Bosch rexroth IndraDrive Mi KMV03 Instruction Manual page 25

Distributed supply unit/distributed mains filter
Hide thumbs Also See for rexroth IndraDrive Mi KMV03:
Table of Contents

Advertisement

IndraDrive Mi KMV03 Distributed Supply Unit KNK03 Distrib‐
uted Mains Filter
Symbols used to describe the connection points
Screw terminal
Spring terminal
block
Connection point
XD1, XD1.2
XD10
XG3
XG14
XG34
Thread
Max. connection
cross section
Tab. 4-5:
Symbols
mm
1.5 (16)
1.5 (16)
M5; 4 (12)
Tab. 4-6:
Connection points
For proper function of the motor thermal management connect the motor
thermal sensor as described in the wiring diagram. Otherwise motor overtem‐
perature sensing is not provided by the drive.
For Rexroth motors with data memory in the motor encoder, such as MSK,
the motor overload protection level is set automatically while connecting the
motor to the drive. There is no adjustment necessary. Otherwise refer to the
Rexroth firmware documentation.
Stripped length
mm
2
(AWG)
6 (10)
10
6 (10)
10
10
6 (10)
10
10
-
R911374765_Edition 01 Bosch Rexroth AG
21/29
Instructions for use
Max. tightening torque
Nm
0.8
0.8
-
0.8
-
3.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth indradrive mi knk03

Table of Contents