Error Codes - Digital Led Display - Kemper VacuFil Compact Operating Manual

Table of Contents

Advertisement

Available languages

Available languages

2
Connection socket for
start/stop sensor
3
Signal horn
The digital LED display (Pos. 5) shows errors and information codes. A
distinction is made between:
Error codes: In the event of an error, the product switches off
immediately. The LED signal lamp (Pos. 4) lights up red.
Troubleshooting measures are required
Warning codes: If there are warnings, the product continues to run. The
LED signal lamp (Pos. 4) flashes magenta and after 5 minutes a warning
tone sounds. Product functions may no longer be active. If several
warning codes are active, they are shown one after the other on the
digital LED display. After all warning codes have been displayed, they
reappear after 5 minutes. Warnings can be called up by turning and
pressing the rotary pushbutton (Pos. 6) and hidden for 5 minutes.
7.4 Error codes – digital LED display
Error
Error cause
code
F01
Frequency converter
overcurrent
F02
Frequency converter
overvoltage
F03
Frequency converter
undervoltage
F04
Frequency converter
overtemperature
F60
Internal frequency
converter fault
F 90
No communication to
the frequency converter
F91
Motor temperature too
high
F92
Control temperature too
high
1502872-02
5
6
Tab. 30: Operating control
Reaction of the
control
Product switches
off
Product switches
off
Product switches
off
Product switches
off
Product switches
off
Product switches
off
Product switches
off
- 91 -
Digital LED display
Inductive one-button
operation (rotary switch)
Note
Check the voltage
supply
Check the voltage
supply
Check the voltage
supply
Check the voltage
supply
Contact service
department
Contact service
department
Allow product to
cool down
Allow product to
cool down