Page 3
TÜV Italia S.r.l. - TÜV SÜD Group via G. Carducci, 125 pal 23 20099 Sesto S. Giovanni (MI)- Italy T. +39 02 24130 1 F. +39 02 24130 0399 Web: www.tuv.it – @-mail: tuv.is@tuv.it A1400 AIR RDT 532119 04 - Rev. C...
Description: Automation for linear sliding door with 1 or 2 leaves Model: A1400 AIR RDT KIT; A1400 AIR RDT PA comply with the following applicable EU legislations: EMC Directive 2004/108/EC Directive ROHS 2 2011/65/EU...
Linear sliding door with 1 or 2 leaves Model: A1400 AIR RDT KIT the essential requirements of the Machinery Directive 2006/42/EC (including all applicable amendments) applied and met are: RESS 1.1.2, 1.1.3, 1.1.4, 1.1.5, 1.1.6, 1.2.1, 1.2.3, 1.3.4, 1.5.1, 1.5.11, 1.5.13, 1.6.3, 1.7.1, 1.7.1.2, 1.7.4 and that the relevant technical documentation has been compiled in compliance with part B of Annex VII.
FAAC disclaims any liability involving the automation’s safety and proper operation in the event non-original components are used FAAC. For the supplyA1400 AIR RDT CS, FAAC a System Register form is provided. A1400 AIR RDT 532119 04 - Rev. C...
It indicates that a tool with torque adjustment is required where necessary for safety reasons. TIGHTENING TORQUE VALUE The pictures specify the tool and the tightening torque in Nm. E.g.: HEX WRENCH 6 set at 2.5 Nm A1400 AIR RDT 532119 04 - Rev. C...
Use pallet trucks. Use forklift trucks. 4 Symbols: signs on the product 20 kg is the MAX weight that 1 person can lift. Obligation to read the instructions Kg ____ WEIGHT of the load. A1400 AIR RDT 532119 04 - Rev. C...
1 2.1 INTENDED USE 2.2 UNAUTHORISED USE Systems FAAC series A1400 AIR RDT make it possible to operate auto- It is forbidden to: matically, manage and control operation of sliding one- or two-leaf - use the automation for uses other than THE INTENDED USE;...
2-1. Sale code Product name IDENTIFICATION NUMBER example: 1050400000 1050400000 0114 0114 0001 0001 Sale code Progressive no. of the month of production Month and year of production (mm/ 2 A1400 AIR RDT 532119 04 - Rev. C...
2.4 TECHNICAL SPECIFICATIONS 7 Technical specifications MODEL A1400 AIR RDT single leaf A1400 AIR RDT double leaf Length * [mm] from 1750 to 4600 from 2200 to 6100 Depth * [mm] Total depth with self-supporting beam * [mm] Height * [mm] Weight** [kg] MIN.
Automations FAAC of the A1400 AIR RDT series may be purchased - Required inspections and arrangements (§ 3) with the following supply methods: - Installation of the door wall frame (§ 8) with FAAC - TK50 or TK20 - Automation in kit: A1400 AIR RDT KIT profiles - Assembled automation: A1400 AIR RDT PA - Installation of the head section (§...
- 2 Sides to fasten the head section to the side walls. It is obligatory to use the belt FAAC for A1400 AIR RDT - Transom Profiles to lock any transom panel installed above the self-supporting profile.
Page 17
TK50 - Sliding shoes with bracket - OPTIONAL For fastening to wall or fixed leaf (supplied in a PAIR). TK50 - Swivel sliding shoes - OPTIONAL For fastening to the floor (supplied in a PAIR). A1400 AIR RDT 532119 04 - Rev. C...
Comply with the following heights from the ground: - control accessories = minimum 150 cm - emergency buttons = max 120 cm A1400 AIR RDT 532119 04 - Rev. C...
SINGLE PACKAGE RISKS PERSONAL PROTECTIVE EQUIPMENT REQUIRED TOOLS For manual lifting, arrange for 1 person every 20 kg to be lifted. A1400 AIR RDT 532119 04 - Rev. C...
5. CUT THE PROFILES In case of A1400 AIR RDT KIT supply, the profiles must be cut to the indicated measure. This operation is performed in the shop. After cutting, assemble the components to the support profile. Handling instructions: 19 .
1. Fasten the support profile to the self-supporting profile 5- : In case of A1400 AIR RDT KIT supply, the components must be fitted - start fastening at a vertical slot at one end and a horizontal slot onto the support profile. This operation is performed in the shop.
2. Check correct position resting on the profile - 6- and tem- porarily fasten each mechanical stop 6- . After assembling the leaves, the stops’ positions must be adjusted. 6 A1400 AIR RDT 532119 04 - Rev. C...
