LTPH-SM-1052-04
5
From the Shelf Options screen, press
6
Confirm that Baud Rate is set at 9600. If the baud rate is not set at 9600, press
baud.
7
Confirm that Character Size is set at 8. If the character size is not set at 8, press
bits.
8
Confirm that Parity Bits is set at None. If the parity bits is not set at None, press
None.
9
Confirm that Stop Bits is set to 1. If the stop bits is not set to 1, press
10
Confirm that User Type is set to X.25 (Interactive Mode) or X.25NMA (NMA Mode). To change the user
type, press
E
, then press
X
11
Press
to exit and return to the Shelf Options screen.
12
From the Shelf Options screen, press
prompting the user to reset the HMU if changes have been made to any of the shelf options. For changes to
take effect, press
For all X.25 connections to the HMU through the OS port, the HMU behaves in either Interactive
Mode or NMA Mode, depending on the User Type setting (see

X.25 Configuration Using TL1 Commands

The following steps describe how to configure the OS port for X.25 using TL1 commands.
1
Connect to the HMU through either the Serial or Ethernet port. If connected to the Serial port, use a PC
running HyperTerminal; if connected to the Ethernet port, use a Telnet session.
2
Log on to the HMU with the following ACT-USER command:
ACT-USER :: SUPERUSER ::: PUBLIC#1;
3
Configure the OS port for X.25 in Interactive Mode or NMA Mode using the following applicable ED-PORT
commands:
For Interactive Mode:
ED-PORT::PORT-2::::USERTYPE=X.25:MA;
For NMA Mode:
ED-PORT::PORT-2::::USERTYPE=X.25NMA:MA;
The HMU responds with the following four lines of text:
Line 1: contains the Target Identifier followed by the Date and Time
Line 2: M 0 COMPLD
Line 3: /* NOTE: Changes will not take effect until HMU has been cycled.*/
Line 4: ;
4
For the new configuration to take effect, reset the HMU using the following TL1 command:
INIT-SYS::HMU:::0;
The HMU responds with the following message:
"INIT-SYS: System will be reset now, please wait . . ."
HMS-358 List 5 and List 6
P
, then press
4
(Interactive Mode) or
X
to exit and return to the Shelf Status screen. A message appears
Y
to reset the system. The OS port is now configured for X.25.
Appendix B - HMU Configuration for X.25 and Ethernet Connections
2
to select the OS port. The port settings display
D
5
(NMA Mode).
July 14, 2002
A
, then press
1
to select 9600
B
, then press
2
to select 8
C
, then press
1
to select
, then press
1
to select 1.
Step 10
above).