Section 4 – Pre-Operation Procedures
4.1 – Installing the Charger
The TI150 Series Battery/Charger is designed to be permanently integrated into vehicles and other
equipment. Mounting is accomplished by using the four holes in the base of the unit. The holes are
0.190" (4.826 mm) and will accept up to 10-24 size bolts or M5 in metric. Once the TI150 is securely
mounted to the vehicle or other equipment, proceed to the next step.
4.2 – Attaching AC Power
CAUTION
WARNING
Failure to use proper grounding can create a shock hazard. Depending on geographic location, the
standard 220 Vac 50 Hz power cord may require a foreign plug adapter for compatibility. Use only
adapters with a proper grounding mechanism.
Proper Ground
Before plugging the TI150 into ac power check the dc output cable to make sure the two output wires are
not touching (by disconnecting quick disconnect to prevent shorting).
12
Unit damage may occur if the wrong voltage is used.
Make sure the line voltage is appropriate for your specific
model. See Model numbers in Figure 4.3.2
Failure to use proper grounding can create a shock haz-
ard. Please follow proper wiring procedures below.
Figure 4.2.1– Illustrations of proper and improper grounding
Proper Ground
TI150 Series Hardwired Battery Charger/Conditioner
Improper Ground