Activation Codes; Displaying The Product Id; Automatic Start/Stop; Cleaning (Only Products With Filter Cleaning) - Kemper VacuFil Compact Operating Manual

Table of Contents

Advertisement

Available languages

Available languages

EN
Automatic extraction capacity regulation activated
If the optionally available extraction capacity regulation is activated by
means of an activation code, the control constantly monitors the set
extraction capacity. If the extraction capacity drops, e.g. when the filter is
saturated, the control automatically regulates the speed of the side
channel compressors so that the set extraction capacity is always
guaranteed at the extraction torch.

6.2.3 Activation codes

Advanced functions can be activated by entering activation codes.
Activation codes can be entered a maximum of 5 times in succession. A
correct code is signalled by green flashing, an incorrect code by red
flashing of the signal lamp (Pos. 4). If an incorrect code has been entered 5
times in succession, the code entry is blocked for 60 seconds. The menu
item "SEC" cannot be activated then. Any further incorrect entry will then
lock it again for 60 seconds.

6.2.4 Displaying the product ID

To query the three-digit product ID number, press and hold the rotary
switch (Pos. 6) for more than 5 seconds.
The ID is required when, for example, the activation codes are to be
entered.

6.2.5 Automatic start/stop

As soon as the start/stop module (optional) is connected to the connection
socket (Pos. 2), the product switches off and automatically switches to
start/stop mode. In start/stop mode, the LED signal lamp flashes green.
When the start/stop module is activated by a welding process, the product
starts. After the welding process is finished, the product switches off again
after an adjustable run-on time. (preset run-on time 30 seconds)

6.2.6 Cleaning (only products with filter cleaning)

Some product variants have a manual cleaning function for the filter
cartridge.
When the filter cartridge has reached a certain saturation, the LED display
(Pos. 5) shows "CLE". Filter cleaning is required!
1502872-02
- 78 -

Advertisement

Chapters

Table of Contents
loading

Table of Contents