ER21
Over temperature
ER22
Internal error inside TC
ER31
Configurations inside Tou-
ch Control and induction
are incongruent
ER36
Internal error inside TC
ER42
Secondary power supply
implausible
ER47
No communication to at
least one LIN subscriber
Cooktop switches
Temperature sensor
off
on TC has detected a
temperature > 85° C
Cooktop switches
off after3.5-7.5
sec.
ER31 is displayed
The configuration data
continuosly
inside the induction
generator is different
from the configuration
Cooktop switches
off
12V or 5V too high / too low
ER47 is displayed
LIN cable damaged
continuously
No power voltage sup-
ply for LIN subscriber
LIN subscriber de-
31
Let the cooktop cool
down (error disap-
pears if temperature
is <75°C). Contact
technical support.
-
Contact technical
Download configu-
ration. If error is still
occurring, replace TC.
If error is still occur-
inside the TC
ring, contact technical
-
Contact technical
fective
EN
support.
support..
Replace TC
support.