Download Print this page

Rotary GLP99SM Operating Instructions Manual

Scissor lift free wheels gemini low profile

Advertisement

Quick Links

SCISSOR LIFT FREE WHEELS
GEMINI LOW PROFILE
OPERATING
INSTRUCTIONS
GLP99SM-GLP99SM/P

Advertisement

loading
Need help?

Need help?

Do you have a question about the GLP99SM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rotary GLP99SM

  • Page 1 SCISSOR LIFT FREE WHEELS GEMINI LOW PROFILE OPERATING INSTRUCTIONS GLP99SM-GLP99SM/P...
  • Page 2 DECLARES ON ONE’S OWN RESPONSIBILITY THAT THE EQUIPMENT SPECIFIED BELOW: TYPE OF EQUIPMENTS: SCISSOR LIFT FREE WHEELS MODEL: GLP99SM •; GLP99SM/P •; PART NUMBER: ..........TO WHICH THIS DECLARATION IS RELATED, CONFORMS WITH THE FOLLOWING EUROPEAN DIRECTIVES: 98/37/CEE - 73/23CEE- 93/68 CEE - 89/336 IT ALSO DECLARES THAT THE FOLLOWING EUROPEAN RULES HAVE BEEN RESPECTED : EN 292.1- EN 292.2- EN294-EN 349- EN 1050- EN 60204-1.
  • Page 3 This manual is considered to be a permanent part of the lift and must be kept in an easily accessible place so that the operator can find it and refer to it .A particularly careful reading of chapter “3” on safety is recommended. All versions of “GLP99SM-GLP99SM/P” have been designed and built as required by: EUROPEAN RECOMMENDATIONS: EEC 98/37/CEE, 73/23/CEE, 93/68/CEE, 89/336/CEE.
  • Page 4 CHAPTER 2- MACHINE DESCRIPTION MODELS-TECHNICAL SPECIFICATIONS “GLP99SM” models are double scissor, low profile, (only 12 cm.), and fixed (that is anchored to the ground) car lifts and can be delivered in both surface or recessed versions. They have been designed and built for car, van lifting and placing operations.
  • Page 5 “1” position: the lift is powered. “GLP99SM-GLP99SMP” double scissor car lifts are able to lift vehicles and van whose weight is no more than 3000 kg. The height is adjustable so that it can be easily and safely operated as needed. All version are equipped with extension platforms so vehicles with a longer “wheel base”...
  • Page 6 WARNING: “GLP99SM-GLP99SMP” car lift has been designed and built to lift and place cars in closed areas. Any other use is forbidden, and particularly, the following operations cannot be performed: -VARNISHING - LIFTING OF PEOPLE OR SCAFFOLDING - SQUASHING PRESS - CAR JACK OR WHEEL REPLACEMENT.
  • Page 7 SAFETY DEVICES ANTI-SHEARING SAFETY.The lift is provided with a device that stops it automatically for a few seconds at approximately 30 cm from the floor, when the lift is lowered from this point the device produces a warning acoustical signal. PHOTOELECTRIC SWITCH (PHOTO CELL).
  • Page 8 3) ELECTRIC CONNECTIONS Connect the lift cables numbered (see diagram) to the relative connector placed within the electric card of the power unit. WIRING CONNECTIONS POSITION N. CODE DESCRIPTION 06-0302 Lifting limit switch 06-6607 Photoelectric cell 06-0302 P2 platform self levelling 06-0302 P1 platform self levelling 06-0302...
  • Page 9 WIRING DIAGRAMS...
  • Page 10 WIRING DIAGRAM...
  • Page 11 WIRING DIAGRAM...
  • Page 12 ELECTRIC CARD JP1/17 CONNECTORS K1/17 RELAIS D1/37 DIODS R1/44 RESISTORS SPRI BLEEPER RESET TIMER BUTTON TIMER REGULATOR TIMER MICROCHIP BLEEPER MICROCHIP C1/24 CAPACITOR TR1/5 TRANSISTORS IC 1-2-3-5 VOLTAGE STABILIZER QUARTZ REGULATOR...
  • Page 13 4) HYDRAULIC CONNECTIONS 04-3003 P1 DELIVERY (A) 04-3006 CONNECTION-P2 DELIVERY (E) 04-3007 DISCHARGE (B) 04-3001 LEVELLING-P2 DELIVERY (C) 04-3004 PIPE CONNECTION (H) P1 HYDRAULIC PLAN PARACHUTE VALVE 3,5 L. PUMP LEVELLING ELECTRO VALVE (EL) THREE PHASE MOTOR 4 HP LOWERING ELECTRO VALVE (EO) SUCTION FILTER FLOW REGULATOR VALVE HAND PUMP...
