutes until you are certain of your body’s...
  • Page 4: Table Of Contents

    steam ® Installation, Operating & Maintenance Instructions ________________________________________________________________________________________________ table of Contents: reaD me FirSt! Important Safety Instructions ........2 As you follow these instructions, you will notice warning and WarNiNG Before Installing ............4 caution symbols. This blocked information is important for the safe and ef- Dimensional Information .........5 ficient installation and operation of the steambath system.
  • Page 5: Before Installing

    steam ® Installation Instructions ________________________________________________________________________________________________ Before installing room a Remote Temperature Probe (PN MSTS) must be installed inside the steam Carefully inspect the control and packaging for shipping damage. In the event of room per instructions for the Remote Temperature Probe. Failure to install according to shipping damage, please contact the carrier for claim information.
  • Page 6: Dimensional Information

    steam ® Installation Instructions ________________________________________________________________________________________________ Dimensional information for the airtempo 1-5/8” 7/8” BOx CONteNtS: • AirTempo Control • Decorative Trim 3/4” 3-5/8” • Cable (3 ft.) • Wireless Receiver 4-7/8” • Batteries (2) • Mounting Screws (2) • Steamhead 3-5/8” •...
  • Page 7: Installation

    steam ® Installation Instructions ________________________________________________________________________________________________ installation instructions for airtempo Step 2 Step 1 Determine the desired installation location of the control. The AirTempo controls The AirTempo control can be surface or flush are designed to be installed inside or outside the steam room as a matter of mounted according to personal preference.
  • Page 8: Wireless Receiver

    steam ® Installation Instructions ________________________________________________________________________________________________ mounting on Glass When installing AirTempo on glass a peel and stick film is provided on pages 20-21 and may be used as a mask for a clean look from behind the glass. Wireless receiver installation Steam The control can be located up to 60 feet from the Generator...
  • Page 9 steam ® Installation Instructions ________________________________________________________________________________________________ impOrtaNt NOte: Do not rest the dongle on the steam generator, the metal case of the generator may shield the RF signal. The control features an integral temperature sensor. AirTempo Control Locate the control in a location representative of the Surface or Flush Mount desired steam bathing temperatures.
  • Page 10: Remote Temperature Probe

    steam ® Installation, Operating & Maintenance Instructions ________________________________________________________________________________________________ installing the remote temperature probe (PN: MSTS) Locating the MSTS near the steamhead or near direct steam The Remote Temperature Probe is required when the CaUtiON emissions may result in poor steam room temperature control. AirTempo control is installed outside the steam room.
  • Page 11 steam ® Installation Instructions ________________________________________________________________________________________________ DiaGram 1 Temperature Probe Connection Knock-Out Temperature Probe Cable Temperature (30 feet) Sensor Probe Mr.Steam Steam Generator (shown with cover removed and NOT installed) Drawings for Illustrative Purposes Only.
  • Page 12 steam ® Installation Instructions ________________________________________________________________________________________________ Insure a minimum of 1/4” of the temperature probe is exposed 5. Route the end of the probe cable with the temperature probe WarNiNG to the air. Failure to do so may interfere with the ability to sense tempera- through the wall into the steam room as shown in Diagram 2.
  • Page 13: Airtempo Operating Instructions

    steam ® Installation Instructions ________________________________________________________________________________________________ airtempo Operating instructions Diagram 1 ON/OFF Diagram 1 The AirTempo features programmable temperature control, programmable time duration, AromaSteam Press the ON/OFF key for 1 second to start the ON/OFF, ChromaSteam control and two personal flow of steam. The Temperature Set Point is ®...
  • Page 14 steam ® Operating Instructions ________________________________________________________________________________________________ Diagram 3 SettiNG tHe temperatUre Diagram 3: Press TEMP key to set the desired temperature or display the temperature setting. The control is preset and will display a temperature setting of 110˚F (default setting). With the temperature displayed, press the LEFT or RIGHT arrows to set the desired temperature (80°F to 120°F) in one degree increments.
  • Page 15 steam ® Operating Instructions ________________________________________________________________________________________________ arOmaSteam CHaNGiNG tHe temperatUre UNitS (˚F/˚C) When the generator is ON, press and hold the TEMP key for 10 The AromaSteam is an optional accessory that automatically seconds. The temperature units will toggle to Fahrenheit (F) or injects aromatic oil into the steam.
  • Page 16: Battery Replacement

