Bosch rexroth IndraDrive Mi KMV03 Instruction Manual page 24

Distributed supply unit/distributed mains filter
Hide thumbs Also See for rexroth IndraDrive Mi KMV03:
Table of Contents

Advertisement

20/29
Instructions for use
Bosch Rexroth AG R911374765_Edition 01
IndraDrive Mi KMV03 Distributed Supply Unit KNK03 Distrib‐
Figure
1)
Coding pins prevent the connectors XD1 and XD1.2 from being
incorrectly plugged
2)
RKH0800 cable connects KMV to KNK
3)
RKH0801 cable connects KMV to KNK
4)
RKB0054 cable
Tab. 4-3:
KNK03 connection points
Connection point
Cable
X37, X38
RKS0010
X103.1, X103.2
RKH0xxx
X1x8, X1x9
RKB0043, RKB0044
XD1 (KNK03)
Customer assembles the cable (HAS05.1-019 accessories re‐
quired)
XD1 (KMV03),
RKH0800
XD1.2 (KNK03)
XG34
XG3
RKH0801
XG14
XD10
Customer assembles the cable (HAS05.1-020 accessories re‐
quired)
XD13
RKB0054
1)
Ready-made hybrid cable depending on the desired outgoing
directions of the hybrid cable at the connection points X103.1
and X103.2
Tab. 4-4:
Cable
Element Significance
XD1
Mains voltage supply input
Output to load KMV03 (XD1,
XD1.2
2)
mains voltage)
KNK03.1A-NR-Wxxxx:
XD13
4)
Fan
Output to load KMV03
XG14
3)
(XG14, mains voltage syn‐
chronization)
Mains choke temperature
XG3
3)
contact
Mains contactor control and
XG34
2)
feedback contacts
Second connection point of
equipment grounding con‐
ductor
1)
uted Mains Filter
1)
1)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth indradrive mi knk03

Table of Contents