Table 10. User Options for the Set HiGain Configuration Screen
Press
To Set Option
Key
CI signal output
A
level
Report message
B
generation
Frame format
C
conversion
Reset PM
F
registers
Reset Blockage
G
Indicator
registers
Reset
H
Sectionalizer
registers
32
Options
Description
DSX-1 or NI
Selects the T1 equalizer to DSX-1 setting or
the Network Interface setting.
Selects the type of performance reporting
messages.
NONE
No PRM generation. The data link from the
CPE is passed through transparently.
SPRM
The HRU monitors incoming datalink traffic
and modifies the PRM to a SPRM. If there is
no PRM within 5 seconds of startup or a LOS
condition exists, the HRU generates its own
SPRM. Other High-level Data Link Control
(HDLC) messages and Bit-Oriented
Messages (BOMs) are passed on
transparently.
SPRM + NPRM
In addition to the SPRM message, the HRU
adds an NPRM.
NPRM
The HRU only generates NPRM, however, if
there is a PRM from the customer, the HRU
tags on an NPRM. Any HDLC traffic from the
CPE (including ATT PUB and BOMs) is
passed on.
Disable
Disables SF to ESF frame format conversion
at the network interface.
Auto
Remote unit passes ESF through or converts
SF to ESF if it detects ESF coming from the
network. At the same time, it converts a
network ESF signal back to SF if it detects SF
coming from the CPE. Auto Conversion
enables the remote unit to transmit PRM back
to the network to aid in network
troubleshooting.
No or Pending
The "Pending" selection resets the
24 hour/15 min and 7 day/24 hour PM
registers to zero.
No or Pending
The "Pending" selection resets all blockage
events to zero.
No or Pending
The "Pending" selection resets any and all
sectionalized events stored in the registers to
zero.