therefore be factored into the measurement. It has been scientifically established
that a 10mm adjustment provides an accurate overall reading.
The height shown on the indicator console in mm is the number of light paths
broken at any instant, multiplied by 20mm, plus the 10mm adjustment.
For example:
• 7 light paths broken records as = 140mm (7 x 20mm)
• PLUS the 10mm adjustment
• = 150mm