Summary of Contents for Quantum QW-400 Series

  • Page 1 Model QW-400 Series Vertical Wall Frame Installation and Operation Manual Manual Part No. DC30-001 Revision B...
  • Page 2 This manual is copyrighted and all rights are reserved. No portion of this document may be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine readable form without prior consent in writing from Quantum Medical Imaging, LLC.
  • Page 3 Revision History REVISION HISTORY REVISION DATE TYPE OF MODIFICATION 11/9/00 Initial Release. 2/12/01 Added UL Mark LIST OF EFFECTIVE PAGES Page Page Page Number Number Number i - x 1 - 30 Model QW-400 Vertical Wall Frame...
  • Page 4 Revision History THIS PAGE INTENTIONALLY LEFT BLANK Model QW-400 Vertical Wall Frame...
  • Page 5: Table Of Contents

    Table of Contents Table of Contents Section 1, Introduction Section 2, Specifications Section 3, Assembly & Installation Section 4, Operation Section 5, Maintenance Model QW-400 Vertical Wall Frame...
  • Page 6 Table of Contents THIS PAGE INTENTIONALLY LEFT BLANK Model QW-400 Vertical Wall Frame...
  • Page 7 Safety Notices WARNING Quantum Medical Imaging, LLC disclaims all responsibility from any in- jury resulting from improper application of this equipment. This equipment is sold to be used exclusively under the prescribed direc- tion of a person who is licensed by law to operate equipment of this na- ture.
  • Page 8 Safety Notices REGULATORY COMPLIANCE This certified Quantum Medical Imaging, LLC medical device has been designed, manufactured, and calibrated to comply with governing Federal Regulations 21 CFR Subchapter J and the performance standards attendant thereto. Upon installation, all certified products require the filing of Form FD-2579 "Report of Assembly of a Diagnostic X-Ray System"...
  • Page 9 Warranty Information WARRANTY STATEMENT Quantum Medical Imaging, LLC (herein known as “QMI”) warrants to buyer that any new product manufactured by QMI will be free from defects in material and manufactur- ing and conform substantially to applicable specifications in effect on the date of ship- ment when subjected to normal, proper and intended usage by properly trained person- nel.
  • Page 10 2) Failure of Buyer/Dealer to provide the proper incoming power required to sup- port the equipment in accordance with the recommendation of QMI. 3) Any modification of product performed by a party other than Quantum Medical Imaging. 4) Combining incompatible products.
  • Page 11 B) By making available any necessary repaired or replacement parts or as- semblies. Quantum Medical Imaging shall have the option to furnish either new or ex- change replacement parts or assemblies. All returned parts shall become the property of Quantum Medical Imaging.
  • Page 12 Warranty Information THIS PAGE INTENTIONALLY LEFT BLANK Model QW-400 Vertical Wall Frame...
  • Page 13: Section 1, Introduction

    Chapter INTRODUCTION...
  • Page 15 See Figure 1. The Model QW-400 Vertical Wall Frame contains: 1 Front Cover (phenolic) 2 Hand Control 3 Cassette Tray Handle 4 Receptor Cabinet 5 Compliance Label 6 Legs Figure 1. Vertical Wall Frame, Model QW-400 Series Model QW-400 Vertical Wall Frame...
  • Page 16 Chapter 1 Introduction THIS PAGE INTENTIONALLY LEFT BLANK Model QW-400 Vertical Wall Frame...
  • Page 17: Section 2, Specifications

    Chapter SPECIFICATIONS...
  • Page 19 Chapter 2 Specifications PHYSICAL SPECIFICATIONS The following are physical specifications for the Vertical Wall Frame: Frame Dimensions Height (total): 85.0 inches (2159.0 mm) • Height (excluding legs): 78.0 inches (1981.2 mm) • Width: 26.5 inches (673.1 mm) • Depth: 6.59 inches (167.4 mm) •...
  • Page 20 -30.5 to +3048 meters relative • to sea level COMPATIBILITY STATEMENT The Quantum Medical Imaging, LLC Vertical Wall Frame is compatible with all Quantum Medical Imaging, LLC manufactured tube stands and high-voltage x- ray generators. Model QW-400 Vertical Wall Frame...
  • Page 21: Section 3, Assembly & Installation

