System Setup; Power-Up Sequence; Installation Wizard Overview; Installer Setup Screens - Trane Pivot BAYSTAT814 Series Installation, Operation And Maintenance Manual

Smart thermostat
Table of Contents

Advertisement

System Setup

Power-up Sequence

The unit initiates a 90 to 120 second power-up sequence. During the sequence, the Screen Calibration
option is made available for five (5) seconds. However, Screen Calibration is available for five (5)
minutes if the screen has never been calibrated and following a Restore Factory Defaults command.
Note: The Pivot thermostat comes factory calibrated.
If the unit screen is not pressed within 5 minutes, the unit defaults to previously stored calibration
settings. The unit can be re-calibrated any time by rebooting the unit.
Note: Temperature display may be inaccurate until the unit acclimates to ambient room temperature.

Installation Wizard Overview

The Installation Wizard displays when:
The wizard setup guides the installer through:

Installer Setup Screens

Individual parameters are configured and edited from the Installer Setup screens. Use the up/down
arrows to scroll through groups of settings. To change a setting within a specific group, press Edit and
then press Next to navigate to the desired setting. Press Save to retain changes or Exit to discard
changes.
18
This may take up to one (1) hour.
The unit is initially powered on.
The Restore Factory Defaults function is invoked.
Selected from Service Menu (Home > Menu > Service > Technician Access (press for 5 seconds)
>Proceed > Service Menu > Installation Wizard or Installer Setup).
Note: A PIN access code may have been previously set up on the thermostat by the building owner,
which may restrict access to the Menu screen and/or Service screen. If PIN access has been
set up, the thermostat will display a notification when attempting to access the Menu or
Service screen. In this case, the technician must obtain the PIN access code from the
building owner or request to have the thermostat unlocked.
Time/Date
Set the current time/date and set Daylight Saving Time to On/Off.
Installer Setup
Configure the basic equipment components installed and customize how the unit operates.
Service Reminders
Various service reminders can be enabled based on the system configuration, such as, System,
Filter, Ventilation , UV Light, and Humidifier. The frequency can be selected based on calendar
or runtime days.
Contractor Identification Code
The contractor identification code is used to populate the contractor contact information and
associate the unit with a Pivot contractor portal account. The contractors primary telephone
number is entered to activate this feature.
Note: Only units connected to the Internet will auto-populate the contractor information.
BAS-SVX078E-EN