Advertisement

Quick Links

16644-R
STOP!
STOP!
Call Us First!
DO NOT RETURN TO STORE.
For immediate help with assembly or product information
call our toll free number:
1-800-577-9663
or email:
customerservice@backyardproductsllc.com
Our staff is ready to provide assistance
April through October M-F 8:00 AM to 4:30 PM EST
Saturday 8:30 AM to 4:30 PM EST
November through March M - F 8:00 AM to 5:00 PM EST

Advertisement

Table of Contents
loading

Summary of Contents for Backyard Products Heartland MANSFIELD GABLE

  • Page 1 16644-R STOP! STOP! Call Us First! DO NOT RETURN TO STORE. For immediate help with assembly or product information call our toll free number: 1-800-577-9663 or email: customerservice@backyardproductsllc.com Our staff is ready to provide assistance April through October M-F 8:00 AM to 4:30 PM EST Saturday 8:30 AM to 4:30 PM EST November through March M - F 8:00 AM to 5:00 PM EST...
  • Page 2 (This page intentionally left blank.)
  • Page 3: Before You Begin

    16644-R 10-05-2017 A Backyard Products Company MANSFIELD GABLE 10' x 12' (305 x 366 cm) ACTUAL FLOOR SIZE IS 120 x 144" (304,8 x 365,8 cm) KEEP THIS MANUAL FOR FUTURE REFERENCE IMPORTAN T ! READ INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING ASSEMBLY.
  • Page 4 TOOLS Required Optional Phillips ❑ Tool Belt/ ❑ Utility Knife ❑ Screwdriver Nail Pouch Shingle Blades ❑ Drill / Driver ❑ Caulk Gun ❑ 1/8" Drill Bit ❑ Tin Snips ❑ 1/4" Drill Bit ❑ (for drip edge) 5/16" Drill Bit ❑...
  • Page 5: Additional Materials

    ADDITIONAL MATERIALS FOUNDATION OR FLOOR MATERIALS • This shed does not include any floor or leveling materials. • See the FLOOR LEVELING section on page 8 for recommended methods and suggested materials to properly level your floor, as this will vary depending on your specific site. WOOD FLOOR FRAME MATERIAL REQUIRED: Use only wood treated for ground contact and fasteners approved for use with treated wood.
  • Page 6: Parts List

    PARTS IDENTIFICATION AND SIZES Part identification WOOD SIZE CONVERSION CHART letters are stamped on some parts. Treated lumber is stamped: Nominal Board Size Actual Size 2" x 4"....1-1/2" x 3-1/2" (3,8 x 8,9 cm) 1" x 4"....3/4" x 3-1/2" (1,9 x 8,9 cm) 2"...
  • Page 7 PARTS LIST continued... 2 x 3 x10-1/8" (5,1 x 7,6 x 25,7 cm) 2 x 4 x 24" (5,1 x 10,2 x 61 cm) 1 x 4 x 23-7/8" (2,5 x 10,2 x 60,6 cm) 1 x 4 x 96" (2,5 x 10,2 x 243,8 cm) 2 x 4 x 96"...
  • Page 8 WORK BENCH PARTS 2 x 3 x19" (5,1 x 7,6 x 48,3 cm) 1 x 4 x 23-7/8" (2,5 x 10,2 x 60,6 cm) 3/8 x 14-1/4 x 22-1/4" (1 x 36,2 x 56,5 cm) 1 x 4 x 96" (2,5 x 10,2 x 243,8 cm) 7/16 x 20-3/4 x 92-1/2"...
  • Page 9 FLOOR LEVELING OPTIONS There are multiple ways to level your floor frame. Our recommended leveling method is shown below. Leveling materials are not included in this kit. PREFERRED METHOD - 4x4 TREATED RUNNERS • 3" Screws angled into 4x4. • (2) at each point frame •...
  • Page 10 CONCRETE FOUNDATION Your kit contains all materials to construct a wooden floor. If you choose to install your kit on a concrete slab refer to the diagram below. Treated Sill Plate Caulk between sill plate and concrete. 3-1/2" (8,9 cm) 4"...
  • Page 11 IMPORTANT! Check the floor frame is level after installing floor panels. Re-level if needed. • The floor should be used as a stable work surface for wall construction. • Organize your assembly procedure during the build process HINT: to avoid over-handling of the walls. EAVE SIDE WALL GABLE END WALL EAVE SIDE WALL GABLE END WALL...
  • Page 12: Parts Required

