Download Print this page

Quantum QT-730 Series Installation And Operation Manual

Fixed non-float-top enclosed base radiographic table

Advertisement

Quick Links

Model QT-730 Series
Fixed Non-Float-Top
Enclosed Base Radiographic Table
Installation and Operation
Manual
Manual Part No. DC30-003 Revision B

Advertisement

loading

Summary of Contents for Quantum QT-730 Series

  • Page 1 Model QT-730 Series Fixed Non-Float-Top Enclosed Base Radiographic Table Installation and Operation Manual Manual Part No. DC30-003 Revision B...
  • Page 2 This manual is copyrighted and all rights are reserved. No portion of this document may be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine readable form without prior consent in writing from Quantum Medical Imaging, LLC.
  • Page 3 Revision History REVISION HISTORY REVISION DATE TYPE OF MODIFICATION 9/1/00 Initial Release. 2/15/01 Added UL Mark LIST OF EFFECTIVE PAGES Page Page Page Number Number Number i - x 1-34 Model QT-730 Radiographic Table...
  • Page 4 Revision History THIS PAGE INTENTIONALLY LEFT BLANK Model QT-730 Radiographic Table...
  • Page 5: Table Of Contents

    Table of Contents Table of Contents Section 1, Introduction Section 2, Specifications Section 3, Assembly & Installation Section 4, Operation Section 5, Maintenance Model QT-730 Radiographic Table...
  • Page 6 Table of Contents THIS PAGE INTENTIONALLY LEFT BLANK Model QT-730 Radiographic Table...
  • Page 7 Safety Notices WARNING Quantum Medical Imaging, LLC disclaims all responsibility from any in- jury resulting from improper application of this equipment. This equipment is sold to be used exclusively under the prescribed direc- tion of a person who is licensed by law to operate equipment of this na- ture.
  • Page 8 Safety Notices REGULATORY COMPLIANCE This certified Quantum Medical Imaging, LLC medical device has been designed, manufactured, and calibrated to comply with governing Federal Regulations 21 CFR Subchapter J and the performance standards attendant thereto. Upon installation, all certified products require the filing of Form FD-2579 "Report of Assembly of a Diagnostic X-Ray System"...
  • Page 9 Warranty Information WARRANTY STATEMENT Quantum Medical Imaging, LLC (herein known as “QMI”) warrants to buyer that any new product manufactured by QMI will be free from defects in material and manufactur- ing and conform substantially to applicable specifications in effect on the date of ship- ment when subjected to normal, proper and intended usage by properly trained person- nel.
  • Page 10 2) Failure of Buyer/Dealer to provide the proper incoming power required to sup- port the equipment in accordance with the recommendation of QMI. 3) Any modification of product performed by a party other than Quantum Medical Imaging. 4) Combining incompatible products.
  • Page 11 B) By making available any necessary repaired or replacement parts or as- semblies. Quantum Medical Imaging shall have the option to furnish either new or ex- change replacement parts or assemblies. All returned parts shall become the property of Quantum Medical Imaging.
  • Page 12 Warranty Information THIS PAGE INTENTIONALLY LEFT BLANK Model QT-730 Radiographic Table...
  • Page 13: Section 1, Introduction

    Chapter INTRODUCTION...
  • Page 15 Chapter 1 Introduction OVERVIEW This manual provides information for installing, operating, and maintaining Quan- tum Medical Imaging’s Fixed, Non-Float-Top, Radiographic Table, Model QT-730 NOTE (hereinafter referred to as the Radiographic Table). It is imperative that all safety procedures described in this manual be strictly adhered to in order to ensure the The user should safety of both patient and user.
  • Page 16 Chapter 1 Introduction MAIN COMPONENTS See Figure 1. The Model QT-730 Radiographic Table contains: Tabletop Receptor Cabinet Receptor Cabinet Lock Lever Compliance Label Table Base Figure 1. Radiographic Table, Model QT-730 Series Model QT-730 Radiographic Table...
  • Page 17: Section 2, Specifications

    Chapter SPECIFICATIONS...
  • Page 19 Chapter 2 Specifications PHYSICAL SPECIFICATIONS The following are physical specifications for the Radiographic Table (see Figure Tabletop Specifications Length: 74.0 inches (1879.6 mm)* • Width: 28.0 inches (711.2 mm) • Height: 31.75 inches (806.5 mm) • Material Type: Fiber Resin (phenolic) •...
  • Page 20 Chapter 2 Specifications Figure 2. Model QT-730 Dimensions Model QT-730 Radiographic Table...
  • Page 21 • to sea level COMPATIBILITY STATEMENT Model QT-730 Radiographic Table is compatible with all Quantum Medical Imaging, LLC manufactured tubestands, wall stands, and high-voltage x-ray generators, and with other manufacturer’s equip- ment with equivalent means for indication of SID and perpendicular- ity.
  • Page 22 Chapter 2 Specifications THIS PAGE INTENTIONALLY LEFT BLANK Model QT-730 Radiographic Table...
  • Page 23: Section 3, Assembly & Installation

