layout. Incorrect wiring could result in fire, damage or malfunctions.
Tighten the terminal screw with the specified torque. If the screws of terminal are loose, it could result in
short circuit, fire, malfunctions. FG Terminal must be used a dedicated ground. Not doing so could result in
malfunctions.
a. Grounding should be the Class 3 grounding. The cable for grounding should be more than 4㎟.
b. grounding point be closed to the products and make short the distance to the ground cable if possible. Please see
below.

Installation Precaution

Do not install the location which exceeds allowed temperature. Product can be damaged or shorten the life.
Especially Install environment as below should be avoided.
Do not Install product to the place which the ambient temperature is out of limits, from 0℃ to 60℃ or on
the surface of control board which high pressure equipment is installed.
Do not install to the place where strong shock or vibration continuously have impacted on product.
The space between back of product and back of control board must be more than 100mm for maintenance
and ventilation.
Do not storage and operate in the place in direct sunlight. By the strong ultraviolet rays can degrade the quality
of LCD Displays.

Disposal Precaution

When you dispose of product, please treat it as industrial waste. It can create poisonous substances or
explosion.

Cell Type Battery Specifications and Exchange

If a "CMOS CHECKSUM ERROR" occurs during booting, the BIOS setup can not be saved due to the
exhaustion of the CMOS battery, so users should replace the button battery that is fixed in the product.
Item
Battery Voltage
Battery Model
Battery lifetime
Image
* Depending on the model specifications are subject to change.
All field-wiring connections to this unit shall be from Limited Voltage / Limited below 24Vdc isolated
secondary source with an output fuse, or Class 2.
M
I Corporation
2
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
Content
DC 3V
CR2032(lithium Battery)
About 3 years (In case of ambient temperature 25℃)