  • Page 14 Photoelectric cell INFRA 18-12M/pnp NO24V Electric cable 2 wires various Electric 3 wires various General switch Sprecher Schuh L3-32-1753 16A Touchpad TASTITALIA D.ROTARY LIFT Three pole base WEBER 25A-380V Fuse WEBER Various Contactor Sprecher Schuh Transformer 70VA Electric card ROTARY LIFT D.ROTARY LIFT...
  • Page 15 6) LIFT FIXING After making electric and hydraulic connections, make sure they are properly connected. Now fix the lift to the floor, using the bases as templates, drill a hole into the floor a 18 mm.Ø bit must be used up to a depth of about 150 mm., clean the holes, place the proper inserts with light hammer blows and finally tighten the bolts.
  • Page 16 Lift does not operated Failure in the electric system Check connections electric components for proper conditions. Lowering operation cannot be performed Damaged lowering solenoid valve Check the failure of the electrovalve Lowering is too slow Flow regulator valve for lowering control Contact service dept.
  • Page 17 • Rubber support. • Rubber pads T4B. Standard colours are: RAL 5015- RAL 3002. If requested, it’s possible to have special colours and cold galvanizing CHAPTER 9-SPARE PARTS Respect all the safety precaution indicated on chapter “3” and “6” when making the substitution of the spare parts and the repair intervals.
  • Page 19 FIG.3 LEVERS AND PISTON FIG. 4 PLATFORM...
  • Page 20 FIG. 5 CONTROL BOX...
  • Page 21 FIG. 6 ELECTRIC COMPONENTS FIG. 7 SAFETY ELEMENTS FIG. 8 RAMPS...
  • Page 22 FIG. 1 BASE CODE DESCRIPTION QUANTITY 01-2224 P1-P2 BASE 01-2252 CLAMP 03-3082 M8X24 TE SCREW 01L2266Z CLAMP (ONLY ON FLOOR9 01L2265Z CLAMP (ONLY ON FLOOR) 01L2264G FOOTGUARD (ONLY ON FLOOR) FIG. 2 ARMS 01-2263 LOWER INSIDE BOOM 01-2267 LOWER OUTSIDE BOOM 01-2271 LEFT UPPER OUTSIDE BOOM 01-2270...
  • Page 23 FIG. 5 CONTROL BOX CODE DESCRIPTION QUANTITY 06-6012 FINISHING ELEMENTS 06-6055 MAIN SWITCH 01-1618 CABINET 06-1003 TOUCHPAD 01-1622 DOOR 06-6126 THREE PHASE MOTOR 04-4587 PUMP 04-4024 OIL CAP 01-1610 OIL TANK 04-4600 HAND PUMP/ELECTROVALVE BLOCK 06-0335 FULL ELECTRIC CARD 01-1611 TANK COVER 01-1624 CONSOLLE...
  • Page 24 SCISSOR LIFT FREE WHEELS LOW PROFILE MAINTENANCE BOOK LP99/SM-LP99/SMP INITIAL TEST DESCRIPTION TEST Notes Floor consistency check Safety distances check (from walls, columns, ceiling, other machines etc.) Power supply line check. Lift levelling check. Lift working check. Hydraulic safeties working check. Electric safeties working check.
  • Page 25 RECURRING OR OCCASIONAL VISIT DESCRIPTION OF TEST Notes Lift maintenance and cleaning check. Hydraulic safeties working check. Electric safeties working check. Oil level check. Rollers slides fastening. Movable parts fastening. High pressure flexible pipes check. Hydraulic failure check. Lift levelling check. Loaded lift check.
  • Page 26 TESTS TO BE MADE BY THE USER TESTS DURING USE Levelling check. Hydraulic failure check. Pneumatic failure check. Safety devices working check. MONTLY TESTS Lift through cleaning. Rollers slides check. Cylinders air bleeding (if necessary). HALF-YEARLY TESTS Oil level check. High pressure flexible pipes check.
  • Page 27 REPAIR FAILURE ACTION Date Stamp and signature REPAIR FAILURE ACTION Date Stamp and signature October 2000 BY THE GRAPHIC DEPARTEMENT (A.R:) ROTARY LIFT EUROPE S.r.l. Via Tiburtina Km209+800, 65025 Manoppello Scalo – PESCARA - ITALY. Tel. 085/8569058-Fax 085/8569059...

This manual is also suitable for: