Chapter 5. Installation

5.1 Installation Requirements

(1) To safe use of the product, keep the 100mm space between the wall and the product. And install the
cooling fan in an enclosed space to ensure performance and ventilation.
(2) TOP PC should be installed within 0 ~ 60°C(relative-humidity 0%) or 0~40°C(relative-humidity less than 95%,
(Non-Condensing)), otherwise the screen may be changed or cause malfunction and damage.
(3) Be sure that heat from surrounding equipment does not cause TOP PC to exceed its standard operating
temperature.
(4) When you don't see within 30°, you may not see clearly.
(5) When installing the TOP PC in a slanted position, TOP PC screen should not incline more than 30°
5.2 Installation Procedure
For mounting product to the control panel, it should be recommended following below items.
Panel Cut-out
5.2.1
Make a panel cut which product is mounted and insert the TOP PC to the panel form the front side.
(1) The Size of Panel Cut (Mounting Place)
Making the Panel Cut (Mounting Size) per each TOP PC Series as below Table, Before Installation.
Model
TOP-PCVIEW10
TOP-PCVIEW12
TOP-PCVIEW15
TOP-PCVIEW17
TOP-PCVIEW19
M
I Corporation
2
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
IP2X
0 ~ 60°C
0 ~ 60°C
A(mm)
260.0
306.0
355.0
400.0
479.0
IP65
B(mm)
R(mm)
202.0
Max. 5.0
247.0
Max. 5.0
286.0
Max. 5.0
334.0
Max. 2.0
298.0
Max. 2.0
TOP-PCVIEW Hardware Manual