3. Switch On/Off and Display
Switch On/Off
System shall be turned on in the correct sequence to avoid any damage.
Figure 3.1 LED Display
LED Display
In normal condition, LED display indicates the SOC as the figure below:
LED Ring
Standby:
Green light flickering 1 s
Work:
Green light flickering 10s
______________________________________________________________________
Switch On/Off and Display
Switch on:
Pressing the power button for about 2-4
seconds. The BMS will start up. The LED
display and power button will light up as
well.
Switch off:
Pressing the power button for >5
seconds, Turns off battery modules.
SOC
Alpha ESS Co., Ltd.
Your Smart Energy
Description
SOC<20%
The first light 3S flashes once
20%=<SOC<25%
The first grid light is always on
25%=<SOC<45%
The second light 3S flashes once
45%=<SOC<50%
The second light is always on
50%=<SOC<70%
The third light 3S flashes once
Battery state
70%=<SOC<75%
The third light is always on
Page 19 of 29