    RAFTER ASSEMBLY PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 5-7/8" (5,1 x 10,2 x 14,9 cm) It is very important to assemble your rafters using the following method for an even and flat roof. You will build a rafter jig using the floor and three PVA parts as shown. ¸ BEGIN Secure one PVA flush to the floor deck using two 3" screws. Measure over 120-3/4"...
  • Page 13 RAFTER ASSEMBLY PARTS REQUIRED: x 10 x 70 2" (5,1 cm) 1-5/8" (4,1 cm) OSB OR WOOD GRAIN 6 x 24" (15,2 x 61 cm) 2 x 4 x 75-1/4" (5,1 x 10,2 x 191,1 cm) ¸ BEGIN Place two rafters ECN into the jig as shown. Keep ECN firm against outside PVA's as shown (Fig.A) and push rafters tight to the middle PVA.
  • Page 14: Front Wall

    FRONT WALL PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 22-1/2" (5,1 x 10,2 x 57,1 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 2 x 4 x 8-1/2" (5,1 x 10,2 x 21,6 cm) 2 x 4 x 67"...
  • Page 15 FRONT WALL PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 12-1/2" (5,1 x 10,2 x 31,8 cm) 2 x 4 x 67" (5,1 x 10,2 x 170,2 cm) 2 x 4 x 68-1/2" (5 x 10,2 x 174 cm) 2 x 4 x 80"...
  • Page 16 FRONT WALL PARTS REQUIRED: 2" (5,1 cm) 3/4" GAUGE 48 x 84" BLOCK (121,9 x 213,4 cm) Ensure your wall frame is square by installing one panel and squaring frame. Place 48 x 84" panel onto wall frame flush to top of frame with primed side up as shown. Use the gauge block to mark the 3/4"...
  • Page 17 FRONT WALL PARTS REQUIRED: 2" (5,1 cm) 48 x 84" 48 x 84" (121,9 x 213,4 cm) (121,9 x 213,4 cm) x1 LEFT 1 RIGHT For squareness maintain flush and 3/4" measurement along panel edges. Place left 48" x 84" panel on frame as shown with primed side facing up. Flush 3/4"...
  • Page 18 BACK WALL PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 2 x 4 x 80" (5,1 x 10,2 x 203,2 cm) 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) HINT: BEGIN For easier nailing...
  • Page 19 BACK WALL PANELS PARTS REQUIRED: 2" (5,1 cm) 48 x 84" (121,9 x 213,4 cm) 3/4" GAUGE BLOCK Ensure your wall frame is square by installing one panel and squaring frame. Place 48 x 84" panel onto wall frame flush to top of frame with primed side up as shown. Use the gauge block to mark the 3/4"...
  • Page 20 BACK WALL PANELS PARTS REQUIRED: 2" (5,1 cm) 3/4" GAUGE BLOCK 48 x 84" (121,9 x 213,4 cm) For squareness maintain flush and 3/4" measurement along panel edges. Place center 48" x 84" panel on frame as shown with primed side facing up. Flush 3/4" (1,9 cm) Nail using 2" nails 6" apart on edges and 12"...
  • Page 21 GABLE WALL PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 80" (5 x 10,2 x 203,2 cm) 2 x 4 x 68-1/2" (5,1 x 10,2 x 174 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) ASSEMBLE IDENTICAL GABLE WALLS.
  • Page 22 GABLE WALL PARTS REQUIRED: 2" (5,1 cm) 3/4" GAUGE 48 x 84" BLOCK (122 x 213,4 cm) Place 48" x 84" panel with primed side up onto frame flush at top and with a 3/4" gap on right side. Maintain 3/4" measurement along edge. Secure panel to frame using 2" (5,1 cm) nails 6" (15,2 cm) apart along edges. Flush BEGIN HERE 3-1/2...
  • Page 23 GABLE WALL PARTS REQUIRED: 2" (5,1 cm) 23-7/8 x 84" 48 x 84" (60,6 x 213,4 cm) (122 x 213,4 cm) Place 23-7/8" x 84" primed side up and flush with installed 48" x 84" panel edge. Ensure panel is flush at top. Secure using 2" (5,1 cm) nails 6" (15,2 cm) apart on edges. Place 48" x 84"...
  • Page 24: Back Wall Installation

