Advertisement

Quick Links

940SMT
940SMT

Advertisement

Table of Contents
loading

Summary of Contents for FAAC 940SMT

  • Page 1 940SMT 940SMT...
  • Page 2: Warnings For The Installer

    21) Do not allow children or other persons to stand near the product while in 6) FAAC accepts no responsibility due to improper use of the automated operation. system or use other than that intended.
  • Page 3 ENGLISH ENGLISH KEY TO PROFILES SUPPORT PROFILE FREE-STANDING PROFILE TELESCOPIC PROFILE HOUSING PROFILE SLIDING PROFILE CLOSING PROFILE FOR STANDARD AUTOMATED SYSTEM CLOSING PROFILE FOR FREE-STANDING AUTOMATED SYSTEM CLOSING PROFILE FOR TELESCOPIC AUTOMATED SYSTEM LEAF ATTACHMENT PROFILE LEAF BOTTOM PROFILE GRIPPER FOR GLASS LEAVES BOTTOM SLIDING BLOCK FOR GLASS LEAF...
  • Page 4 ENGLISH ENGLISH Fig. 1...
  • Page 5 ENGLISH ENGLISH 71,5 179,5 15 15 21,4 Fig. 2...
  • Page 6 ENGLISH ENGLISH 71,5 35,5 71,5 15 15 49,6 76,2 37,7 Fig. 3...
  • Page 7: Description And Technical Specifications

    T21IF). The motor lock unit acts directly on the motor by locking it DESCRIPTION AND TECHNICAL SPECIFICATIONS mechanically. With the FAAC series 940 SMT systems, two- or four-leaf sliding doors Motor lock control can be automatically activated, managed and controlled.
  • Page 8 ENGLISH ENGLISH 940 SMT2/SMTA2 Right opening Lt = Vp x 1,5 + 100 SM control board unit SMT transmission unit Buffer batteries unit Motor/transformer unit Fig. 4 Vp = Free transit space Lt = Head profile length 1100 1750 1280 2705 2845 B = Securing distance of front carriages on sliding leaf.
  • Page 9 ENGLISH ENGLISH 940 SMT2/SMTA2 Left opening Lt = Vp x 1,5 + 100 SM Control board unit SMT transmission unit Motor/transformer unit Buffer batteries unit Fig. 5 Vp = Free transit space Lt = Head profile length 1100 1750 1280 2705 2565 B = Securing distance of front carriages on sliding leaf.
  • Page 10 ENGLISH ENGLISH 940 SMT4/SMTA4 Double-leaf Lt = Vp x 1,5 + 100 Buffer batteries unit SMT transmission unit SM Control board unit Motor/transformer unit Fig. 6 Vp = Free transit space Lt = Head profile length 1400 2200 1025 3745 3885 B = Securing distance of front carriages on sliding leaf.
  • Page 11: Installation

    ENGLISH ENGLISH INSTALLATION HA = (LH-15,4 mm) ± 10 Fig. 7...
  • Page 12 ENGLISH ENGLISH HA = (LH-15,4 mm) ± 10 Fig. 8...
  • Page 13 ENGLISH ENGLISH SECURING THE HEAD PROFILE There are two types of head profiles: •SUPPORTING: This profile is used when the head profile can be completely secured to a bearing structure in metal or masonry without any significant deformation. •FREE-STANDING: This is the aluminium profile which, when assembled on the telescopic support profile, provides the free-standing characteristic to the head profile.
  • Page 14 ENGLISH ENGLISH •Loosen the three screws as shown in fig. 19 ref. and adjust INSTALLATION OF BOTTOM SLIDING BLOCKS the leaf. The bottom sliding blocks are designed for securing to the wall •Loosen the two screws as shown in fig. 20 ref. (without (or stationary leaf) or to the floor.
  • Page 15 ENGLISH ENGLISH In case of single leaf with left opening adjust the lower belt •Loosen the fixing screws (fig. 23 ref. ) of the carriage in tension as follows: question. Take the carriage toward the limit stop until the two •Loosen the nut (fig.
  • Page 16: Motor Lock

    ENGLISH ENGLISH MOTOR LOCK 12.1 Installation of internal release knob The motor lock is a device guaranteeing the leaves are •Assemble the release knob as indicated in fig. 32 ref. locked when closed.Installation procedure: •Press the contrast washer until it fits in the release knob. •Secure the motor lock with the two supplied bolts as shown •Screw the adjuster, with the relevant lock nuts, on the in fig.
  • Page 17 ENGLISH ENGLISH FITTING THE HOUSING •Fit three spacers (fig. 34 ref. )on the outer edge of the support profile, positioning them at the ends and at the centre. Fig. 34 •Lay the housing on the spacers. •To keep the housing open, lift it and push it toward the profile until the metal projection fits into the profile seat (fig.35 ref.
  • Page 18 ENGLISH ENGLISH INSTALLATION WITH GRIPPERS FOR GLASS LEAVES To install with the glass leaves grippers, refer to the dimensions in figure. 40. HA = LH - (4,5 + 18,4) + 21 ± 10mm Fig. 40...
  • Page 19 ENGLISH ENGLISH START-UP •To remove the protective cover of the SDM control unit, delicately obtain leverage with a screwdriver as shown in fig. •To refit it, attach it on the top part and press as shown in fig. •To remove the motor unit's cover, loosen the screws. •Manually check correct movement of the leaves and all moving elements.
  • Page 20 ENGLISH ENGLISH 940SDM CONTROL BOARD 940SDM CONTROL BOARD 940SDM CONTROL BOARD 940SDM CONTROL BOARD 940SDM CONTROL BOARD MAIN V ACC V MOT + 24V OUT 3 OUT 2 OUT 1 E-DET I-DET PSW 1 PSW 2 EM.1 EM.2 OPENED NIGHT 2 3 4 5 6 7 8 9 10 11 12 13...
  • Page 21 ENGLISH ENGLISH TERMINAL BOARD J6 TERMINAL BOARD J5 SD-KEEPER EXTERNAL SENSOR NO NC 2x0.5mm max 50m + SD-KEEPER E-DET - SD-KEEPER I -DET $ $ $ $ $ OUT 1 PSW 1 NO NC $ $ $ $ $ LOCK PSW 2 $ $ $ $ $ OPENED...
  • Page 22: Description Of Terminals

    ENGLISH ENGLISH DESCRIPTION OF TERMINALS DESCRIPTION OF TERMINALS DESCRIPTION OF TERMINALS DESCRIPTION OF TERMINALS DESCRIPTION OF TERMINALS J6 TERMINAL BOARD J6 TERMINAL BOARD J6 TERMINAL BOARD J6 TERMINAL BOARD J6 TERMINAL BOARD +24V TERMINAL BOARD J5 TERMINAL BOARD J5 TERMINAL BOARD J5 TERMINAL BOARD J5 TERMINAL BOARD J5 +24V power supply for accessories.
  • Page 23 ENGLISH ENGLISH ST ST START ART-UP the jumper (see the SD-Keeper programming instructions). The first time the door is powered, the 940SDM control -2 PHOTOCELLS board automatically executes a setup procedure and •connect the photocells to the PSW1 and PSW2 inputs. loads all the standard configuration settings.
  • Page 24: Speed Changes

    ENGLISH ENGLISH SPEED CHANGES SPEED CHANGES SPEED CHANGES SPEED CHANGES SPEED CHANGES The reset procedure is necessary following the occurrence of certain conditions causing the door to stop There are 10 speed adjustment levels for opening and operating: closing. •after an obstacle is detected on 3 successive occasions Level 10 refers to the maximum speed permitted by door during closing/opening when the function STANDARD weight, whereas level 1 refers to the corresponding...
  • Page 25 ENGLISH ENGLISH SD-KEEPER PROGRAMMING UNIT SD-KEEPER PROGRAMMING UNIT SD-KEEPER PROGRAMMING UNIT SD-KEEPER PROGRAMMING UNIT SD-KEEPER PROGRAMMING UNIT SD-Keeper is used for selecting operational functions, as SD-Keeper can be disabled by a combination of keys (see well as adjusting and programming the 940 SF series the special LOCK function) or by internally fitting a jumper automated doors.
  • Page 26 ENGLISH ENGLISH ³ MANUAL TWO-WAY · ONE WAY PARTIAL OPENING » TOTAL OPENING AUTOMATIC ¿ ³ ´ · » ¿ DOOR OPEN ´ NIGHT fig. 4 OPERA OPERA TING FUNCTIONS TING FUNCTIONS SPECIAL FUNCTIONS SPECIAL FUNCTIONS OPERA OPERATING FUNCTIONS OPERA TING FUNCTIONS TING FUNCTIONS SPECIAL FUNCTIONS...
  • Page 27 ENGLISH ENGLISH FL FL FL FL FLOW OW-CHART SD -CHART SD -CHART SD-KEEPER -CHART SD -KEEPER -KEEPER -KEEPER -CHART SD -KEEPER To access programming while the standard view is shown Time on the display, press any of keys Date Programming is subdivided into main menus (see box) split into subjects.
  • Page 28 ENGLISH ENGLISH FL FL FL FL FLOW OW-CHART SD -CHART SD -CHART SD -CHART SD-KEEPER -KEEPER -KEEPER -KEEPER -CHART SD -KEEPER BATTERY BATTERY KIT BAT. OPERATION STANDARD NO STANDARD LAST OPERAT. OPENING CLOSING NIGHT BATT STANDARD NO STANDARD EXIT LOCK NIGHT LOCK ONE WAY+NIGHT...
  • Page 29 ENGLISH ENGLISH FL FL FL FL FLOW OW-CHART SD -CHART SD -CHART SD-KEEPER -CHART SD -KEEPER -KEEPER -KEEPER -CHART SD -KEEPER incorrect code PASSWORD PASSWORD PASSWORD PASSWORD ADVANCED MENU 0000 0000 0000 0000 correct code OPERATION CLOSING SPEED PARAMETERS OPENING SPEED OPENING: CLOSING: DECEL.
  • Page 30 ENGLISH ENGLISH FL FL FL FL FLOW OW-CHART SD -CHART SD -CHART SD -CHART SD -CHART SD-KEEPER -KEEPER -KEEPER -KEEPER -KEEPER incorrect code PASSWORD PASSWORD PASSWORD PASSWORD ADVANCED MENU 0000 0000 0000 0000 correct code OPERATION PARAMETERS SPEED: IN/OUT SETUP EMERG 1 OPEN STANDARD...
  • Page 31 ENGLISH ENGLISH FL FL FL FL FLOW OW-CHART SD -CHART SD -CHART SD-KEEPER -CHART SD -KEEPER -KEEPER -KEEPER -CHART SD -KEEPER incorrect code PASSWORD PASSWORD PASSWORD PASSWORD ADVANCED MENU 0000 0000 0000 0000 correct code OPERATION PARAMETERS IN/OUT SETUP restores STAND SETUP VARIOUS STANDARD...
  • Page 32 ENGLISH ENGLISH FL FL FL FL FLOW OW-CHART SD -CHART SD -CHART SD-KEEPER -CHART SD -KEEPER -KEEPER -KEEPER -CHART SD -KEEPER SUN 00:00 SUN 00:00 SUN 00:00 SUN 00:00 DOM 00:00 CLOCK 00/00/00 00/00/00 00/00/00 00/00/00 00/00/00 SUN 00:00 SUN 00:00 SUN 00:00 SUN 00:00 DOM 00:00...
  • Page 33 ENGLISH ENGLISH 1 1 1 1 1 LANGUAGE LANGUAGE LANGUAGE LANGUAGE LANGUAGE 3 3 3 3 3 BA BAT T T T T TERY TERY TERY TERY TERY Selects the language for showing the messages on the display. 3.1 BA 3.1 BAT T T T T TERY KIT 3.1 BA TERY KIT...
  • Page 34: In/Out Setup

