Download Print this page

Installation Instructions - Intermec EasyCoder PF2i Install Manual

Thermal printhead
Hide thumbs Also See for EasyCoder PF2i:

Advertisement

Installation Instructions

(For illustrated instructions, refer to the printer's User's Guide).
Switch off the power to the printer.
1
Open the side door (and the front door, if any).
2
Turn the printhead lift lever clockwise to raise the printhead.
3
Remove any remaining media and transfer ribbon.
4
Hold the pressure arm and press down the printhead bracket so it
5
comes free from the magnet in the pressure arm.
Disconnect the printhead bracket by twisting it out of the print
6
mechanism and pull it out as far as the cables allow.
Disconnect the cables from the printhead. Note the snap-lock on the
7
inner connector. Pull at the connectors—not at the cables.
Check that the label on the new printhead corresponds to the label
8
on the old one and connect the two cables to the replacement print-
head.
Fit the printhead so the "fi ngers" engage the headlift shaft. Check
9
that the cables run freely.
Turn the printhead lift lever counterclockwise so the magnet engages
10
the printhead bracket.
Switch on the power, so the printer can reset itself to the characteris-
11
tics of the new printhead.
Load a new supply of media and ribbon as described in the printer's
12
User's Guide.
Printhead Installation Instructions
EasyCoder PF2i, PF4i, PF4i Compact Industrial, and PM4i
3

Advertisement

loading