    Chapter ASSEMBLY & INSTALLATION...
  • Page 25 Should there concealed dam- age claim if filed be a shortage of parts, notify Quantum Medical Imaging’s Service Department. after 15 days from date of receipt of mer- chandise.
  • Page 26 Chapter 3 Assembly & Installation INSTALLATION INSTRUCTIONS NOTE To assemble and install the Radiographic Table, refer to Figures 3 through 10. Prior to install- ing the Radio- Table Assembly graphic Table, the area of the The table typically is shipped with the Table Top Frame already attached to the floor on which Table Base, in which case you can skip to step 3.
  • Page 27 Chapter 3 Assembly & Installation 3. Install the Receptor Cabinet as follows: a. Loosely attach the two (2) Front Receptor Bearing Brackets to the Re- ceptor Cabinet, as shown in Figure 4, using three (3) 1/4-20 x 3/4” pan head screws (bracket with handle mounts to right side of cabinet). b.
  • Page 28 Chapter 3 Assembly & Installation FRONT RECEP- TOR BEARING BRACKET Figure 5. Front Receptor Bearings Resting on Rail Figure 6. Receptor Cabinet Resting on Table Base Model QT-730 Radiographic Table...
  • Page 29 Chapter 3 Assembly & Installation INSERT REAR RECEPTOR BEARINGS ON TRACK THROUGH SLOT IN BEARING RAIL Figure 7. Insert Left and Right Receptor Bearings on Track LEFT AND RIGHT REAR RECEPTOR BEARING BRACKETS Figure 8. Position Receptor Cabinet for Rear Receptor Bracket Installation Model QT-730 Radiographic Table...
  • Page 30 Chapter 3 Assembly & Installation e. Slowly roll the Receptor Cabinet along the bearing rails while checking for smoothness. The mounting holes on the Receptor Bearing Brackets are slotted to provide adjustment. Adjust the brackets as required until receptor travel is satisfactory (smooth and even through full travel), then fully tighten all bracket screws.
  • Page 31 Chapter 3 Assembly & Installation If the tubestand to be used provides transverse travel of the x-ray tube rela- tive to the table, set the tube transverse travel in the center detent position prior to performing this alignment. 1. With the collimator parallel to the table top (0° rotation angle), turn on the collimator light.
  • Page 32 Chapter 3 Assembly & Installation 7. Move the tubestand and Receptor Cabinet simultaneously to check for con- tinuous alignment of the narrow beam of light and the cassette center line. 8. If the light beam and cassette center line are in proper alignment, verify that table is still level.
  • Page 33: Section 4, Operation

    Chapter OPERATION...
  • Page 35 Chapter 4 Operation Radiographic Table Operation Operation of the Radiographic Table involves moving the Receptor Cabinet (cassette holder) longitudinally (i.e., left or right). This is accomplished by unlocking (pressing down) the Receptor Cabinet Lock Release Lever (see Figure 11), attached to the Receptor Cabinet, and then moving the cabinet to the desired position.
  • Page 36 Chapter 4 Operation CASSETTE TRAY OPERATION The Radiographic Table is equipped with either a Midwest or Poersch cassette tray, depending on the system ordered. The following paragraphs describe the operating instructions for each. Additional information is contained in the cas- sette tray manufacturer’s documentation, which is shipped with the table.
  • Page 37 Chapter 4 Operation 8. Push tray into Receptor Cabinet. The cassette is now in exposure posi- tion. Loading Cassette Tray (Poersch Type) To load a film cassette into a “Poersch” type cassette tray, proceed as fol- lows: 1. Pull cassette tray from Receptor Cabinet using tray handle (see Figure 13).
  • Page 38 Chapter 4 Operation THIS PAGE INTENTIONALLY LEFT BLANK Model QT-730 Radiographic Table...
  • Page 39: Section 5, Maintenance

    Chapter MAINTENANCE...
  • Page 41 Chapter 5 Maintenance OVERVIEW The Radiographic Table will function reliably when maintained according to the in- structions provided in this chapter. WARNING! Only properly trained service personnel should se WARNING! Only properly trained service personnel should se WARNING! Only properly trained service personnel should ser- vice or maintain this equipment.
  • Page 42 Chapter 5 Maintenance A complete series of inspections and functional checks was conducted at the time of installation to insure proper operation of the system. The following in- spection and adjustment procedures are recommended to maintain the system in its original operating condition. •...
  • Page 43 Chapter 5 Maintenance 1. Loosen the socket head cap screw on lever. 2. Rotate Delrin Brake (eccentric) to either increase or decrease gap between it and table frame. 3. Re-tighten socket head cap screw. 4. Re-check operation of Receptor Cabinet Lock Release Lever over entire travel of Receptor Cabinet.
  • Page 44 Chapter 5 Maintenance Figure 15. Replaceable Parts Location Diagram Figure 16. Replaceable Parts Location Diagram Model QT-730 Radiographic Table...
  • Page 45 Figure 17. Replaceable Parts Location Diagram ORDERING INFORMATION To order replacement parts for the Radiographic Table, contact the Service De- partment at: Quantum Medical Imaging, LLC 2905 Veterans Memorial Highway Ronkonkoma, New York 11779 USA Phone: (631) 587-5800 Fax: (631) 567-5074 e-mail: info@qmiteam.com...
  • Page 46 Chapter 5 Maintenance THIS PAGE INTENTIONALLY LEFT BLANK Model QT-730 Radiographic Table...