Changing The Filter - Safety Instructions - Kemper VacuFil Compact Operating Manual

Table of Contents

Advertisement

Available languages

Available languages

Pos.
Description
1
Vent – motor cooling
(magnetic)
Perform the filter mat replacement as follows:
1. Switch off the product at the rotary switch.
2. Detach the vent (Pos. 1) from the holder by pulling on the vent slots.
3. Remove the contaminated filter mat (Pos. 2) from the holder and
dispose of it in accordance with the applicable regulations.
4. Insert a new filter mat (Pos. 2) into the holder.
5. Insert the vent into the holder on the product.
6. Put the product back into operation. (see also "Commissioning" chapter)
7.2.3 Changing the filter – Safety instructions
The life of the filter inserts depends on the type and amount of deposited
particles.
As the dust accumulation in the filter increases, its flow resistance
increases and the extraction capacity of the product decreases.
Even with products that may have automatic filter cleaning, adhering
deposits can reduce the extraction capacity.
A filter change is required.
1502872-02
Fig. 23: Filter mat replacement, motor cooling
Tab. 26: Filter mat replacement, motor cooling
Pos.
Description
2
Filter mat
- 84 -