EC DECLARATION OF CONFORMITY FOR MACHINES
Manufacturer:
FAAC S.p.A.
Address:
Via Benini, 1 - 40069 Zola Predosa BOLOGNA - ITALY
Declares that:
DOMOSWING mod. operator
• is built to be integrated into a machine or to be assembled with other machinery to create a machine under the
provisions of Directive 98/37/EC;
• conforms to the essential safety requirements of the following EEC directives:
73/23/EEC and subsequent amendment 93/68/EEC.
89/336/EEC and subsequent amendment 92/31/EEC and 93/68/EEC
and also declares that it is prohibited to put into service the machinery until the machine in which it will be
integrated or of which it will become a component has been identified and declared as conforming to the
conditions of Directive 98/37/EC.
Bologna, 01 January 2004
1) ATTENTION! To ensure the safety of people, it is important that you read
all the following instructions. Incorrect installation or incorrect use of
the product could cause serious harm to people.
2) Carefully read the instructions before beginning to install the product.
3) Do not leave packing materials (plastic, polystyrene, etc.) within reach
of children as such materials are potential sources of danger.
4) Store these instructions for future reference.
5) This product was designed and built strictly for the use indicated in this
documentation. Any other use, not expressly indicated here, could
compromise the good condition/operation of the product and/or be a
source of danger.
6) FAAC declines all liability caused by improper use or use other than that
for which the automated system was intended.
7) Do not install the equipment in an explosive atmosphere: the presence
of inflammable gas or fumes is a serious danger to safety.
8) The mechanical parts must conform to the provisions of Standards EN
12604 and EN 12605.
For non-EU countries, to obtain an adequate level of safety, the Standards
mentioned above must be observed, in addition to national legal
regulations.
9) FAAC is not responsible for failure to observe Good Technique in the
construction of the closing elements to be motorised, or for any
deformation that may occur during use.
10) The installation must conform to Standards EN 12453 and EN 12445.
For non-EU countries, to obtain an adequate level of safety, the Standards
mentioned above must be observed, in addition to national legal
regulations.
11) Before attempting any job on the system, cut out electrical power and
disconnect the batteries (if provided).
12) The mains power supply of the automated system must be fitted with an
all-pole switch with contact opening distance of 3mm or greater. Use
of a 6A thermal breaker with all-pole circuit break is recommended.
13) Make sure that a differential switch with threshold of 0.03 A is fitted
upstream of the system.
14) Make sure that the earthing system is perfectly constructed, and connect
metal parts of the means of the closure to it.
(DIRECTIVE 98/37/EC)
The Managing Director
A. Bassi
WARNINGS FOR THE INSTALLER
GENERAL SAFETY OBLIGATIONS
6
15) The automated system is supplied with an intrinsic anti-crushing safety
device consisting of a torque control. Nevertheless, its tripping threshold
must be checked as specified in the Standards indicated at point 10.
16) The safety devices (EN 12978 standard) protect any danger areas
against mechanical movement Risks, such as crushing, dragging,
and shearing.
17) Use of at least one indicator-light (e.g. FAACLIGHT 12VDC) is
recommended for every system, as well as a warning sign adequately
secured to the frame structure, in addition to the devices mentioned
at point "16".
18) FAAC declines all liability as concerns safety and efficient operation
of the automated system, if system components not produced by
FAAC are used.
19) For maintenance, strictly use original parts by FAAC.
20) Do not in any way modify the components of the automated system.
21) The installer shall supply all information concerning manual operation
of the system in case of an emergency, and shall hand over to the
user the warnings handbook supplied with the product.
22) Do not allow children or adults to stay near the product while it is
operating.
23) Keep remote controls or other pulse generators away from children,
to prevent the automated system from being activated involuntarily.
24)
Transit is permitted only when the automated system is idle.
25) The user must not attempt any kind of repair or direct action whatever
and contact qualified personnel only.
26) Do not short-circuit the poles of the batteries and do not try to recharge
the batteries with power supply units other than those provided with the
equipment (in the battery—powered version).
27) Do not throw exhausted batteries into containers for other waste but
dispose of them in the appropriate containers to enable them to be
recycled. Disposal costs have already been paid for by the
manufacturer (in the battery—powered version).
28) Maintenance: check at least every 6 months the efficiency of the
system, particularly the efficiency of the safety devices (including,
where foreseen, the operator thrust force) and of the release devices.
29) Anything not expressly specified in these instructions is not permitted.

Advertisement

loading

Summary of Contents for FAAC DOMOSWING battery

  • Page 1 FAAC are used. 6) FAAC declines all liability caused by improper use or use other than that for which the automated system was intended. 19) For maintenance, strictly use original parts by FAAC.
  • Page 2: Technical Specifications

    Front fitting Release Bracket bush Fig. 1 Fig. 2 TECHNICAL SPECIFICATIONS Tab. 1 - Technical specifications of DOMOSWING operator MODEL DOMOSWING battery DOMOSWING transformer Power supply 12Vdc Rated absorbed power (W) Max static force (N) 1000 Load-free linear speed (cm./sec.)
  • Page 3: Installation

    4.2. Installation dimensions INSTALLATION 4.1. Preliminary checks There are 4 possible installation dimensions Z as shown in Fig. 3. To ensure safety and an efficiently operating automated system, make sure the following conditions are observed: •The enclosures of the control boards (see relevant instructions) should be installed at a distance from the 1 st hole operators not requi ring the motor cable to be extended.
  • Page 4 4.3. Installation sequence 4.3.1 Installing the rear fitting 4.3.4 Inserting the bush - front fitting Secure the rear fitting to the pillar by welding or using suitable Insert the bush (Fig. 7 Ref. ) in the front fitting (Fig. 7 Ref. expansion plugs (Fig.
  • Page 5: Manual Operation

    4.3.7 Installing the front fitting MANUAL OPERATION • Turn the release key anti-clockwise for 2-3 turns. If the gate has to be moved manually due to a malfunction of the automated system, use the release device as follows: • Remove the fitting from the operator and fit it on the leaf. The fitting can be either welded directly or screwed on, using the •...
  • Page 6 DESCRIPTION These instructions apply to the following models: FAAC DOMOSWING The FAAC DOMOSWING automated system for residential swing gates consists of non-reversing electro-mechanical linear operators, powered by 12 Vdc, through battery or transformer. Each operator is coupled to an electronic...

This manual is also suitable for:

Domoswing transformer