1. INTRODUCTION TO THE INSTRUCTIONS MANUAL This manual provides the correct procedures and requirements for installing A952 and maintaining it TABLE E.g.: 1 see Table 1. in a safe condition. § In Europe, the automation of a door falls under the Ma- CHAPTER/SECTION E.g.: §1.1 see section 1.1.
2. A952 2.1 STORAGE 2.2 UNPACKING AND HANDLING Keep the product in its original packaging, in a 1. Open and remove all packaging elements. dry place indoors, away from direct sunlight, dust 2. Check that all components are present and intact.
11/23 0051 produced in November 2023 S/N 51 Warning that the motor can become very hot DIN 18650-1 classification and component trace- Warning to unload the spring before ability disconnecting the motor label Component traceability label A952 532310 - Rev.A...
One operator must be installed on each leaf. - It is prohibited to install the A952 in marine ap- plications. - It is prohibited to use the A952 in the following...
- MANUAL mode selected - Power supply disconnected. A952 is a reversible door operator and is therefore not fitted with a release device that has to be actuated before the leaf is moved manually. If there is a lock, make sure that it has been unlocked before moving the leaf manually.
(according to the type of installation) with an adjustable speed, in the absence of power or in manual mode. The A952 can control a lock or an electromagnet to lock the door. The A952 automates a single leaf and using a canbus...
Points above the curve correspond to weight and length combinations that cannot be automated using the A952. The maximum opening angle or range of opening angles are indicated in each graph by the symbol...
1200 1300 1400 1500 1600 ■ SHOE ARM ( 0-160 max. leaf weight according to the width (max. 130 kgm2) short arm standard arm Max: 105°- 110° Max: 105° 1000 1100 1200 1300 1400 1500 1600 A952 532310 - Rev.A...
LEAF MOUNTED (*) The minimum leaf width for the A952 with a battery is 841 mm ■ ARTICULATED ARM ( max. leaf weight according to the width (max. 130 kgm2) Max: 100° 1000 1100 1200 1300 1400 1500 1600 ■ SHOE ARM ( max.
Weight = 90 kg , Length = 1.4 m Inertia = (90 x 1.4 ) / 3 = 59 kg Maximum speed level that can be set = 7 Max. speed level Inertia 100 110 120 130 140 [kgm2] A952 532310 - Rev.A...
SPIRIT LEVEL DRILL WIRE STRIPPER/CABLE LUG CRIMPER TORQUE WRENCH - if necessary for safety, a torque wrench and the TIGHTENING TORQUE will be specified. E.g.: HEX WRENCH 6 set at 2 Nm x.x Nm 2 Nm A952 532310 - Rev.A...
3.2 INSTALLATION INSTRUCTIONS PERMISSIBLE SUBSTRATES The A952 can be mounted on the following materials: concrete, concrete and masonry (comparable to concrete), solid brick (holes <15%), wood, steel SUBSTRATE CONDITION Before installation, you should carefully check the condition of the existing substrate that the system will be anchored to.
Anchoring to a masonry lintel is not allowed since the strength of the dowels are lower than those of calcu- lation; if brick platbands are present, a special counterplate should be anchored to the masonry and tested. A952 532310 - Rev.A...
A shape marked on the plate indicates the mounting position of the gearmotor, which should be secured using the 4 holes shown: The gearmotor should be mounted after the plate has been installed. A952 532310 - Rev.A...
3.4 TYPES OF INSTALLATION 1. Decide the direction in which to install of the plate, considering the position of the gearmotor accord- The A952 offers several installation options: ing to the type of application (refer to 1- 7). A. On the architrave 2.
(4). When the two inserts are inside the plate guide, not in correspondence with the insertion slots, the weight of the gearmotor is supported by the plate, making it easier to carry out the subsequent installation operations. 4 A952 532310 - Rev.A...
Page 30
3. Secure the gearmotor using the four M6x75 screws tipped with threadlocker (5), by inserting them through the spacers (6) and tightening them with a torque of 9 Nm. (7). 4. Apply the self-adhesive cable clips (8). (M6x75) x4 5 9 Nm 6 7 8 A952 532310 - Rev.A...
3.6 CABLE ROUTING FROM THE BOARD SIDE battery cable accessories cable mains power supply cable accessories cable motor cable encoder cable side selector switch A952 532310 - Rev.A...
3.7 CABLE ROUTING FROM THE MOTOR SIDE accessories cable battery cable accessories cable clamps mains power supply cable clamps accessories cable mains power supply cable clamps side selector switch encoder cable motor cable A952 532310 - Rev.A...