    BACK WALL INSTALLATION PARTS REQUIRED (TEMPORARY): 3" (7,6 cm) 1-1/2 x 2-1/2 x 69" (3,8 x 6,3 x 175,3 cm) 3" (7,6 cm) 2" (5,1 cm) BEGIN Stand right back wall on floor. Center right back wall assembly on the 144" (365,8 cm) floor dimension. Use OO as a temporary brace.
  • Page 25 GABLE WALL INSTALLATION PARTS REQUIRED: 3" (7,6 cm) 1-1/2" (3,8 cm) 2" (5,1 cm) 3" (7,6 cm) 2" (5,1 cm) 2" (3,8 cm) BEGIN Flush Screw Flush Stand gable wall on floor. STEP FIRST SCREW Fig. A It is important to secure the gable end wall 2"...
  • Page 26 FRONT WALL INSTALLATION PARTS REQUIRED: 3" (7,6 cm) 1-1/2 x 2-1/2 x 69" (3,8 x 6,3 x 175,3 cm) 2" (5,1 cm) 2" (5,1 cm) 1-1/2" (3,8 cm) BEGIN Stand front wall on floor. Center FRONT WALL assembly on the 144" (365,8 cm) floor dimension.
  • Page 27 FRONT WALL INSTALLATION PARTS REQUIRED: 3" (7,6 cm) 2" (5,1 cm) Nail lower edge of panels to floor frame using 2" nails 6" apart. Angle nail to hit floor frame (Fig. D). Secure front wall bottom plates to floor using 3" nails (Fig. D). 3"...
  • Page 28 GABLE WALL INSTALLATION PARTS REQUIRED: 3" (7,6 cm) 2" (5,1 cm) 2" (5,1 cm) 3" (7,6 cm) 1-1/2" (3,8 cm) BEGIN Remove Temporary Supports and stand gable wall on floor. It is important to secure the gable wall in the following order: Set gable wall on floor and secure using one 2"...
  • Page 29 GABLE WALL INSTALLATION PARTS REQUIRED: Nail lower edge of panels to floor using 2" nails 6" apart. Angle nail to hit floor frame (Fig. C). 2" (5,1 cm) Nails 6" (15,2 cm) Angle nail to hit floor frame. Fig. C 3" (7,6 cm) Screw Nail gable wall panels to eave wall studs Fig.
  • Page 30 GABLE PANELS PARTS REQUIRED: 1-1/2" (3,8 cm) 2 x 4 x 24" (5,1 x 10,2 x 61 cm) 2 x 3 x 75-1/4" (5,1 x 7,6 x 191,1 cm) TEMPORARY SUPPORT BEGIN You will build TWO assemblies. Orient RL and ECA on flat as shown. Place LEFT front gable panel as shown and secure using 1-1/2"...
  • Page 31 GABLE LADDERS PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 4-7/8" (5,1 x 10,2 x 12,4 cm) 2 x 3 x 75-1/4" (5,1 x 7,6 x 191,1 cm) BEGIN Orient parts as shown (Fig. A). You will build FOUR assemblies (Fig. B). Arrange, measure and mark locations of four CLA as shown place ECA on top.
