The metallic cables which interface with digital extensions (T1 and HDSL -
terminated with either 3M 710 or 3M 4005 connectors.
If these metallic cables are terminated with 710-SC1-25 splicing modules, the mating cables are to be terminated
with the 710-BC1-25 bridging modules (using an 890-type tool) prior to dressing the cable into the field cabinet.
If the field cabinet cables are terminated with 3M 4005 or other connector type, refer to connector manufacturer's
instructions.
1. Match and route the OSP digital pairs with the associated field cabinet pairs.
2. Pull the OSP and field cabinet pairs to the splicing tool and splice, trimming any excess cable.
3. Shield the OSP digital pairs (T1 and HDSL) by wrapping with one layer of overlapped AT-7165 aluminum
tape or heavy-duty aluminum foil.
4. Dress the spliced pairs and secure to the tie bars with wire ties.
Ensure that the A (incoming) and B (outgoing) digital pair cables are dressed apart from each other. Also,
ensure that the cables are secured within the splice chamber so the splice chamber cover can be replaced
and so there is no interference with the Mini Fiber Panel, if used.
5. Using wire ties, secure the OSP and field cabinet cables together as necessary.
22
S
T
PLICING AND
ERMINATION
Table 8 on page
23) are typically
ADC Telecommunications, Inc.
July 19, 2004