    steam ® Operating Instructions ________________________________________________________________________________________________ Battery replacement The batteries in AirTempo will need periodic replacement. Both batteries should be replaced at the same time with new CR2450 coin cell batteries. Batteries CHOKE HAZARD. The batteries and battery doors are WarNiNG small pieces, keep out of reach of children.
  • Page 17: System Status Codes

    steam ® Maintenance Instructions ________________________________________________________________________________________________ System Status Codes Care tips for airtempo Controls and Steamheads The AirTempo may display a status code if the steam system is not 1. Use only mild soap and water on a soft cloth to clean functioning correctly.
  • Page 18: Conformity & Compliances

    steam ® Maintenance Instructions ________________________________________________________________________________________________ Ce COmpliaNCe iNFOrmatiON FOr tHe eUrOpeaN UNiON (For European Version) DeClaratiON OF CONFOrmity INSTRUCTIONS FOR DISPOSAL OF WASTE EQUIPMENT Product: MrSteam AirTempo Control BY PRIVATE USERS IN THE EUROPEAN UNION: Item Number: AirTempo This symbol on the product or its packaging indicates this product Equipment Class: III must not be disposed of with other household waste.
  • Page 19: Fcc Statements

    steam ® Maintenance Instructions ________________________________________________________________________________________________ (For North American Version) FCC/industry Canada two part Statement: NOte: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits This device complies with FCC Part 15 and Industry Canada license exempt RSS standard(s).
  • Page 20: Parts List & Technical Specs

    steam ® Maintenance Instructions ________________________________________________________________________________________________ parts list: technical Specifications: item # Description Used on Wireless receiver Unit 104208BK Electronic Assembly Black Temperature operating -20 C ~ +50 C Temperature storage -40 C ~ +85 C 104208WH Electronic Assembly White All Humidity 90%RH non-condensing 104209...
  • Page 21: Glass Mount Mask

    steam ® Installation Instructions ________________________________________________________________________________________________ Flush mount airtempo impOrtaNt NOte: Flush mount components are sold separately (104232RD & 104232SQ). Contact a MrSteam representative if a flush mount kit is needed. • Remove the surface mount bayonet from the back of the AirTempo control. The surface mount bayonet is not used when flush mounting.
  • Page 22 www.mrsteam.com Products, information and specifications are subject to change without notice. For more information call Sales & Support at: 1.800.76.STEAM 1.800.72.STEAM (East Coast) (West Coast) mr.steam Sussman-Automatic Corporation hello@mrsteam.com www.mrsteam.com ® 43-20 34th Street, Long island City NY 11101 9410 S. La Cienega Blvd., Inglewood CA 90301 800 767 8326 : 718 472 3256 800 727 8326...
  • Page 23: Flush Mount Installation

    steam ® S T E A M H E A D ___________________________________________________________________________________________________________________________________________ I N S TA L L AT I O N I N S T R U C T I O N S 1/8" minimum clearance required when Acrylic Shield is used. See installation instructions IMPORTANT: See the Installation and Operation Manual Use Teflon...
  • Page 24: Flush Mount Template

    I N S TA L L AT I O N I N S T R U C T I O N S Package Contents: SteamLinx Module and Mobile App allows for seamless • SteamLinx A with Integral Cable control of time and temperature using your smart phone •...
  • Page 25 Connecting SteamLinx B to the Home Router Home Router • Plug the blue ethernet cable provided, into an ethernet slot on the back of the home router. Power • Plug the power Supply supply into a 120V outlet. 3’ Cable Ethernet Cable (3’) Connecting SteamLinx to the Internet...
  • Page 26 mr . steam ® Optional AutoFlush ® System ____________________________________________________________________________________________________________________________________________ INSTA LLAT ION INS TRUCTI ONS BOX CONTENTS: • AutoFlush System Valve with Cord • Installation Instructions. ® ASSEMBLY OF OPTIONAL AUTOFLUSH SYSTEM 3 Pin Connector for AutoFlush AutoFlush Cord Connector AutoFlush Cord Steam Generator AutoFlush Valve...
  • Page 27 AutoFlush Shown Fully Assembled INSTALLATION INSTRUCTIONS ® 1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable national and local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush assembly must be available.
  • Page 28 steam ® Technical Specifications Condensation Pan 103867 & 104402 Mr.Steam strongly recommends the use of a condensation pan in the unlikely event of a plumbing leak. Locate the condensation pan on a solid level surface and place the steam generator inside the condensation pan. Insure the steam generator is level.

Table of Contents