  • Page 32 GABLE ASSEMBLIES PARTS REQUIRED: 3" (7,6 cm) 1-5/8" (4,1 cm) 2 x 4 x 5-7/8" x2 Gable Assemblies x2 Ladder Assemblies (5,1 x 10,2 x 14,9 cm) Orient gable and ladder assemblies as shown (Fig. E). You will build TWO complete assemblies. Ensure gable panels are flush at peak of ladder and flush along top edge of ladder assembly.
  • Page 33 GABLE UNITS PARTS REQUIRED: 3" (7,6 cm) 2" (5,1 cm) x2 Gable Units BEGIN Attach gable unit on gable wall top plate. It is important to secure the gable unit in the following order: Measure 1-1/2" down from top plate and mark at each side as shown. Set gable unit on top plate. Hold secure with one 2"...
  • Page 34 TRUSSES PARTS REQUIRED: 3" (7,6 cm) Preassembled Truss ¸ BEGIN Locate first truss on top plate, aligned over studs at each side and tight to side wall (Fig. A). Rest notch on top plate. Secure rafter to top plate with two 3" screws above notch and one 3" screw from under top plate (Fig. B, C). Place remaining rafters on top plate, aligned over studs as shown and secure with 3"...
  • Page 35 ROOF PANELS PARTS REQUIRED: x230 2" (5,1 cm) 3/4" GAUGE 7/16 x 27-1/4 x 32-5/8" BLOCK (1,1 x 69,2 x 82,9 cm) 7/16 x 32-5/8 x 48" 7/16 x 48 x 96" 7/16 x 27-1/4 x 48" (1,1 x 82,9 x 121,9 cm) (1,1 x 121,9 x 243,8 cm) (1,1 x 69,2 x 121,9 cm) Roof panels may cause serious injury until securely fastened.
  • Page 36 ROOF PANELS PARTS REQUIRED: Attach another 27-1/4" x 32-5/8" roof panel flush to bottom of the installed 48"x 96" panel and flush with the rafter ends (Fig. B). Secure panel with two 2" (5,1 cm) nails in the corners. Two Nails Flush 27-1/4" x 32-5/8" Flush Flush Fig.
  • Page 37 ROOF PANELS PARTS REQUIRED: Two Nails Place 27-1/4" x 48" upper roof panels centered and flush to lower panel. Ensure 3/4" measurement on the rafters (Fig. A). Secure the lower edge of roof Flush panels using two 2" nails in 3/4" corners as shown. (1,9 cm) Flush Gauge...
  • Page 38 ROOF PANELS PARTS REQUIRED: Secure roof panels using 2" nails 6" apart on edges and 12" apart inside panel. 6" 12" (15,2 cm) (30,5 cm) Repeat STEPS 1 - 8 to attach roof panels on the opposite side. FINISH You have finished installing your roof panels.
  • Page 39 GABLE END SOFFITS PARTS REQUIRED: 2" (5,1 cm) 3/8 x 7-7/8 x 73-5/16" (1 x 20 x 186,2 cm) Ensure soffit boards are flush at seam (Fig. B) and flush at peak (Fig. D). BEGIN Position right 73-5/16" overhang board Primed Side Down flush to front wall (Fig A) and gable panel seam (Fig B). Secure using twelve 2" finish nails. Fig.
