Precaution For Installation - Yoshitake GD-28S-NE Product Manual

Pressure reducing valve
Table of Contents

Advertisement

4.2 Precaution for installation

Please refer to "2. Dimensions and Weights." for product weight.
1.
* Failure to follow this notice may cause a falling accident of the product, resulting in an injury.
2.
When installing a safety relief valve for equipment protection on the outlet side of the product, connect
a blow-off pipe to the outlet side of the safety relief valve, and lead it to a place where there is no risk
of physical damage even if fluid blows out.
* Failure to follow this notice may result in injury and scalds in the event that high temperature fluid
blows out.
1.
Do not disassemble the product unless it is necessary.
* Unnecessary disassembly prevents the product from functioning properly.
2.
Before installing the product in the piping, be sure to remove foreign substances and
piping. Keep foreign substances from entering the piping, including seal tape or liquid seal agent for
piping connection.
*Ingress of foreign substances, scales or seal agent into the product leads to valve leakage or
malfunction of the product.
* Repairs caused by foreign substances or scales will be charged even during the warranty period.
3.
If components having a negative influence on internal parts are included in fluid or surroundings,
deterioration of rubber parts is accelerated and then outside leakage or functional disorder is caused.
4. Be sure to install a strainer on the inlet side of the product of nominal size 65A to 100A.
*Ingress of foreign substances or scales into the product leads to malfunction of the product. It is
recommended to use a strainer of 60 mesh or more.
5.
Install a safety relief valve for equipment protection on the outlet side of the product.
* Failure to follow this notice may result in damage of the equipment.
6. Be sure to install pressure gauges on both inlet and outlet sides of the product.
* Failure to follow this notice hampers correct pressure adjustment.
7.
If a quick operating valve such as a solenoid valve is installed, place it at a distance of at least 3 meters
from the product.
* Failure to follow this notice may result in malfunction or a drastically shortened service life of the
product.
8.
Install the product properly by checking the inlet, outlet and proper posture.
* Installing the product in wrong directions prevents the product from functioning properly.
9.
Install pipes so that excessive load, torque or vibration is not applied to the product.
10. Make sure that pipes 3m before and after the product, the inlet side and outlet side, are of the same
diameter.
* If the pipe diameter is narrowed immediately before or after the product, the flow velocity may increase
and result in malfunction or a drastically shortened service life of the product.
11. The product can be installed either horizontally or vertically.
12. A space more than the value shown as H
A space more than the value shown as H
strainer (nominal size 20A to 50A).
13. For two-stage pressure reduction, keep a distance of at least 3 meters between each product.
*Failure to follow this notice may prevent the product from functioning properly due to malfunction.
Warning
Caution
in the table below is required for disassembly and inspection.
2
in the table below is required for the inspection of the built-in
3
8
scales
from the
EPDT-351

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gd-29s-ne

Table of Contents