1. Mount crescents on auxiliary motor 1 1 - . 2. Insert the motor in the side. 3. Fasten by means of the 5 plates with screws 1 1 - . 9 1 0 11 A1400 AIR RDT 532119 04 - Rev. C...
15- ). If installation of the external release is required, use suitable key but- tons. Insert the release cable in the suitable housing in the motor block. 14 15 A1400 AIR RDT 532119 04 - Rev. C...
Check the label on the emergency battery with date and logo through the window on battery support plate .1 8 - . 17 IDENTIFICATION NUMBER example: 75501500 75501500 2015 2015 Sale code year of manufacture (yyyy) 18 A1400 AIR RDT 532119 04 - Rev. C...
7. ASSEMBLE THE FRAME A1400 AIR RDT CS RISKS PERSONAL PROTECTIVE EQUIPMENT REQUIRED TOOLS glass shims Ø 8 mm A torque wrench must be used to achieve the specified fastening torques (Nm). 19 When ordering the door frame take into account that opening safety...
Ensure there are no hydraulic coils or electrical conduits under the floor at the planned drill points. 3. Measure the door frame and compare them with the opening measurements. 4. Check floor levelness with a spirit level. 2 3 A1400 AIR RDT 532119 04 - Rev. C...
It is nevertheless recommended to fit a tie rod in central position also for lengths less than 3000 mm. Screws and dowels not supplied. 2 8 Tie rod not supplied. * minimum 70 mm 2 9 A1400 AIR RDT 532119 04 - Rev. C...
The number of required tie rods depends on profile length: arrange one tie rod every 2500 mm. 30 31 32 Tie rod not supplied. * minimum 70 mm 33 A1400 AIR RDT 532119 04 - Rev. C...
When the leaf is open or closed, the shoe must be fully inside the lower leaf profile. The distance between shoe and lower profile must be 4mm (ref. 4 3 4-3 5-3 6). 3 4 36 A1400 AIR RDT 532119 04 - Rev. C...
- 11 0 - 10 9 for DOUBLE leaf automations For manual lifting, arrange for 1 person every 20 kg to be lifted. 38 Adjust the counter wheel 52 3 9. A1400 AIR RDT 532119 04 - Rev. C...
5. Adjust steel cable tension with the slot so that the two branches are parallel. 6. After that lock in position with the screw resting on the wheel shaft 4 0 - . 4 0 A1400 AIR RDT 532119 04 - Rev. C...
The end part will be 50mm 42- 2. After that correctly position the rods, set the telescopic profile abutting with the main profile and fix it with the hex screws with washer 4 2- 4 2 A1400 AIR RDT 532119 04 - Rev. C...
4. After that fix the plates with the screws supplied 43- . 4 3 9.8 PREPARING EXTERNAL CARRIAGES 1. Assemble the supports and bracket 44- 2. Mount the belt connection unit 44 - . 4 4 A1400 AIR RDT 532119 04 - Rev. C...
Page 37
4. Fit the bracket to secure the steel cable of the external carriages 45- . 4 5 Mount the assembled leaf carriage unit on the profile 46 - 46 4 7 A1400 AIR RDT 532119 04 - Rev. C...
4 8 - . 4. Secure the cable under the brackets using the supplied screws 48- . 4 8 A140 AIR T DX A140 AIR T SX 4 9 A1400 AIR RDT 532119 04 - Rev. C...
Manually move the leaves to ensure the counter wheel runs freely along the entire stroke. Ensure there are no friction points with the surface of the support profile. 5 1 52 A1400 AIR RDT 532119 04 - Rev. C...
Ø internal 6 mm Ø external 8 mm Ø 6.5 mm with 45° flaring Ø 5.0 mm with M6 tapping Ø 7.0 mm 2 x M8 2 x M6 x 25 UNI 5933 5 3 A1400 AIR RDT 532119 04 - Rev. C...
Page 41
Check leaf verticality. When the leaf is open or closed, the shoe must be fully inside the lower leaf profile. Distance between glass and lower shoe must be 4mm 54- . 54 A1400 AIR RDT 532119 04 - Rev. C...
For double leaf automations: 55. For single leaf automations: 55. Double leaf Transit space Transit space Left opening single leaf Transit space Transit space Right opening single leaf Transit space Transit space 5 5 A1400 AIR RDT 532119 04 - Rev. C...
PERSONAL PROTECTIVE EQUIPMENT It is obligatory to use the FAAC belt for A1400 AIR RDT 1. Insert one end of the belt around the pulley of Motor_1. Fasten the two ends with fittings 5 6(1) and screws 56(2).