  • Page 40 EAVE SIDE SOFFITS PARTS REQUIRED: 2" (5,1 cm) 3/8 x 5-7/8 x 72-3/4" (1 x 14,9 x 184,8 cm) Ensure soffit boards are flush at rafter ends (Fig. B) and flush at seams. BEGIN Position 72-3/4" soffit boards primed side down flush to gable soffits and rafter ends (Fig A). Toenail at center seam (Fig. C). Secure using eight 2" finish nails, two in each rafter. Fig.
  • Page 41 GABLE FASCIA PARTS REQUIRED: 2" (5,1 cm) Painted Red 3/8 x 4-3/4 x 75-7/8" (1 x 12,1 x 192,7 cm) Painted Green 3/8 x 4-3/4 x 75-7/8" (1 x 12,1 x 192,7 cm) BEGIN Position fascia with primed side out and flush to peak and roof panels as shown (Fig. A, Fig B). Secure using 2"...
  • Page 42 EAVE SIDE FASCIA PARTS REQUIRED: 2" (5,1 cm) 3/8 x 4-3/4 x 80-5/8" (1 x 12,1 x 204,8 cm) BEGIN Position two 4-3/4" x 80-5/8" fascia boards with primed side out, flush with roof panels and gable fascia as shown (Fig. A). Secure using 2" finish nails into rafter ends. Repeat Step 1 on opposite eave.
  • Page 43 DOORS PARTS REQUIRED: 3" (7,6 cm) x4 1 x 3 x 5" (2,5 x 7,6 x 12,7 cm) 1-1/2 x 2-1/2 x 69" (3,8 x 7,6 x 175,3 cm) 1-1/4" (3,2 cm) x2 TEMPORARY SUPPORT HINT: Look for 3/8" SPACER attached to doors. Left Door Right Door BEGIN...
  • Page 44 DOORS PARTS REQUIRED: 3" (7,6 cm) 1-1/2 x 2-1/2 x 69" (3,8 x 6,3 x 175,3 cm) Attach temporary support OO as a ledger board flush under wall panels for doors to rest on, using three 3" screws (Fig. A) . Carefully cut bottom wall frame 2 x 4 flush with door frame using a saw (Fig.
  • Page 45 DOOR TRIM PARTS REQUIRED: 3/4" (1,9 cm) 2" (5,1 cm) 19/32 x 3 x 26-5/8" (1,5 x 7,6 x 67,6 cm) 19/32 x 3 x 50-1/4" (1,5 x 7,6 x 127,6 cm) 19/32 x 3 x 50-1/4" (1,5 x 7,6 x 127,6 cm) BEGIN Secure door trim from inside using 3/4"...
  • Page 46 DOOR TRIM PARTS REQUIRED: 3/4" (1,9 cm) x11 3/4" (1,9 cm) Bagged separately / special coating 19/32 x 3 x 26-5/8" (1,5 x 7,6 x 67,6 cm) 64" Metal Threshold Position horizontal door rails AH onto outside of doors. Measure, mark and hold. Secure AH using 3/4"...
  • Page 47 DOOR STIFFENERS PARTS REQUIRED: 2" (5,1 cm) 1-1/2 x 2-1/2 x 69" (3,8 x 6,3 x 175,3 cm) BEGIN Center OO vertically on the left door in the door opening flush with the edge of door (Fig. A). Secure using (5) 2" screws through outside trim into OO (Fig. B) Repeat Steps 1-2 to install OO on right door.
  • Page 48: Door Hardware

