1. Remove the AC power cable from the power supply's connector.
2. Grasping the handle of the failed power supply, use the Release Lever to release the locking
mechanism and slide the power supply out of the switch.
Figure 1 Replacing a failed power supply
Label
1
2
3. Insert the new power supply. Slide it all the way in until the locking mechanism clicks into place.
Figure 2 Inserting a power supply into the bay
4. Connect the AC power cable to the new power supply's connector.