Memory Board - Videx ESVK/6788 Series Installation Handbook

“2 wire” bus one way, two way videokit
Hide thumbs Also See for ESVK/6788 Series:
Table of Contents

Advertisement

ESVK/6788 Series "2 wire Bus" videokit
Art. 6788
7" colour display videophone
EXTENSION NO – SW3.2..3
If the intercommunication between apartments is enabled (switch 1 of SW3 = ON)
leave these two switches in default position (both to OFF). Otherwise, if the in-
tercommunication is between the same apartment (switch 1 of SW3 = OFF), set
the extension addresses starting always from 1. During the external call, all video
monitors in the same flat will ring but the video will be shown only from the vide-
ophone with extension address 1..
SLAVE MODE - SW3.4
This set up concerns the answering mode of the video monitor when there is more than one unit (max 4) in the same
apartment. OFF (default) = during a call, only the video monitor with extension 1 (master) will show the video. ON =
the video monitor will be switched on independently of the extension address: in this case the video monitor must be
supplied locally using a power supply Art. 2321 or Art. AMR-12, see notes on 12M and VA on "Connection Terminals
Signals" table (the local power supply is required for each black & white slave videophone or starting from the third slave
videophone when they are all colour videophones).
If you set for one slave videophone, you must set ON the same switch also for the relevant master videophone..
NOTE: WHEN USING CST2310 CONCIERGE
To enable calling to the concierge and receiving
calls from the concierge; on the master device (SW3
Dip 2&3 OFF), set dip switch 1 of SW2 to OFF and
also dip switch 4 of SW3 to ON. Intercommunication
is between devices in the same apartment.
CONNECTION TERMINALS SIGNALS
BUS1 Bus input
BUS2 Bus input
GND
Ground
+12Vdc power supply input (Art. 323/12 or Art. AMR2-
12) for version with Memory Board option or auxiliary
12M
power supply input (to be used when two or more
slave monitors are ringing together with the switch 4
of SW3 is set to ON)
GND
Ground
+30Vdc power supply input (Art.  2321) to be used
VA
when two or more slave monitors are ringing togeth-
er with the switch 4 of SW3 set to ON
Dry contact. Internally linked to NO
C
when the
button is pressed.
Dry contact. Internally linked to C when
NO
the
button is pressed.
–DOL Auxiliary LED power supply input (ground)
+DOL Auxiliary LED power supply input (+12Vdc)
Ground output for use in combination with AL & LB
GND A
active low inputs
LB
Local bell input (active low)
AL
Alarm input (not implemented yet)
ESVK/6788 Series - Installation handbook
TECHNICAL SPECIFICATIONS
Housing and mounting: 6700 Series - Surface
SW3
Push buttons:
ON
Programming:
1
2
3
4
Controls:
Power consumption:
Working voltage:

MEMORY BOARD

This device is also available in the version with
memory board (Art. 6788/VM).
If you have that version, please refer to the
Max 35Vdc,
"6200, 6300, 6400 and 6700 Series Memory
50mA
Board" user manual for installation and use.
The manual is available for download:
click/tap or scan the QR code.
- 25 -
ON
2
3
OFF
OFF 1 (default, master)
1
2 3
4
ON
OFF 2 (slave)
SW3.2..3
OFF
ON 3 (slave)
ON
ON 4 (slave)
4
Through buttons and dip-switches
Speech volume
Call tone volume
Brightness
Colour intensity
Contrast
Stand-by
(dip-switch 8 OFF): 1/3mA
Stand-by
(dip-switch 8 ON): 80mA
Operating:
Peak:
Supplied by the BUS line
66550029-EN - V6.6 - 31/08/22
EXTENSION NO.
ON
1 2 3
4
SW3.4
200mA
400mA

Advertisement

Table of Contents
loading

This manual is also suitable for:

EsvkEsvkxEsvkc6788Esvkx 6788Esvkc 6788

Table of Contents