The electronics assembly must be installed on the plate with the mains power supply terminals towards the end of the plate (9-1). 9 2. Mount the bracket as shown in 10,according to the position of the electronic assembly: 10 3. Partially tighten the M5x12 self-tapping screw (11): 11 A952 532310 - Rev.A...
Page 34
- Motor cable connector (3) Use one of the clamps supplied to gather the cables together and secure them. WARNING: For safety reasons, fully unload the spring before dis- connecting the motor cable from the board. 13 A952 532310 - Rev.A...
4. At the end, after having reached the maximum rotation, keep the arm in position, remove the cam and reinsert it, moving it back by two shaft teeth with respect to the mechanical stop, in order to leave some space (about 20°). 5. Remove the arm. 14 15 A952 532310 - Rev.A...
Page 36
4. Press the side covers onto the guide. 5. Keep the door closed and slide the shoe inside the guide until it is possible to connect the arm to the gearmotor. 10 Nm 10 Nm 16 A952 532310 - Rev.A...
Page 37
Make sure that you install the disc spring washer as shown in 18-2. 4. Press the cover on (4). 5. In the opening by spring application, remove the cam that was inserted previously (15-1). 20 Nm 18 17 20 Nm 19 A952 532310 - Rev.A...
4. At the end, after having reached the maximum rotation, keep the arm in position, remove the cam and reinsert it, moving it back by two shaft teeth with respect to the mechanical stop, in order to leave some space (about 20°). 5. Remove the arm. 20 21 A952 532310 - Rev.A...
Page 39
10 Nm 22 90° 7 Nm This figure shows one of the possible applications. In any application, the guide, with the door closed and the arm inserted, must be perpendicular to the fixing surface. 23 A952 532310 - Rev.A...
Page 40
Make sure that you install the disc spring washer as shown in 25-2. 4. Press the cover on (4). 5. In the opening by spring application, remove the cam that was inserted previously (15-1). 20 Nm 24 25 20 Nm 26 A952 532310 - Rev.A...
Before removing the arm, move the leaf slightly away from the closed position, if it is a closing spring, or from the open position, if it is an opening spring, and fully tighten the screw. Only remove the screw after the arm has been reconnected to the operator. 27 A952 532310 - Rev.A...
3.12 ADJUSTING THE SPRING The A952 is fitted with a spring that opens or closes the door (according to the application) in the absence of mains power. The spring is factory set to the minimum preload. According to the characteristics of the door (e.g. friction, seals, air currents), the preload can be adjusted to obtain the appropriate force for the movement.
The KICK LOCK function can be useful, for example, to make it easier to complete the closing stroke if the seals are hard or when the electric lock engages. The KICK LOCK function can ONLY be activated in closing spring applications. Set the selector J8 as shown in 32. A952 532310 - Rev.A...
Page 44
■ ADJUSTING THE POINT AT WHICH THE SOFT DRAW / KICK LOCK TRIGGERS The A952 is fitted with a micro switch that determines that point at which the SOFT DRAW or KICK LOCK function is activated (according to the setting of selector J8).
3.14 ADJUSTING THE INTEGRATED MECHANICAL OPENING STOP The A952 is fitted with an integrated mechanical stop that limits the opening stroke. 1. Open the door to the position at which you want the internal stop to operate. 2. Turn the screw in the cam according to the direction of rotation of the gearmotor shaft in order to reach the position, as shown in 34.
3. Press the selector into the rectangular opening so that position 1 (indicated by the line) is facing upwards. 4. Apply the sticker with the number 1 facing upwards. 5. Plug the cable into the "SEL" connector (41) 38 A952 532310 - Rev.A...
3. Connect the wires of the mains power cable (phase / neutral / earth) following the instructions on the label. 4. Secure the wires using one of the clamps provided. 5. Install the terminal board plastic cover. 40 A952 532310 - Rev.A...
- LED on: input closed towards negative - LED off: input open OUTPUTS The A952 has 5 outputs on which both the function and type of contact (NO/NC) can be programmed. +24 V The outputs are activated according to the pro-...
Lock control relay output Lock control relay output Common relay contact ACCESSORIES POWER SUPPLY The A952 supplies 24 V " and is short-circuit protected with a maximum current of 1.2 A between the +24 V e - COM terminals. 44 This dedicated connector is specifically for connecting single channel FAAC BUS 2easy control devices.
RESET has to be carried out in order for the automation to start operating normally again. EMERGENCY OPEN When the input is activated, the automation opens and remains open as long as the emergency is active. A952 532310 - Rev.A...
If the door is opening, it has no effect OPENING SAFETY Connect the opening safety devic- es. This input is activated: - If the door is opening, it stops until it is released - If the door is already closed, it prevents it from A952 532310 - Rev.A...
Page 53
Enable the TEST (FAILSAFE) on the input XPB ON, XPB SCAN, XPB SCAN 3D Adjust the parameters related to move- ment, i.e.: Encoder 1) Opening speed Opening in LOW ENERGY – Pl d 2) opening strength 3) opening strength duration A952 532310 - Rev.A...
(Safe Flow function). INTERNAL GREEN TRAFFIC LIGHT Controls the green light inside the room to regulate the flow of people to one person at a time (Safe Flow function). A952 532310 - Rev.A...
ACCESSING PROGRAMMING MODE Before starting up the system, make sure that the door Programming the A952 is divided in to two levels: moves smoothly and without friction. BASIC and ADVANCED. 1. Turn power on to the A952.
Adjustable from 0 to 30 s NIGHT PAUSE TIME Adjusts the time the door remains open after a com- mand in NIGHT mode, before automatic reclosing Adjustable from 0 to 90 s CLOSING SPEED Adjustable from 1 (minimum) to 10 (MAX) A952 532310 - Rev.A...
Defines the opening delay time of the door to allow the OUTPUT CONFIGURATION OUT 3 lock to be released, particularly the motorised ones. Adjustable from tenths of a second CONTACT TYPE - OUTPUT OUT 3 OUTPUT CONFIGURATION OUT 4 CONTACT TYPE - OUTPUT OUT 4 A952 532310 - Rev.A...
Page 58
The internal detector is disabled immediately after opening and in any case upon expiry of the set delay. Adjustable from 0 to 90 s A952 532310 - Rev.A...
4. When finished, the display switches to the auto- Default values: mation status view. 8.5 RESET A RESET consists of initialising the A952, which must be carried out while an error condition is present in order to attempt to restore normal operation.
With sufficiently dimensioned safety distances Automatic door safety - With protection to prevent fingers being crushed, shorn off or drawn in construction / installation With integrated break-out unit With safety sensors Ambient temperature Ambient temperature range specified by manufacturer 46 A952 532310 - Rev.A...
6. Fill out the EC declaration of conformity and the system register. 7. Give the EC Declaration, the system register with the maintenance plan and the instructions for use of the automation to the system owner/operator. 47 A952 532310 - Rev.A...
3. Check that the devices are working properly. 10.1 BUS 2EASY DEVICES BUS 2EASY DEVICE REGISTRATION Single channel FAAC BUS 2easy control devices can be Registration is required: connected to this board. - When the automation is first started or after the...
The battery kit can be mounted on whichever side of the A952 you prefer as long as there is enough space at the side. The functions selector can also be mounted on...
Page 64
6. Install the press-on front cover and fasten it using the 4 screws. 7. Plug the connector into the E952CL board. A952 532310 - Rev.A...
Opening safety grey violet (13) IN4 (13) IN4 Closing safety Closing safety blue blue (24) OUT2 (24) OUT2 Test Test (10 / 11) IN1 / IN2 Open only for XPB SCAN 3D 48 49 A952 532310 - Rev.A...
If the door is used as an escape route, the lock should communication with the automation. not be used. Simply Connect requires an accessory FAAC connec- tivity module. If the lock needs to be powered in order to be released, Insert the module into the dedicated plug-in con- connect it as indicated in 50.
1. Install the mounting brackets for the casing as shown in the figures above. 2. Cut the casing profile to the right length. 3. Drill holes for the fixing screws and, where necessary, the slots. 4. Install the casing and secure it using the screws provided. A952 532310 - Rev.A...
The lock device is optional. Connect a key com- ERRORS In the event of errors, the combination of mand with an NC contact to terminals G and K. LEDs corresponding to the active error flashes for a few seconds ( 4). 52 A952 532310 - Rev.A...
54 KS EVO connection Connect to the terminals as shown. Assembling the KS EVO V RX TX G KS EVO V RX TX G U/UTP CAT.5 4x2xAWG24 V RX TX G E952IO board 55 A952 532310 - Rev.A...
Note: if no buttons are pressed, after 2 minutes the display reverts to the HOME PAGE. KP EVO 1 2 3 4 5 6 KP EVO FW version VERSION x.x A952 THU 20/03/20 HOME PAGE AUTO BIDIR 14:30 56 A952...
(icon highlighted on the display) - Time and disabled. Every time it is changed, the mode that is enabled is immediately updated on the display. A952 Symbols on the HOME PAGE: current indications THU 20/03/21 ...
- ESC button to go back to the HOMEPAGE - OK button to access the function/confirm the programming and go back to the MENU MENU - > 1 LANGUAGE PROGRAMMING ERRORS WARNINGS ↑ ↑ ↓ ↓ 58 A952 532310 - Rev.A...