    DOOR HARDWARE PARTS REQUIRED: 1/2" (13 mm) Drill Bit 1/4" (6 mm) Drill Bit BEGIN Measure and mark location of hole on outside of right door as shown (Fig. A) . Pre-drill hole with 1/4" drill. Re-drill hole with 1/2" drill (Fig. B) . Keep drilled hole square to trim to avoid breaking edge of 1-1/2"...
  • Page 49: Right Door

    DOOR HARDWARE PARTS REQUIRED: 3-Point Door Locking Mechanism Handle (locking) with Screws 1-1/4” x2 3/4” Tech Screw with drill point 1-1/4” x8 1/2" (13 mm) Drill Bit 1-1/4” x2 1/4" (6 mm) Drill Bit Secure backplate with 1" screws and handle with 1-1/4" screws as shown. RIGHT DOOR Screw Backplate 1/2” DRILL THROUGH 1-1/4" Wood Screw 1-1/4" Pre drill for Pan Head screws.
  • Page 50 DOOR HARDWARE See following pages for mounting locations of brackets and plates. Plate Washer 1-1/4" Pan Head Screw UPPER BRACKET 3/4" Tech Screw (with offset) Orient bracket as shown. Washer 3/4" Tech Screw Washer LOWER BRACKET (without offset) Orient bracket as shown. 1-1/4" Pan Head Screw Washer Plate...
  • Page 51 DOOR HARDWARE TOP of Door 2-1/4" Weatherstrip RIGHT DOOR LEFT DOOR Make sure rods are straight up and down when locating brackets. IMPORTANT! This rod to edge of weatherstrip 2-1/4" BOTTOM of Door...
  • Page 52 DOOR HARDWARE Drill with 3/8" bit PLATE to 2" depth. FRAMING Align Plates with vertical rod points. Drill-thru with 3/8" drill bit to 2" depth into header and floor. VERTICAL RODS FLOOR PLATE...
  • Page 53 CORNER TRIM PARTS REQUIRED: 2" (5,1 cm) 3/8 x 1-3/4 x 82-1/2" (1 x 4,4 x 209,6 cm) 3/8 x 1-3/4 x 81-7/8" (1 x 4,4 x 208 cm) ¸ BEGIN Attach one 81-7/8" trim board flush under soffit panel and against eave wall (Fig. A, B) using one 2"...
  • Page 54 LOFT PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 23-7/8" (5,1 x 10,2 x 60,6 cm) 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) NOTE: Build the loft, shelf and work bench on the gable wall farthest from the door location. ¸...
  • Page 55 LOFT PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 23-7/8" (5,1 x 10,2 x 60,6 cm) (NOT ACTUAL SIZE) 3/8" x5-1/2" (1 cm x 14 cm) 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) Hex Bolt 3/8" (1 cm) Flat Washer Pre-Assembled Loft Joist 3/8"...
  • Page 56 LOFT PARTS REQUIRED: 2" (5,1 cm) 23-7/8" x 96" (60,6 x 243,8cm) Install loft panel centered over loft joists. Secure with 2" (5,1 cm) nails 8" (20,3 cm) apart. There will be a gap of approximately 8-1/2" on either side. 8 "...
  • Page 57 SHELVING PARTS REQUIRED: 2" (5,1 cm) 3/8 x 8 x 12-1/2" (1 x 20,3 x 31,8 cm) 2 x 3 x10-1/8" (5,1 x 7,6 x 25,7 cm) BEGIN Secure AE to bracket panels using three 2" (5,1 cm) nails. Assemble 6 shelf supports as shown;...
  • Page 58 SHELVING PARTS REQUIRED: 2" (5,1 cm) 7/16 x 11-7/8 x 96" (1,1 x 30,2 x 243,8 cm) 7/16 x 11-7/8 x 23-7/8" (1,1 x 30,2 x 60,6 cm) 1 x 4 x 96" (2,5 x 10,2 x 243,8 cm) 1 x 4 x 23-7/8" (2,5 x 10,2 x 60,6 cm) Install shelf panels centered over shelf supports.
  • Page 59: Work Bench