    ENGLISH ENGLISH 2 IN/OUT SETUP 2 IN/OUT SETUP 2 IN/OUT SETUP 2 IN/OUT SETUP 2 IN/OUT SETUP 5 5 5 5 5 DIAGNOSTICS DIAGNOSTICS DIAGNOSTICS DIAGNOSTICS DIAGNOSTICS Emerg 1 Emerg 1 Emerg 1 Emerg 1 Emerg 1 5.1 940SDM 5.1 940SDM 5.1 940SDM 5.1 940SDM 5.1 940SDM...
  • Page 35 ENGLISH ENGLISH 2.6 OUT 1 2.6 OUT 1 2.6 OUT 1 2.6 OUT 1 2.6 OUT 1 Standard Standard Standard Standard Standard When power is restored after a blackout, the door remains set 2.7 OUT 2 2.7 OUT 2 2.7 OUT 2 2.7 OUT 2 2.7 OUT 2 in its “manual”...
  • Page 36 ENGLISH ENGLISH L L L L L OCK SUR OCK SUR OCK SURVEILLANCE OCK SUR VEILLANCE VEILLANCE VEILLANCE OCK SUR VEILLANCE TIME BAND 3: FUN 8 7 p.m. TIME BAND 4: FUN 0 This accessory enables a check of lock efficiency and, in TIME BAND 5 : FUN 0 the event of an error, this is signalled by the SD-Keeper.
  • Page 37 ENGLISH ENGLISH BAT T T T T TERY KIT TERY KIT TERY KIT TERY KIT TERY KIT By using the SD-Keeper+Display, you can select door behaviour in battery operation mode, so that, if mains power fails: Battery card installation procedure: OPERATING FUNCT.
  • Page 38 ENGLISH ENGLISH INTERL INTERL INTERL INTERLOCK INTERL INTERLOCK WITH INTERNAL SENSORS INTERLOCK WITH INTERNAL SENSORS INTERLOCK WITH INTERNAL SENSORS INTERLOCK WITH INTERNAL SENSORS INTERLOCK WITH INTERNAL SENSORS INTERLOCK WITHOUT INTERNAL SENSORS INTERLOCK WITHOUT INTERNAL SENSORS INTERLOCK WITHOUT INTERNAL SENSORS INTERLOCK WITHOUT INTERNAL SENSORS INTERLOCK WITHOUT INTERNAL SENSORS This application is recommended when the distance This application is recommended if the doors are so near...
  • Page 39: Diagnostics Guide

    ENGLISH ENGLISH DIAGNOSTICS GUIDE DIAGNOSTICS GUIDE DIAGNOSTICS GUIDE DIAGNOSTICS GUIDE DIAGNOSTICS GUIDE The following is a list of the specified alarms plus the relevant explanation/solution. SD-Keeper+Display shows the alarm number and description on the Diagnostics menu. Only the SD-Keeper shows the type of alarm by a combination of flashing LEDs (referring to the figure on the side).
  • Page 40 ENGLISH ENGLISH Photocell 1 faulty. This signal is shown only if the FAILSAFE function is Check the following: active and at least 1 photocell was configured. •is photocell 1 aligned correctly? •photocell 1 connections •is photocell 1 in good condition and efficient? SETUP execution is impeded When the trouble fault is removed, SETUP starts Check the following:...
  • Page 41: Troubleshooting

    ENGLISH ENGLISH TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING The following will help you identify and solve some particular states. STATE SUGGESTION •no mains power supplied and the 940SDM control board is battery-powered in NIGHT operating function, SD-KEEPER off and in energy saving statues. •connection to the 940SDM control board is interrupted: check the connection cables and wiring between SD-Keeper and the 940SDM control board •940SDM control board not operating correctly;...
  • Page 42 Les descriptions et les illustrations du présent manuel sont fournies à titre indicatif. FAAC se réserve le droit d’apporter à tout moment les modifications qu’elle jugera utiles sur ce produit tout en conservant les caractéristiques essentielles, sans devoir pour autant mettre à...

This manual is also suitable for:

940smt2940smta2940smt4940smta4

Table of Contents