OK see specific diagram PROGRAMMING OK see § Diagnostics ERRORS OK see § Diagnostics WARNINGS CYCLES COUNT CYCLES NUMBER OK COUNTERS SAFE FLOW FUNCTION MAINTENANCE OK PEOPLE IN NUMBER CYCLES RESET PEOPLE IN UPDATE A952 532310 - Rev.A...
Page 76
PAUSE TIME P&G PRIMARY/SECONDARY NR. NIGHT PAUSE TIME INTERCOM REG. NIGHT SENSOR DELAY NODE LIST MISCELLANEUS DEFAULT CONFIG. OK MOTOR LOCK KIT FUNCTION OK BOARD'S DISPLAY LOCK DELAY INTRUSION RELEASE TYPE KPEVO KEY CONSECUTIVE OBST. TEST ERROR DIMMER A952 532310 - Rev.A...
Defines the opening delay time of the door to allow the lock to be DOOR STATUS released, particularly the motorised ones: 0-60 tenths of a second. The display indicates the status of the automation in real-time. A952 532310 - Rev.A...
Page 78
TEST ERROR on an input configured as SAFETY. ENABLED: movement at minimum speed DISABLED: the door will stop in an error condition DIMMER Specifies the percentage brightness of the KP EVO display in standby (10%…90%). A952 532310 - Rev.A...
The counting of entrances and exits takes place by the activation of Operating mode the internal and external buttons. The A952 can be programmed to 1 or more TIME BANDS can be programmed (max 6) in 24 h. indicate, and if necessary, close the entrance, when the set maximum When the automation exits from a programmed TIME BAND, if there number of people on the premises has been reached.
Enter the TECHNICIAN PSW or the current USER PSW , then follow the same procedure as for the TECHNICIAN PASSWORD. MENU 9 INFO Allows the firmware versions of the KP EVO, and board to be viewed. A952 532310 - Rev.A...
ADDRESSING the network. A unique ID must be assigned to each A952 in the - INTERLOCK: two single doors, where the opening network as indicated below. of one is subject to the closing of the other and Do not assign the same ID to more than one unit in vice versa.
14.1 INTERMODE 14.2 INTERLOCK 60 shows the ID to assign to the A952 units in the 61 shows the ID to assign to the A952 units in the network. network. The system consists of a PRIMARY unit and a maximum Either of the two units can be designated as the PRI- of 14 SECONDARY units.
14.3 2 LEAVES INTERLOCK WITHOUT MEMORY With 4 sensors: the second opening is not automatic. 62 shows the ID to assign to the A952 units in the In order to open the door, the internal/external sensor network. must be triggered when the other door is closed. If the...
- Save data to a USB pen drive (DOWNLOAD) Release the buttons and use the p p or q q buttons to FAAC provides updated firmware in a package called select the method for saving the file to the root of...
LED flashing quickly SETUP in progress ■ BLUE LED LED flashing normal operation LED off A952 off LED Power LED Inputs 16.2 INPUTS AND OUTPUTS STATUS CHECK The status of each input and output can be checked on the board or via the KP EVO.
ON THE BOARD Errors are malfunctions that prevent the automation The display of the A952, if you are not in programming from working. They are indicated by a steady red LED mode, displays the code that indicates the status of on the E952CL board and by automation status 13 that the automation.
187 Pa 151 Pa 115 Pa 80 Pa 2600 68 km/h 61 km/h 55 km/h 48 km/h 40 km/h 2500 2400 284 Pa 75 km/h 2300 2200 2100 2000 1000 1100 1200 1300 1400 1500 leaf width A952 532310 - Rev.A...
34 Pa 26 Pa 18 Pa 2600 32 km/h 26 km/h 23 km/h 19 km/h 2500 42 Pa 29 km/h 2400 64 Pa 36 km/h 2300 2200 2100 2000 1000 1100 1200 1300 1400 1500 leaf width A952 532310 - Rev.A...
The TIMER is enabled on the board. TIMER function in progress A TIMER mode function is in progress. Obstacle detected when closing The notification disappears on the next movement. Obstacle detected when opening The notification disappears on the next movement. A952 532310 - Rev.A...
Page 90
Error on one or more canbus nodes. Non-standard programming The board appears to be programmed with values that are not the default settings Incorrect PRIMARY/SECONDARY configuration Check settings Control board data deletion All the data has been deleted from the E952CL board. A952 532310 - Rev.A...
Low traffic Medium traffic High traffic 15 A952 maintenance (up to 10 cycles/h) (10-100 cycles/h) (over 100 cycles/h) Check that the cover/casing and all the movable guards are integral and that they are fastened correctly.
Page 92
Check that the CE marking and the DANGER AUTOMATIC MOVEMENT 24 months 12 months 6 months warning sign on the door are present, intact and legible A952 532310 - Rev.A...