H2Tu-C-231 List 1E Pairgain Config Screen Options - ADC PAIRGAIN HiGain HDSL2 Manual

Hide thumbs Also See for PAIRGAIN HiGain HDSL2:
Table of Contents

Advertisement

152-231-115-03, Revision 03
Table 5. H2TU-C-231 List 1E Standard Config Screen Options (Cont.)
Front-panel
System Settings
Display
Screen Options
Code
H2TU-R TOS
TLOS
Loopback
Network
NLBP
Loopback Pattern
Table 6. H2TU-C-231 List 1E PairGain Config Screen Options
Front-panel
System Settings
Display
Screen Options
Code
Line Power Feed
PWRF
Remote
RTPV
Provisioning
Bipolar Violation
BPVT
Transparency
(See
"Bipolar
Violation
Transparency
(BPVT) Option"
on page
23.)
HDSL2 BER
HBER
Threshold
(See
"HDSL2 BER
Threshold (HBER)
Option" on
page 23
and
"System Alarm
Output Pins" on
page
61.)
DS1 BER
DBER
Threshold
(See
"DS1 BER
(DBER) Option"
on page
23.)
Special Loopback
SPLB
Mode
SmartJack
LPBK
Loopback
H2TU-C-231 List 1E
Selection
Description
ENA
Enables a logic loopback at the H2TU-R when an LOS occurs at its DS1 input,
if enabled at the H2TU-R. For priority resolution, see
DIS
Disables Transmit Loss of Signal (TLOS) logic loopback.
AIS
Enables the H2TU-R to transmit an AIS towards CI for any network loopback.
For priority resolution, see
LOS
Enables the H2TU-R to transmit an LOS towards CI for any network loopback.
Selection
Description
OFF
Disables powering to the HDSL2 pair.
ON
Keeps the HDSL2 line voltage at nominal -185 Vdc.
ENA
Enables remote provisioning.
DIS
Disables remote provisioning.
ENA
Enables BPVs and HDSL2 CRC errors at the DS1 input to be converted into
DS1 BPVs at the DS1 output at the distant end. This makes HiGain HDSL2
transparent to BPVs.
DIS
Disables BPV Transparency.
1E-6
System alarm relay contact closes and the Status LED flashes red when the
Block Error Rate exceeds 10
Bit Error Rate.)
1E-7
System alarm relay contact closes and the Status LED flashes red when BER
exceeds 10
NONE
Prevents generation of a system alarm due to BER.
ENA
Enables the fixed 24-hour DS1 BER threshold.
DIS
Prevents the generation of a system alarm due to DS1 BER.
GNLB
Configures the HiGain HDSL2 system to respond to the generic inband
loopback codes.
A2LB
Configures the HiGain HDSL2 system to respond to the inband loopback
codes of the Teltrend addressable repeater.
A3LB
Configures the HiGain HDSL2 system to respond to the inband loopback
codes of the Wescom addressable repeater.
A4LB
Configures the HiGain HDSL2 system to respond to the inband loopback
codes of the Wescom Mod 1 addressable repeater.
ENA
Enables the HiGain HDSL2 system to recognize all inband SmartJack (SMJK)
loopback commands.
DIS
Configures the HiGain HDSL2 system to ignore all inband SmartJack
loopback commands.
April 21, 2000
Figure 24 on page
-6
. (Block Error Rate is based on the definition of
-7
.
Provisioning
Figure 24 on page
47.
47.
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

H2tu-c-231