LTPH-TP-1024-02, Issue 2
1
Connect a standard 9-pin terminal cable to the craft port
page
12) on the HRU front panel. (For a pinout diagram of the craft port,
refer to
"Craft Port" on page
2
Connect the other end of the cable to the serial COM port on the
maintenance terminal.
3
Start a terminal emulation program such as ProComm (emulating a
VT-100 terminal).
4
Configure the maintenance terminal for the following communication
settings:
1200 to 9600 baud (9600 baud is recommended)
no parity
8 data bits
1 stop bit
Hardware Flow Control set to NONE
If using the Microsoft Windows terminal emulation program,
from the Settings, Terminal Preference menu, deselect Show
Scroll Bars and Use Function, Arrow, and Ctrl Keys for
Windows.
L
O
OGGING
To log on and access the Remote Terminal Main Menu screens using the
maintenance terminal:
1
Press the
display the Remote Login screen.
2
Press the
Maintenance Terminal screens (or press
Performance Monitoring Menu shown on
The Remote Terminal Main Menu items (see
are replications of the HLU screens. Depending on the HLU
attached to the HRU-402 List 4, remote provisioning may be
available. Refer to the HLU technical practice for details.
HRU-402 List 4
O
N AND
FF
SPACEBAR
several times to activate the autobaud feature and
key to perform a remote login to the HiGain
January 3, 2001
35.)
TAB
to access the HRU-402
page
Remote Login
(Figure 5 on
18).
Table 5 on page
15)