    Chapter ASSEMBLY & INSTALLATION...
  • Page 23 If any damaged parts are found, notify the shipping or freight company immediately (the manufacturer is relieved of any responsibility for damage during shipment after unit is picked up by the carrier). Should there be a shortage of parts, notify Quantum Medical Imaging’s Service Department. Model QW-400 Vertical Wall Frame...
  • Page 24 Chapter 3 Assembly & Installation ASSEMBLY INSTRUCTIONS To assemble the Vertical Wall Frame, refer to Figures 2 through 4. 1. Lift off the fiber-resin (phenolic) Front Cover from the Wall Frame. 2. Typically the Receptor Cabinet is pre-installed into the Wall Frame at the factory.
  • Page 25 Chapter 3 Assembly & Installation The slotted mounting holes in the Bucky Bearing Brackets are pro- vided to adjust tension on bearings (wheels). When adjusted prop- erly, the wheels on all four brackets should rotate throughout the entire travel distance of the Receptor Cabinet. g.
  • Page 26 Chapter 3 Assembly & Installation 4. Connect the black coil cable wires to Terminal Board TB1 terminals 2 and 3 as shown in Figure 3. 5. On systems configured for right-hand film loading, tie-wrap coil cord cable as shown in Figure 4. 6.
  • Page 27 Chapter 3 Assembly & Installation 4. Connect the black coil cable wires to Terminal Board TB1 terminals 2 and 3 as shown in Figure 3. 5. On systems configured for right-hand film loading, tie-wrap coil cord cable as shown in Figure 4. 6.
  • Page 28 Chapter 3 Assembly & Installation COIL CORD TIE- WRAPPED TO FRAME COIL CORD TIE- WRAPPED TO COUNTER- WEIGHT CABLE Figure 4. Coil Cord Cable Routing (Right Hand Load Systems) Model QW-400 Vertical Wall Frame...
  • Page 29 Chapter 3 Assembly & Installation COIL CORD TIE- WRAPPED TO FRAME Figure 5. Coil Cord Cable Routing (Left hand Load Systems) INSTALLATION INSTRUCTIONS 1. Stand the Vertical Wall Frame against wall in proper position. Level Vertical Wall Frame front-to-back and left-to-right using bubble level (use shims to level left-to-right, as necessary).
  • Page 30 Chapter 3 Assembly & Installation 5. Secure the Wall Frame to the floor through the Floor Mounting Brack- ets using the appropriate hardware for floor construction (must be ca- pable of supporting 100 lbs. pull-load) as shown in Figure 6. MOUNTING BRACKET HOLES (2X)
  • Page 31 Chapter 3 Assembly & Installation 8. Connect red and black wires from a double (or reinforced) insulated 24 VDC power source (must meet construction/performance criteria per UL 2601-1) to Terminal Board TB1 terminals 1 and 2, respectively (see Fig- ure 3). Use cable ties, as required, to manage cable. 9.
  • Page 32: Section 4, Operation

    Chapter OPERATION...
  • Page 34 Chapter 4 Operation VERTICAL WALL FRAME OPERATION Operation of the Vertical Wall Frame involves moving the Receptor Cabinet (film holder) vertically (i.e., up or down). This is accomplished by depressing the Re- ceptor Cabinet Lock Release Button (see Figure 8), located on the control handle attached to the Receptor Cabinet, and then moving the cabinet to the desired vertical position.
  • Page 35 Chapter 4 Operation CASSETTE TRAY OPERATION The Vertical Wall Frame is equipped with either a Midwest or Poersch cassette tray, depending on the system ordered. The following paragraphs describe the operating instructions for each. Additional information is contained in the cas- sette tray manufacturer’s documentation, which is shipped with the wall frame.
  • Page 36 Chapter 4 Operation 8. Push tray into Receptor Cabinet. The cassette is now in exposure posi- tion. Loading Cassette Tray (Poersch Type) To load a film cassette into a “Poersch” type cassette tray, proceed as fol- lows: 1. Pull cassette tray from Receptor Cabinet using tray handle (see Figure 10).
  • Page 37 Chapter 4 Operation THIS PAGE INTENTIONALLY LEFT BLANK Model QW-400 Vertical Wall Frame...
  • Page 38: Section 5, Maintenance

    Chapter MAINTENANCE...
  • Page 40 Chapter 5 Maintenance OVERVIEW The Vertical Wall Frame will function reliably when maintained according to the in- structions provided in this chapter. WARNING! Only properly trained service personnel should se WARNING! Only properly trained service personnel should se WARNING! Only properly trained service personnel should ser- vice or maintain this equipment.
  • Page 41 Chapter 5 Maintenance A complete series of inspections and functional checks was conducted at the time of installation to insure proper operation of the system. The following in- spection and adjustment procedures are recommended to maintain the system in its original operating condition. Check for evidence of loose hardware or loose wires.
  • Page 42 Chapter 5 Maintenance A complete series of inspections and functional checks was conducted at the time of installation to insure proper operation of the system. The following in- spection and adjustment procedures are recommended to maintain the system in its original operating condition. Check for evidence of loose hardware or loose wires.
  • Page 43 Figure 11. Model QW-400 Vertical Wall Frame Parts Location Diagram ORDERING INFORMATION To order replacement parts for the Vertical Wall Frame, contact the Service De- partment at: Quantum Medical Imaging, LLC 2905 Veterans Memorial Highway Ronkonkoma, New York 11779 USA Phone: (631) 587-5800...
  • Page 44 Chapter 5 Maintenance Figure 12. Model QW-400 Vertical Wall Frame Parts Location Diagram Model QW-400 Vertical Wall Frame...