Main Filter Change - Kemper VacuFil Compact Operating Manual

Table of Contents

Advertisement

Available languages

Available languages

Disconnect the pressure supply, if present, and let the compressed air
present in the product flow out via the condensate drain valve.

7.2.4 Main filter change

Carry out the main filter replacement as follows:
1. Switch off the product at the rotary switch.
2. Disconnect the product from the power supply by unplugging.
3. Depending on the fill level, it is recommended to change the dust
collection container (Pos. 3) beforehand. (see "Maintenance" chapter)
Pos. Description
1
Maintenance cover
2
Clamp fastener (2x)
4. Open the maintenance cover (Pos. 1) by folding down the two clamp
fasteners (Pos. 2).
5. Carefully tilt the product according to the figure and place it on the
ground. The maintenance cover (Pos. 1) with the dust collection
container (Pos. 3) remains on the floor.
1502872-02
Fig. 24: Opening the maintenance cover
Tab. 27: Access to the main filter
- 86 -
Pos. Description
3
Dust collection container
EN