    WORK BENCH PARTS REQUIRED: 2" (5,1 cm) 2 x 3 x 19" (5,1 x 7,6 x 48,3 cm) 3/8 x 14-1/4 x 22-1/4" (1 x 36,2 x 56,5 cm) BEGIN Secure LR to bracket panels using three 2" (5,1 cm) nails. Assemble 6 shelf supports as shown; 5 right-side, 1 left-side.
  • Page 60 WORK BENCH PARTS REQUIRED: 2" (5,1 cm) 7/16 x 20-3/4 x 92-1/2" (1,1 x 52,7 x 235 cm) 7/16 x 20-3/4 x 20-1/2" (1,1 x 52,7 x 52,1 cm) 1 x 4 x 96" (2,5 x 10,2 x 243,8 cm) 1 x 4 x 23-7/8"...
  • Page 61 COLLAR TIE PARTS REQUIRED: 2" (5,1 cm) 1 x 3 x 72" (2,5 x 7,6 x 182,9 cm) BEGIN Position and level collar tie on third rafter from loft. HINT: For best appearance install collar tie on rafter facing away from door opening. Attach with 2"...
  • Page 62 GABLE VENTS PARTS REQUIRED: #8 x 1" (2,5 cm) Pan Head Screws #15021 ¸ BEGIN Locate vent in the gable wall as shown. Secure using 1" (2,5 cm) screws. Repeat Steps 1-2 to install on the other gable wall. #8 x 1" (2,5 cm) Pan Head Screws FINISH You have finished installing your vents.
  • Page 63 WINDOW SHUTTERS PARTS REQUIRED: 5/8 x 3 x 8" (1,6 x 7,6 x 20 cm) 5/8 x 3 x 21" (1,6 x 7,6 x 53,3 cm) 1" (2,5 cm) 5/8 x 3 x 21" (1,6 x 7,6 x 53,3 cm) 5/8 x 3 x 30-1/8"...
  • Page 64 WINDOW & SHUTTERS PARTS REQUIRED: 1-1/4" (3,2 cm) Window 22-1/2" x 29-3/4" (57,1 x 75,6 cm) BEGIN Mark center of window frame as shown. CENTER Seal window with high-quality exterior- grade caulk before installing (Fig. A). Attach window using four 1-1/4" (3,2 cm) screws as shown.
  • Page 65 WINDOW & SHUTTERS PARTS REQUIRED: 2" (5 cm) 3/4" (19 mm) 5/8 x 3 x 26-5/8" (1,6 x 7,6 x 67,6 cm) Mark Locate one shutter centered on marks as shown. CENTER CENTER Attach one shutter using a 2" finish nail at "dot". Nail into wall frame inside.
  • Page 66 PAINT & CAULK - NOT INCLUDED - • Use acrylic latex caulk that is paintable. Caulk at all horizontal and vertical seams, between the trim and walls, and all around the door trim. • Use a high quality exterior acrylic latex paint. When painting your building, there are a few key areas that can be easily overlooked that must be painted: •...
  • Page 67 SHINGLES - NOT INCLUDED - • Follow directions provided by manufacturer and these instructions. Familiarize yourself with a 3-Tab Shingle. Notch Notch SHINGLE NAIL PATTERN 1/2" 1" Sealing Strip 1" (1,3 cm) (2,5 cm) (2,5 cm) Half A Rain Slot Full Rain Slot NAILS NEVER DRIVE FASTENERS INTO OR ABOVE SEALING STRIPS. BEGIN Install first starter row upside down and color up with a 1" overhang at back and bottom of roof panel. Use (4) nails per shingle. Starter row must be straight and level all the way across with lower edge of roof deck.
  • Page 68 SHINGLES continued... Beginning at front of shed, install first row of shingles with notch at 1" past roof edge or flush with drip edge. Roof Deck FRONT OF BACK OF SHED SHED 1" (2,5 cm) Flush with starter row. Notch - or - Drip Edge Flush with starter row.
  • Page 69 SHINGLES continued... Continue installing rows of shingles to the peak. At the peak make sure there is a maximum of 5" or less to the rain slot, as shown below. If shingles overlap at ridge cut to peak with a utility knife. 5"...
  • Page 70 SHINGLES - RIDGE CAP • You will finish off the top of the roof with a ridge cap made from shingles. BEGIN Cut shingles into THREE pieces. Hint: Use cut-off pieces first. 2" 2" (5 cm) (5 cm 2" 2" 2"...
  • Page 71 SHINGLES - RIDGE CAP continued... Continue installing ridge cap to back of roof. Make sure there is 4" between the shingle-color and edge of shingles. 4" (10 cm) Trim cap off flush to shingles When you have 4" minimum of shingle color cut one piece to cap your roof. Cut at top of rain slot.
  • Page 72 WARRANTY REGISTRATION Please complete your warranty registration to properly validate your warranty. Register your product online at:www.OnlineWarranty.net. LIMITED CONDITIONAL WARRANTY* Backyard Storage Solutions, LLC warrants the following: Every product is warranted from defects in workmanship and manufacturing for 1 year. All accessories, hardware and metal components are warranted for 2 years.

Table of Contents