Alpha ESS SMILE-BAT-G3-10.1P Instruction Manual page 24

Energy storage battery
Table of Contents

Advertisement

Your Smart Energy
Error 09
Error 10
Error 11
Error 12
Error 13
Error 14
Error 15
NOTE:
In the case of parallel mode or work mode, if Protection 09 appears and the power
button is pressed 5 times within 10 seconds, the BMS will be forced to turn on MOS of
discharge so that the battery voltage can be detected by the inverter and the battery can
be charged.
______________________________________________________________________
Page 22 of 29
Error and Protection Code
(slave)
SN missing
LMU
Disconnect
(master)
Software
version
inconsistent
Multi master
MOS
over
temperature
Insulation fault
Total
voltage
fault
Alpha ESS Co., Ltd.
Enter the serial number, restart
the system or call in for repair.
Reconnect the communication
cable
Call installation for repair.
Restart all batteries
Power off the battery and turn on
the battery after 30-40 minutes