Table 6. Group 6 airflow settings (continued)
Menu Item
VS Blower On Delay — Comp Htg
Non VS Blower On Delay — Comp Htg
VS Blower Off Delay — Comp Htg
Non VS Blower Off Delay — Comp Htg
Hydronic Heat Blower On Delay
Hydronic Heat Blower Off Delay
Compressor 1st Stage Air Flow% — Comp Clg
Compressor 1st Stage Air Flow % — Comp Clg
Compressor 1st stage Air Flow% — Comp Htg
Compressor 1st stage Air Flow% — Comp Htg
(a)
Variable speed applies only to supported Trane residential equipment
Table 7. Group 7 lockout (Must have OAT enabled to use either Internet Weather or a sensor wired to ODT input for
Group 7 to appear)
Menu Item
Auxiliary Heat Lockout
Auxiliary Heat Lockout Setting
Compressor Lockout
Compressor Lockout Setting
Defrost Heater Balance Point (W1)
BAS-SVX078E-EN
Options [Default]
[No Delay],
Enhanced Mode
7.5 Minutes @ 80%
4 Minutes @ 80%
1 Minute @ 50%
30 Seconds
[No Delay],
15 Seconds
30 Seconds
[No Delay],
1.5 Minutes @ 100%
45 Seconds @ 100%
30 Seconds @ 100%
1.5 Minutes @ 50%
3 Minutes @ 50%
30 Seconds @ 35%
[No Delay],
30 Seconds
60 Seconds
90 Seconds
[No Delay],
30 Seconds
60 Seconds
[No Delay],
30 Seconds
60 Seconds
90 Seconds
35% to 60%, [50%]
55% to [80%]
35% to 60% [50%]
55% to [80%]
Options [Default]
[Disable], Enable
32°F to 70°F, [45°F]
[Disable], Enable
5°F to 70°F, [30°F]
[Disable], Enable
System Setup
Description
Select the blower on delay for compressor heating
operation.
Enhanced Mode is a tiered Blower on Delay for
variable speed blowers only (1 minute at 50%, 7.5
minutes at 80%, then 100%.)
(a)
Select the blower on delay for compressor heating
operation.
Select the blower off delay for compressor heating
operation.
Select the blower off delay for compressor heating
operation.
Select the blower on delay for hydronic heating
operation.
Select the blower off delay for hydronic heating
operation.
Select the 1st stage air flow for a two stage/two
compressor unit in cooling mode.
Select the 1st stage air flow for a two stage/single
compressor unit in cooling mode
Select the 1st stage air flow for a two stage/two
compressor unit in heating mode
Select the 1st stage air flow for a two stage/single
compressor unit in heating mode.
Description
Enable auxiliary heat lockout (10°F minimum
separation when enabling auxiliary heat lockout
and compressor heat lockout)
Select an outdoor temperature to prevent auxiliary
heat above the selected outdoor temperature.
Enable compressor heat lockout (10°F minimum
separation when enabling auxiliary heat lockout
and compressor heat lockout)
Select an outdoor temperature to prevent
compressor heating below the selected outdoor
temperature
Enable defrost heater balance point for W1 and W2
(only applicable when indoor heat is electric or
hydronic)
25