2. Apply a 1 kg weight in the centre of the belts lower section. 3. Adjust belt tensioning until obtaining the measurement of arrow f corresponding to the instructions in 9. Single leaf - RH opening 1 kg A1400 AIR RDT 532119 04 - Rev. C...
2. Close the leaf. 3. Bring the mechanical stop pad and carriage into contact 59- . 4. Tighten the 2 grub screws to lock the mechanical stop 59- . 59 6 0 A1400 AIR RDT 532119 04 - Rev. C...
3. Fasten each side profile with the 3 screws provided 61 - . 6 1 11.5 INSTALL THE CASING BRACKETS 1. Mount the 3 brackets and fasten them with the screws provided 62- . 6 2 A1400 AIR RDT 532119 04 - Rev. C...
The markings on the casing allow it to be adapted to varying leaf thickness. The breaking points 63- make it possible to elimi- nate the profile section in excess. » » 63 A1400 AIR RDT 532119 04 - Rev. C...
To disassemble the motor block: act carefully on the motor retainer to avoid breaking it, leverage with a slotted screwdriver between retainer hook and motor block 6 4 - . 6 4 6 5 A1400 AIR RDT 532119 04 - Rev. C...
67 11.11 MOUNT THE CABLE GLAND GUIDES The guides prevent interference between cables and moving parts. Install guides for running electrical cables inside the support profile 67 - 6 8 A1400 AIR RDT 532119 04 - Rev. C...
(Open impulse) * input not active OPEN: DL11 (BLUE) accessories power supply (+ 24V * present absent VACC: LED statuses: flashing * = standby condition in sleep:off with blinking every 5 s A1400 AIR RDT 532119 04 - Rev. C...
Input + external detector in current XDT3 External detector input NC/NO contact or Frequency M1 Motor connection GND Accessories power supply negative and Common contacts +24V accessories power supply J12 - MOTOR_1 ENCODER M1 Motor encoder connection A1400 AIR RDT 532119 04 - Rev. C...
ERROR 26 on the display and on SDK EVO. With SDK EVO the motor block operation may be programmed with several options. In the event of mains power failure, if the battery runs out the block remains on. DL11 74 A1400 AIR RDT 532119 04 - Rev. C...
With SDK EVO the motor block operation may be programmed with several options. In the event of mains power failure, if the battery runs out the motor block XM LOCK is disconnected. DL11 75 A1400 AIR RDT 532119 04 - Rev. C...
With PO partial opening higher than 80%, operation of grey the safeties has no effect. power supply green XBFA outside of door DL11 inside of door exit - escape route 8 0 A1400 AIR RDT 532119 04 - Rev. C...
(partial opening). The STOP or LOW ENERGY mode can be selected. With PO partial opening higher than 80%, operation of the safeties has no effect. outside of door inside of door exit - escape route 8 3 A1400 AIR RDT 532119 04 - Rev. C...
8 7 - O1 Open Collector output with Max load 100mA to be connected between 01 and V. - O2 relay contact with Max load 2A to be connected between O2 and O2. A1400 AIR RDT 532119 04 - Rev. C...
- any connected control devices. The battery must be charged exclusively by using the electronics SAVING THE CONFIGURATION module for A1400 AIR RDT At the end of functional tests, download the full configuration of 13.1 SYSTEM POWER SUPPLY AND SETUP the system.
Power failure during programming If power supply fails while programming is ongoing, UNSAVED modifications must be performed again. Immediately exit programming During programming, press simultaneously F and - until programming exit is activated: function RESET/SETUP A1400 AIR RDT 532119 04 - Rev. C...
Page 65
PUSH TIME on OBSTACLE 1 . 0 1 . 0 SAFETY INPUT TEST S1 Adjustable from s to Not displayed if Step = 0.1 s = test enabled = test not enabled A1400 AIR RDT 532119 04 - Rev. C...
Page 66
The internal detector is disabled immediately after opening and in any case upon expiry of the set delay. Adjustable from Step = 1 s A1400 AIR RDT 532119 04 - Rev. C...
Page 67
SDK EVO offers a wider number of options compared to the board. The board does not display the values it does not have and shows them all as EP (External Program). Programming with the board lets you overwrite values EP, choosing an available value with +/ - . A1400 AIR RDT 532119 04 - Rev. C...
PARTIAL NIGHT-TIME partial opening and closure again CLOSED no effect no effect total opening after night pause time PARTIAL OPENING OPEN no effect no effect no effect no effect PARTIAL A1400 AIR RDT 532119 04 - Rev. C...
PHARMACY OPEN input - activation of this input lights up the SIC_OP red LED on the board. - this type of input may only be activated on I1, I2, I3 and I4 inputs A1400 AIR RDT 532119 04 - Rev. C...
Page 70
- With inactive contact of both inputs configured in this way the NIGHT-TIME mode is exited. - in an input configured in this way with SDK EVO and LKEVO the functions can be modified, except NIGHT-TIME. A1400 AIR RDT 532119 04 - Rev. C...
C1=16 C1=16 CI=17 CI=17 NO NO (NC input) (NO input) (programmable only (programmable from board or from SDK EVO ) from SDK EVO ) 8 8 A1400 AIR RDT 532119 04 - Rev. C...
- set from SDK EVO the number of obstacles in closing = 0 (“Consecu- tive obstacles” 9 2). For details refer to standard EN 16005:2012. It is possible to use SDK EVO. A1400 AIR RDT 532119 04 - Rev. C...
To restore operation, remove the cause and perform a RESET. + alert code DL4 RESET/SETUP + error code DL4 A1400 AIR RDT 532119 04 - Rev. C...
Page 74
Consecutive obstacles in opening Check for and remove the obstacle in opening. Board data being deleted Restore procedure executed. * When the condition is restored, this error disappears without requiring a RESET. A1400 AIR RDT 532119 04 - Rev. C...
Page 75
1 7 AUX Errors AUX Errors Intervention required 2 00 2 0 0 UC Failure (Corrupted FW or Corrupted RAM) Carry out board reset; if the error persists replace the board. A1400 AIR RDT 532119 04 - Rev. C...
- door set in NIGHT-TIME function - door set in MANUAL function - active internal or external release - active emergency entry - motor or encoder not connected, not powered or faulty A1400 AIR RDT 532119 04 - Rev. C...
The door automatically performs a TEST every time that: - it exits the NIGHT-TIME function - it exits the MANUAL function WHEN IS RESET NECESSARY After automation lock due to: - board in error condition with request to RESET A1400 AIR RDT 532119 04 - Rev. C...
UPLOAD must be performed 21 Firmware and programming file names 1400RD.hex board firmware 1400RD.prg board programming 1400RD.tmr Timer programming SDKEVO.hex firmware SDK EVO SDKEVO_L.bin language update on SDK EVO LKEVO.hex firmware LKEVO A1400 AIR RDT 532119 04 - Rev. C...
² ² the LKEVO might have blocked function keys. MANUAL E1400 RD V RX TX G V RX U/UTP CAT.5 4x2xAWG24 TX RX G K G V LKEVO 9 0 A1400 AIR RDT 532119 04 - Rev. C...
5. In the event LKEVOis connected to a board A1400 AIR RDT in which an unintended function is programmed, a different function is overridden 17.3 SPECIAL FUNCTIONS as indicated: RESET: - from AUTOMATIC ONLY PARTIAL ENTRY Reset clears errors in the memory.
Page 82
Motion too slow Corrupted data Switching power supply unit fault Consecutive obstacles in closing AUX Motor fault Motor block fault Motor rotation error AUX motor rotation error _AUX board fault A1400 AIR RDT 532119 04 - Rev. C...
Page 83
SETUP in progress Safety device test failed 2 5 Firmware Version ³ ³ Firmware Version FW 1.0 FW 1.1 FW 1.2 FW 1.3 FW 2.0 FW 2.1 FW 2.2 FW 2.3 A1400 AIR RDT 532119 04 - Rev. C...
2. Break off the cable run insert 9 1- . 3. Mark points on the wall 91- and fasten the support with A1400 AIR RDT THUR 20/03/14 adequate screws. AUTO TWODIR TOTAL BEFORE CONNECTING THE DEVICE, disconnect the power supply and the emergency battery of the automation.
2 buttons simultaneously for 5 s: - time timer active 5” 5” SDK EVO blocked current indications RESET A1400 AIR RDT 5” 5” THUR 20/03/14 AUTO BIDIR TOTAL 18.5 PASSWORD To perform some commands the 4-digit PASSWORD must be entered.
HOME PAGE 1. To access the selection menu of the operation mode, press the corresponding button in HOME PAGE 94. A1400 AIR RDT 2. With selection buttons 9 5 you can set: THUR 20/03/14 - the Automatic or Door open operation...
18.7 FUNCTION MENU HOME PAGE 1. To access the function menu, press the corresponding button in HOME PAGE 96. A1400 AIR RDT 2. The password is requested: enter OPERATOR or INSTALLER THUR 20/03/14 password. AUTO BIDIR TOTAL 3. The display shows functions (4 at a time) 97.
1 ERRORS E1400 RD APP 200 UC FAILURE 41 TIME LOSS 2 AUX ERRORS VER.xx WARNINGS AUX APP 201....221 42.....79 VER.xx 80 NON STANDARD 222 TEST VMAIN SDK EVO APP PROGRAM. VER.xx A1400 AIR RDT 532119 04 - Rev. C...
Page 89
DISABLED AUX TEST TIME ENABLED BOARD'S DISPLAY FUNC. SAF OPENING BATTERY KIT FUNCTION INTRUSION LAST MOVEMENT PARTIAL PHARMACY NIGHT-TIME FUNCTION SDK EVO KEY LAST MOV. NIGHT CONSECUTIVE OBSTACLES TEST ERROR NOT AVAILABLE A1400 AIR RDT 532119 04 - Rev. C...
- Internal current - - 13 Partial 13 Partial - Internal frequency - - 14 Opening safety 14 Opening safety - Disabled 3. Select the function for Sensor E (External Sensor): - Disabled A1400 AIR RDT 532119 04 - Rev. C...
Page 91
3 TIMING TIMING PROGRAMMING Choose and modify the parameter. The complete list with relevant default and range of values is: - 1 PAUSE TIME 2s (0-30) - 2 NIGHT PAUSE TIME 10s (0-240) A1400 AIR RDT 532119 04 - Rev. C...
Page 92
The block due to obstacles in opening cannot be DISABLED. 1 Default Configuration - ACTIVE (default configuration is present) - NO (default configuration has been modified) To reset all parameters to default settings press the OK button and confirm. A1400 AIR RDT 532119 04 - Rev. C...
- Auto Twodir Total (1) Available options are: - Auto Out Total (2) - Enabled - Auto Twodir Partial (3) - Disabled - Auto Out Partial (4) - Open Total (5) - Open Partial (6) A1400 AIR RDT 532119 04 - Rev. C...
If the PSW has not been repeated correctly, the display continues requesting the new password and the confirmation. 4. Proceed in the same way for the other desired JOLLY (WILD CARD) time SLOT. A1400 AIR RDT 532119 04 - Rev. C...
MENU 9 INFO E1400 RD BOOT VER.xx INFO E1400 RD APP VER.xx AUX APP VER.xx SDK EVO APP VER.xx The display shows the firmware versions of the control board and installed devices. A1400 AIR RDT 532119 04 - Rev. C...
Centre. The warranty shall be forfeited in the event of tampering with components. For replacements, use only FAAC original spare parts. » » Motor_1 The batteries and electronic components must not be disposed of with household waste but delivered to authorised disposal and recycling centres.
Page 99
» » The battery must be charged exclusively by using the electronics module for A1400 AIR RDT 1. Disconnect the battery from the board E1400 RD. 10 1 2. Loosen the 2 screws with washer 1 0 1 - and disassemble the battery.
- efficiency of safety detectors (the radar field must be free and adequately sized with respect to passage flow) - operation of EMERGENCY button (if present) and any other ac- cessories installed. A1400 AIR RDT 532119 04 - Rev. C...
A140 AIR TELESCOPIC SINGLE LEAF RIGHT AND LEFT OPENING DRILLING TEMPLATE FOR TELESCOPIC PROFILE AND TELESCOPIC PROFILE FIXING ROD CUTTING 110 A1400 AIR RDT 532119 04 - Rev. C...
A140 AIR TELESCOPIC DOUBLE LEAF DRILLING TEMPLATE FOR TELESCOPIC PROFILE AND TELESCOPIC PROFILE FIXING ROD CUTTING 112 A1400 AIR RDT 532119 04 - Rev. C...
Page 111
He/she must request intervention by the installer/ The door A1400 AIR RDT runs a system test in 24h: the door opens maintenance technician. and closes. make sure the system’s maintenance is carried out according to the A system test is immediately run when changing from NIGHT-TIME or instructions provided in this manual.
21.2 SELECTION MENU system data and current statuses 1. To access the selection menu of the operation mode, press the A1400 AIR RDT THUR 20/03/14 corresponding button in HOME PAGE . AUTO TWODIR TOTAL 2. With the selection buttons you can set:...
Page 114
- press OK to go back to the home page. - operating mode - time PASSWORD timer active SDK EVO blocked current indications INCORRECT PASSWORD A1400 AIR RDT THUR 20/03/14 AUTO BIDIR TOTAL 14:30 go to SELECTION set NIGHT-TIME menu mode...
6. The ALARMS are displayed with a code of blinking LEDS alternating to the operating mode in progress To see the type of ALARM see 23 present in the manual. A1400 AIR RDT A1400 AIR RDT 532119 04 - Rev. C...