Connection; Connection Points - Bosch rexroth IndraDrive Mi KMV03 Instruction Manual

Distributed supply unit/distributed mains filter
Hide thumbs Also See for rexroth IndraDrive Mi KMV03:
Table of Contents

Advertisement

IndraDrive Mi KMV03 Distributed Supply Unit KNK03 Distrib‐
uted Mains Filter
4.5

Connection

4.5.1

Connection points

WARNING
Do not remove connectors when the component has been powered. Do not
plug in connectors when the component has been powered.
Wait at least 30 minutes after switching off the supply voltages to allow dis‐
charging.
Figure
1)
RKH0800 cable connects KMV to KNK
2)
RKH0801 cable connects KMV to KNK
3)
RKB0054 cable
Tab. 4-2:
KMV03 connection points
High electrical voltage! Danger to life by elec‐
tric shock!
Element Significance
X37
Digital inputs/outputs
X38
X103.1
Hybrid cable
X103.2
X118
External communication
X119
X141
-
Mains voltage
XD1
1)
XD10
Control voltage
KMV03.1R-Wxxxx:
XD13
3)
Fan
Mains choke temperature
XG3
2)
contact
Mains voltage synchroniza‐
XG14
2)
tion
Mains contactor control and
XG34
1)
feedback contacts (KNK03)
Second connection point of
equipment grounding con‐
ductor
R911374765_Edition 01 Bosch Rexroth AG
19/29
Instructions for use